Zum Inhalt springen
Eltracore
Noch kein Foto

Jung

Visu Pro Server, German

Herstellernummer
EAN
Preis auf AnfrageFragen Sie ein Angebot für dieses Produkt an.

Bestellung

Bestelleinheit
Stück

Beschreibung

fanless, without rotating parts including plug-in power supply Intended use Visualisation and operation of KNX systems via devices with HTML5 browser or app (iOS, Android), e.g. Smart Control (ref.-no.: SC 5 SW, SC 7.1 .., SC 10.1, SC 15.1, SC 19.1), smartphone, tablet, laptop, PC, etc. Support of KNX IP Secure and KNX Data Secure (as of version 4.5) Operation in local IP networks that support DHCP (Dynamic Host Configuration Protocol), or with static IP address (IPv4) Desktop device, mounting on DIN rail according to EN 60715 possible Max. size of the visualisation project as template in JUNG Smart Assistant Connection to KNX bus via interfaces (ref.-no.IPR 200 REG, IPS 200 REG, IPR 300 SREG, IPS 300 SREG, 20320 1S IPS R, 2131 USBS REG, 2131 USBS), not included   Product characteristics Fanless mini PC JUNG Visu Pro software pre-installed and activated Windows 10 pre-installed Quadcore Intel Celeron processor 4 GB RAM 64 GB internal memory, partly used by operating system 1 x HDMI 4 x USB 3.0 2 x LAN RJ45 (LAN 1: static IP address, LAN 2: DHCP) The visualisation can be realised with devices with a browser suitable for HTML5 (e.g. latest version of Chrome, Firefox or Safari) Access from max. 10 different clients possible Integration of Amazon Alexa voice control via MyJUNG account Integration of Google Home voice control via MyJUNG account Secure remote access via MyJUNG account Update and upgrade compatible   Process connections KNX editor/ KNX editor 2.0 instalight editor Device editor vitaLED editor XPL editor SENEC energy storage Process model Visualization editor Work sheet generator Calendar JUNG Visu Pro Starter   Data import from ETS ETS5: use of project export of ETS ETS4: use of project export of ETS ETS3: use of OPC export of ETS ETS2 version 1.1, 1.2 and 1.3: files generated by "print export" can be read Previous ETS versions: not possible

Ausschreibungstext

Visu Pro Server Visu Pro Server Intended use ■ Visualisation and operation of KNX systems via devices with HTML5 browser or app (iOS, Android), e.g. Smart Control (ref.-no.: SC 5 SW, SC 7.1 .., SC 10.1, SC 15.1, SC 19.1), smartphone, tablet, laptop, PC, etc. ■ Support of KNX IP Secure and KNX Data Secure (as of version 4.5) ■ Operation in local IP networks that support DHCP (Dynamic Host Configuration Protocol), or with static IP address (IPv4) ■ Desktop device, mounting on DIN rail according to EN 60715 possible ■ Max. size of the visualisation project as template in JUNG Smart Assistant ■ Connection to KNX bus via interfaces (ref.-no.IPR 200 REG, IPS 200 REG, IPR 300 SREG, IPS 300 SREG, 20320 1S IPS R, 2131 USBS REG, 2131 USBS), not included Product characteristics ■ Fanless mini PC ■ JUNG Visu Pro software pre-installed and activated ■ Windows 10 pre-installed ■ Quadcore Intel Celeron processor ■ 4 GB RAM ■ 64 GB internal memory, partly used by operating system ■ 1 x HDMI ■ 4 x USB 3.0 ■ 2 x LAN RJ45 (LAN 1: static IP address, LAN 2: DHCP) ■ The visualisation can be realised with devices with a browser suitable for HTML5 (e.g. latest version of Chrome, Firefox or Safari) ■ Access from max. 10 different clients possible ■ Integration of Amazon Alexa voice control via MyJUNG account ■ Integration of Google Home voice control via MyJUNG account ■ Secure remote access via MyJUNG account ■ Update and upgrade compatible Process connections ■ KNX editor/ KNX editor 2.0 ■ instalight editor ■ Device editor ■ vitaLED editor ■ XPL editor ■ SENEC energy storage ■ Process model ■ Visualization editor ■ Work sheet generator ■ Calendar ■ JUNG Visu Pro Starter Data import from ETS ETS5: use of project export of ETS ETS4: use of project export of ETS ETS3: use of OPC export of ETS ETS2 version 1.1, 1.2 and 1.3: files generated by "print export" can be read Previous ETS versions: not possible Technical data Rated voltage: DC 12 V Power consumption: typical 6 W, max. 12 W Ambient temperature: −5 ... +45 °C Storage/transport temperature: −25 ... +70 °C Dimensions (W x H x D): 168 x 106 x 45 mm Protection class: II Plug-in power supply Primary voltage: AC 100 ... 240 V ~ Mains frequency: 50/60 Hz Secondary voltage: DC 12 V SELV Secondary current: 2 A Protection class: II Version: German Version: with Europlug Manufacturer: JUNG Ref.-no.: JVP-SERVER-H2

Technische Daten

ETIM-Klasse: Visualisierungs-Software (EC001416)

Communication

Mit OPC-Schnittstelle, Server
Ja
Mit OPC-Schnittstelle, Client
Ja
Mit Programmierschnittstellen
Nein

Options

Runtime-Betriebssystem, Windows 2000
Nein
Runtime-Betriebssystem, Windows XP
Nein
Runtime-Betriebssystem, LINUX
Nein
Runtime-Betriebssystem, sonstige
Ja
Ablauffähig für Projektierungsbetriebssystem, Windows 9x
-
Ablauffähig für Projektierungsbetriebssystem, Windows NT
-
Ablauffähig für Projektierungsbetriebssystem, Windows 2000
-
Ablauffähig für Projektierungsbetriebssystem, Windows ME
-
Ablauffähig für Projektierungsbetriebssystem, Windows XP
-
Ablauffähig für Projektierungsbetriebssystem, LINUX
-
Mehrplatzfähigkeit, Runtime
Nein
Max. Serveranzahl
1
Max. Clientanzahl
10
SCADA-Funktionalität
Nein
Alarm-Management
Nein
Trend-Darstellung
Ja
Max. Anzahl Multiuser Projektierung
-
Onlineprojektierung möglich
Nein
Integrierbar i.d. Engineeringsoftware f.d. Autom.-System
Ja
Sprachumschaltung möglich
Ja
Benutzergruppen (Passwortschutz) möglich
Ja

Application

Runtime-Betriebssystem, Windows Vista
Nein
Geeignet für Betriebssystem Windows 7
Ja
Geeignet für Betriebssystem Windows 8
Ja
Ablauffähig für Projektierungsbetriebssystem, Windows 2003 Server
-
Ablauffähig für Projektierungsbetriebssystem, Windows Vista
-
Ablauffähig für Projektierungsbetriebssystem, Windows 7
-
Ablauffähig für Projektierungsbetriebssystem, Windows 8
-
Geeignet für Web-Clients
Ja

Other

Min. Hauptspeicher, Runtimesystem
- Mbyte
Branchen- u. technologische Erweiterungen
integriert
Anzahl der Online/Runtime-Sprachen
2
Anzahl der Projektierungs/Runtime-Sprachen
2
Anzahl der Projektierungs-Oberflächensprachen
2
Objektbausteinbibliothek
integriert
Anwender-Archiv/Rezepturverwaltung
integriert
Reportsystem/Protokollsystem
integriert
Funktion Prozessdiagnose
-
SQL-Datenbank
nicht verfügbar
Min. Prozessortaktfrequenz, Runtimesystem
- GHz

Operating conditions

Min. Hauptspeicher, Projektierungssystem
- Mbyte
Min. Prozessortaktfrequenz, Projektierungssystem
1.466 GHz

Model/type

Mit Skriptsprache Visual Basic
Nein
Mit sonstiger Skriptsprache
Ja
Meldesystem
integriert

Logistik

Ursprungsland
Deutschland
Zolltarifnummer
85371098

Verpackung

VerpackungseinheitMengeGTINBruttogewichtAbmessungen (L × B × T)
Paket1—1,33 kg262 × 192 × 114 mm

Dokumente