Jung

Room thermostat universal with display, LS range, anthracite (lacquered)

Herstellernummer
EAN
Preis auf AnfrageFragen Sie ein Angebot für dieses Produkt an.

Bestellung

Bestelleinheit
Stück

Beschreibung

Automatic control with programmable time and temperature settings possible with white illuminated display screw fixing only, without claws Delivery capacity is ensured until the end of March 2021.   Intended use Measurement and feedback control of the room temperature Measuring and controlling the floor temperature Room temperature control via floor heating with a limiting function (for example in conjunction with tiled stoves) Can be used for "heating only" or "cooling only" Installation in flush box according to DIN 49073 Only for use in dry, enclosed rooms   Product characteristics Large display with backlighting Text display for self-explanatory operation Programmable even when the controls are removed Different user languages can be selected Real-time clock with automatic summer/winter time changeover Internal temperature sensor An external remote sensor can be connected Three selectable and adjustable time temperature programs for automatic mode A maximum of nine operating times per day (the setting can also be terminated after a specific operating time) Can be individually programmed every day, or a block of operating times can be set: workdays/non-workdays, all days the same Can be manually adjusted at any time "Vacation" mode with the entered date (from/to) "At-home" mode (present) Short-time timer ("party function") Frost protection function Display of energy consumption for electric heating systems Pulse width modulation (PWM) or two-point control system Adjustable cycle time (PWM), hysteresis and minimum on/off time (two-point) Switch-on delay, such as for burners (with two-point control) Adaptation to valves normally open or normally closed) Valve protection (as a room temperature controller with and without a limiting function) Separate resetting of user and installer settings Heating interruption acc. to EN 50559 adjustable (not for valves opened without power)   The control method depends on the type of heating and is determined by the installer: Room temperature controller: The heating is turned on when the room temperature falls below the set target temperature (measured with an internal sensor or external remote sensor). Floor temperature controller: The underfloor heating is turned on when the floor temperature falls below the set target temperature (measured using an external remote sensor). Room temperature controller with a limiter (in conjunction with underfloor heating): The room temperature is measured and regulated using the internal sensor. An additional external remote sensor is connected to measure the floor temperature, and a target temperature range for the floor is set. The room temperature control is deactivated when the floor temperature is outside of this range. If temperature falls below this range, the heater is turned on, and if the temperature is above this range, the heater is turned off independent of the current room temperature.

Ausschreibungstext

Room thermostat universal with display Room thermostat universal with display metal versions Delivery capacity is ensured until the end of March 2021. Intended use ■ Measurement and feedback control of the room temperature ■ Measuring and controlling the floor temperature ■ Room temperature control via floor heating with a limiting function (for example in conjunction with tiled stoves) ■ Can be used for "heating only" or "cooling only" ■ Installation in flush box according to DIN 49073 ■ Only for use in dry, enclosed rooms Product characteristics ■ Large display with backlighting ■ Text display for self-explanatory operation ■ Programmable even when the controls are removed ■ Different user languages can be selected ■ Real-time clock with automatic summer/winter time changeover ■ Internal temperature sensor ■ An external remote sensor can be connected ■ Three selectable and adjustable time temperature programs for automatic mode ■ A maximum of nine operating times per day (the setting can also be terminated after a specific operating time) ■ Can be individually programmed every day, or a block of operating times can be set: workdays/non-workdays, all days the same ■ Can be manually adjusted at any time ■ "Vacation" mode with the entered date (from/to) ■ "At-home" mode (present) ■ Short-time timer ("party function") ■ Frost protection function ■ Display of energy consumption for electric heating systems ■ Pulse width modulation (PWM) or two-point control system ■ Adjustable cycle time (PWM), hysteresis and minimum on/off time (two-point) ■ Switch-on delay, such as for burners (with two-point control) ■ Adaptation to valves normally open or normally closed) ■ Valve protection (as a room temperature controller with and without a limiting function) ■ Separate resetting of user and installer settings ■ Heating interruption acc. to EN 50559 adjustable (not for valves opened without power) The control method depends on the type of heating and is determined by the installer: Room temperature controller: The heating is turned on when the room temperature falls below the set target temperature (measured with an internal sensor or external remote sensor). Floor temperature controller: The underfloor heating is turned on when the floor temperature falls below the set target temperature (measured using an external remote sensor). Room temperature controller with a limiter (in conjunction with underfloor heating): The room temperature is measured and regulated using the internal sensor. An additional external remote sensor is connected to measure the floor temperature, and a target temperature range for the floor is set. The room temperature control is deactivated when the floor temperature is outside of this range. If temperature falls below this range, the heater is turned on, and if the temperature is above this range, the heater is turned off independent of the current room temperature. Technical data Rated voltage: AC 230 V ~, 50 Hz, neutral conductor required Output: relay (NO contact) Switching current as room temperature controller: 10 mA ... 10 (4) A, 230 V ~ as floor temperature controller: 10 mA ... 16 (4) A, 230 V ~ Power consumption: approx. 1.2 W Ambient temperature: 0 ... +40 °C (no condensation) Storing temperature: −20 ... +70 °C (no condensation) Temperature setting range: in increments of 0.5 °C as room temperature controller: 5 ... 30 °C as floor temperature controller: 10 ... 40 °C Temperature indication: in increments of 0.1 °C Output signal: pulse width modulation (PWM) or two-point control (on/off) PWM cycle time: adjustable (10 ... 30 min) Hysteresis: adjustable (with two-point control) Minimum switching time: adjustable (1 ... 30 min) Power reserve: approx. 10 years (lithium cell) Material: thermoplastic lacquered Colour: anthracite (lacquered) Manufacturer: JUNG Ref.-no.: TR UD AL 231 AN

Technische Daten

ETIM-Klasse: Raumthermostat (EC010927)

Model/type

Ausführung
markengebunden
Mit Empfänger
Nein
Sensor extern
Nein
Thermische Rückkopplung
-
Mit Geräuschniveauanzeige
Nein
Ausführung Aufnehmer/Fühler
Bimetall
Anzahl der Module (bei Modulbauweise)
-
Mit Display
Ja
Mit Trinkwasserschaltung
Nein

Electrical

Art der Spannungsversorgung
230 V AC
Max. Spannung der Kontakte
- V
Max. Kontaktbelastung
- A
Leistungsaufnahme im Bereitschaftszustand (solstandby)
- W

Connection

Anschluss
Zweidraht
Regelcharakteristik
-
Anzahl der Ausgänge Heizung
1
Anzahl der Ausgänge Kühlung
1
Messbereich unterer Wert
5.0
Messbereich oberer Wert
30.0
Heizen
true
Kühlen
true
Typ Kontakt
Schließer

Other

Differenzwert
0.5, 0.5 K

Setting/control

Differenz verstellbar
Nein
Bedienung
Taste
Klasse des Temperaturreglers
-

Options

Temperatur ablesbar
Ja

Mounting/installation

Montageart
Unterputz

Protection

Schutzart (IP)
IP31
Schutzart (NEMA)
-
Explosionsgeschützt
-

Colour

Farbe
anthrazit
RAL-Nummer
-

Measurements

Höhe
70 mm
Breite
70 mm
Tiefe
- mm
Durchmesser
- mm

Logistik

Ursprungsland
Deutschland
Zolltarifnummer
90321080

Verpackung

VerpackungseinheitMengeGTINBruttogewichtAbmessungen (L × B × T)
Paket1—0,206 kg82 × 82 × 90 mm
Karton10—2,223 kg420 × 170 × 98 mm