3 binary inputs 1 output "TRIAC" ETS product family: Heating, A/C, Ventilation Product type: Valve Intended use Switching of electrothermal actuators Installation in flush box according to DIN 49073 Connection with enclosed terminals   Product characteristics Three binary inputs for potential-free contacts, usable as extension inputs for local operation Supply via bus, no additional power supply necessary Switching operation or PWM operation Actuators with characteristics "normally open" or "normally closed" can be controlled Overload-protected, short circuit-protected Protection against jamming valves Forced position Cyclical monitoring of the input signals can be parameterised   PWM operation: electrothermal actuators only have the positions Open and Closed. In PWM operation, switch-on and switch-off during the drive’s cycle time achieves an almost constant behaviour.

Ausschreibungstext

Flush-mounted heating actuator, 1-gang with satellite input Flush-mounted KNX heating actuator, 1-gang with satellite input Intended use ■ Switching of electrothermal actuators ■ Installation in flush box according to DIN 49073 ■ Connection with enclosed terminals Product characteristics ■ Three binary inputs for potential-free contacts, usable as extension inputs for local operation ■ Supply via bus, no additional power supply necessary ■ Switching operation or PWM operation ■ Actuators with characteristics "normally open" or "normally closed" can be controlled ■ Overload-protected, short circuit-protected ■ Protection against jamming valves ■ Forced position ■ Cyclical monitoring of the input signals can be parameterised PWM operation: electrothermal actuators only have the positions Open and Closed. In PWM operation, switch-on and switch-off during the drive’s cycle time achieves an almost constant behaviour. Technical data Rated voltage: AC 230/240 V ~, 50/60 Hz Switching voltage: AC 250 V ~ Ambient temperature: −5 ... +45 °C Storage/transport temperature: −25 ... +70 °C Heating output Contact type: semiconductor (triac), ε Switching current: 5 ... 25 mA Switch-on current: max. 600 mA (2 s) Number of drives per output: max. 2 Control cable Cable type: YY6x0.6 Input type: floating contact Total length of control cable: max. 5 m Voltage satellite inputs: approx. 5 V Dimensions (Ø x H): 53 x 28 mm Connection Connection mode: screwles terminals single wire: 1 x 1 ... 2.5 mm2 Rated voltage KNX: DC 21 ... 32 V SELV Power consumption KNX: max. 240 mW Connection, KNX: terminal Approvals: VDE Manufacturer: JUNG Ref.-no.: 2501 HZ UP

Technische Daten

ETIM-Klasse: Bussystem-Heizungsaktor (EC001586)

Communication

Bussystem KNX
Ja
Bussystem KNX-Funk
Nein
Bussystem Funkbus
Nein
Bussystem LON
Nein
Bussystem Powernet
Nein
Andere Bussysteme
-

Options

Funk bidirektional
-
Busmodul abnehmbar
-
Stellgröße stetig
Ja
Stellgröße schaltend
Ja
Handschaltung
Nein

Mounting/installation

Montageart
Unterputz

Measurements

Breite in Teilungseinheiten
-
Min. Tiefe der Gerätedose
- mm

Connection

Busankopplung inklusive
Ja
Anzahl der Ausgänge
1
Anzahl der binären Eingänge
-

Protection

Ventilschutzfunktion
Ja
Schutzart (IP)
-

Electrical

Max. Schaltstrom (Ohmsche Last)
1.5 A
Max. Ausgangsstrom
- A
Schaltspannung
250, 250 V

Logistik

Ursprungsland
Deutschland
Zolltarifnummer
85365080

Verpackung

VerpackungseinheitMengeGTINBruttogewichtAbmessungen (L × B × T)
Paket1—0,084 kg84 × 82 × 72 mm
Karton10—0,958 kg362 × 182 × 88 mm