3 binary inputs 1 output "TRIAC" ETS product family: Heating, A/C, Ventilation Product type: Valve Intended use Switching of electrothermal actuators Installation in flush box according to DIN 49073 Connection with enclosed terminals Product characteristics Three binary inputs for potential-free contacts, usable as extension inputs for local operation Supply via bus, no additional power supply necessary Switching operation or PWM operation Actuators with characteristics "normally open" or "normally closed" can be controlled Overload-protected, short circuit-protected Protection against jamming valves Forced position Cyclical monitoring of the input signals can be parameterised PWM operation: electrothermal actuators only have the positions Open and Closed. In PWM operation, switch-on and switch-off during the drive’s cycle time achieves an almost constant behaviour.
Ausschreibungstext
Flush-mounted heating actuator, 1-gang with satellite input Flush-mounted KNX heating actuator, 1-gang with satellite input Intended use ■ Switching of electrothermal actuators ■ Installation in flush box according to DIN 49073 ■ Connection with enclosed terminals Product characteristics ■ Three binary inputs for potential-free contacts, usable as extension inputs for local operation ■ Supply via bus, no additional power supply necessary ■ Switching operation or PWM operation ■ Actuators with characteristics "normally open" or "normally closed" can be controlled ■ Overload-protected, short circuit-protected ■ Protection against jamming valves ■ Forced position ■ Cyclical monitoring of the input signals can be parameterised PWM operation: electrothermal actuators only have the positions Open and Closed. In PWM operation, switch-on and switch-off during the drive’s cycle time achieves an almost constant behaviour. Technical data Rated voltage: AC 230/240 V ~, 50/60 Hz Switching voltage: AC 250 V ~ Ambient temperature: −5 ... +45 °C Storage/transport temperature: −25 ... +70 °C Heating output Contact type: semiconductor (triac), ε Switching current: 5 ... 25 mA Switch-on current: max. 600 mA (2 s) Number of drives per output: max. 2 Control cable Cable type: YY6x0.6 Input type: floating contact Total length of control cable: max. 5 m Voltage satellite inputs: approx. 5 V Dimensions (Ø x H): 53 x 28 mm Connection Connection mode: screwles terminals single wire: 1 x 1 ... 2.5 mm2 Rated voltage KNX: DC 21 ... 32 V SELV Power consumption KNX: max. 240 mW Connection, KNX: terminal Approvals: VDE Manufacturer: JUNG Ref.-no.: 2501 HZ UP
Technische Daten
ETIM-Klasse: Bussystem-Heizungsaktor (EC001586)
Communication
- Bussystem KNX
- Ja
- Bussystem KNX-Funk
- Nein
- Bussystem Funkbus
- Nein
- Bussystem LON
- Nein
- Bussystem Powernet
- Nein
- Andere Bussysteme
- -
Options
- Funk bidirektional
- -
- Busmodul abnehmbar
- -
- Stellgröße stetig
- Ja
- Stellgröße schaltend
- Ja
- Handschaltung
- Nein
Mounting/installation
- Montageart
- Unterputz
Measurements
- Breite in Teilungseinheiten
- -
- Min. Tiefe der Gerätedose
- - mm
Connection
- Busankopplung inklusive
- Ja
- Anzahl der Ausgänge
- 1
- Anzahl der binären Eingänge
- -
Protection
- Ventilschutzfunktion
- Ja
- Schutzart (IP)
- -
Electrical
- Max. Schaltstrom (Ohmsche Last)
- 1.5 A
- Max. Ausgangsstrom
- - A
- Schaltspannung
- 250, 250 V
Logistik
- Ursprungsland
- Deutschland
- Zolltarifnummer
- 85365080
Verpackung
| Verpackungseinheit | Menge | GTIN | Bruttogewicht | Abmessungen (L × B × T) |
|---|---|---|---|---|
| Paket | 1 | — | 0,084 kg | 84 × 82 × 72 mm |
| Karton | 10 | — | 0,958 kg | 362 × 182 × 88 mm |