Heating actuator, 6-gang
- Herstellernummer
- EAN
Bestellung
- Bestelleinheit
- Stück
Beschreibung
Rail mounting device, 4 rail units 6 outputs "TRIAC" with manual electronic operation and LED status indication ETS product family: Heating, A/C, Ventilation Product type: Valve Intended use Switching of electrothermal actuators for heaters or cooling ceilings Installation in distribution boxes on DIN rail according to EN 60715 Product characteristics Switching operation or PWM operation Actuators with characteristics "normally open" or "normally closed" can be controlled Valve drives for 230 V or 24 V controllable Outputs can be operated manually, construction site mode Feedback in manual mode and in bus mode Disabling of individual outputs manually or via bus Overload-protected, short circuit-protected; error indication with LED Protection against jamming valves Forced position Various setpoints for forced position or emergency operation in case of bus failure for summer or winter Cyclical monitoring of the input signals can be parameterised Feedback via bus, e.g. in case of mains failure, overload or sensor failure
Ausschreibungstext
Heating actuator 6-gang KNX heating actuator, 6-gang Intended use ■ Switching of electrothermal actuators for heaters or cooling ceilings ■ Installation in distribution boxes on DIN rail according to EN 60715 Product characteristics ■ Switching operation or PWM operation ■ Actuators with characteristics "normally open" or "normally closed" can be controlled ■ Valve drives for 230 V or 24 V controllable ■ Outputs can be operated manually, construction site mode ■ Feedback in manual mode and in bus mode ■ Disabling of individual outputs manually or via bus ■ Overload-protected, short circuit-protected; error indication with LED ■ Protection against jamming valves ■ Forced position ■ Various setpoints for forced position or emergency operation in case of bus failure for summer or winter ■ Cyclical monitoring of the input signals can be parameterised ■ Feedback via bus, e.g. in case of mains failure, overload or sensor failure Technical data Rated voltage: AC 110 ... 230 V ~, 50/60 Hz Stand-by power: max. 0.4 W Power loss: max. 1 W KNX medium: TP 256 Rated voltage KNX: DC 21 ... 32 V SELV Power consumption KNX: max. 250 mW Ambient temperature: −5 ... +45 °C Storage/transport temperature: −25 ... +70 °C Heating outputs Contact type: semiconductor (triac), ε Switching voltage: AC 24 / 230 V ~ Mains frequency: 50/60 Hz Switching current: 5 ... 160 mA Switch-on current: max. 1.5 A (2 s) Switch-on current: max. 0.3 A (2 min) Number of drives per output 230 V drives: max. 4 24 V drives: max. 2 Mounting width: 72 mm (4 rail units) Connection, outputs Connection mode: screw terminals single wire: 1 x 0.5 ... 4 mm2 stranded without ferrule: 1 x 0.5 ... 4 mm2 stranded with ferrule: 1 x 0.5 ... 2.5 mm2 Manufacturer: JUNG Ref.-no.: 2336 REG HZ HE
Technische Daten
ETIM-Klasse: Bussystem-Heizungsaktor (EC001586)
Communication
- Bussystem KNX
- -
- Bussystem KNX-Funk
- -
- Bussystem Funkbus
- -
- Bussystem LON
- -
- Bussystem Powernet
- -
- Andere Bussysteme
- -
Options
- Funk bidirektional
- -
- Busmodul abnehmbar
- -
- Stellgröße stetig
- -
- Stellgröße schaltend
- -
- Handschaltung
- -
Mounting/installation
- Montageart
- -
Measurements
- Breite in Teilungseinheiten
- 4
- Min. Tiefe der Gerätedose
- - mm
- Anzahl der binären Eingänge
- -
Protection
- Ventilschutzfunktion
- -
- Schutzart (IP)
- IP20
Electrical
- Max. Schaltstrom (Ohmsche Last)
- - A
- Max. Ausgangsstrom
- - A
- Schaltspannung
- - V
Connection
- Anzahl der Ausgänge
- 6
Logistik
- Ursprungsland
- Deutschland
- Zolltarifnummer
- 85371098
Verpackung
| Verpackungseinheit | Menge | GTIN | Bruttogewicht | Abmessungen (L × B × T) |
|---|---|---|---|---|
| Paket | 1 | — | 0,285 kg | 95 × 96 × 77 mm |