Skip to content
Eltracore

Photo 1 of 3

ABB

MS132-16T Circuit-breaker for primary

Manufacturer part no.
EAN
Series
MS132
Guest price€55.90 / pcexcl. VATMinimum order 1Delivery in about 10 business daysSign in to see your personal price

Ordering

Order unit
piece

Description

The circuit breaker for transformer protection MS132-16T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 16 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks and terminal spacers are available as accessory.

Tender text

Transformatorschutzschalter MS132-T mit thermischem und elektromagnetischem Schutz mit hohem Kurzschlussausschaltzvermögen für Transformatoren mit Primärstömen bis 25 A gemäß IEC/EN60947-1, -2, -4-1. UL-Zulassung als "Motor controller" für Sonderanwendung Transformatorschutz erlaubt den Einsatz in Nordamerika. Der primärseitige Transformatornennstrom wird durch Einstellen an der Stromskala thermisch überwacht. Die Kurzschlussauslösung erfolgt bei Auftreten des 20-fachen Gerätenennstroms. Das temperaturkompensierte Gerät besitzt eine Modulbreite von 45 mm, wird mithilfe eines direkt abschließbaren Drehgriffes mit einer klaren Schaltstellungsanzeige (I/TRIP/0) bedient und verfügt über eine Kurzschlussanzeige. Hilfs-, Signal- und Kurzschlussmeldekontakte sowie Unterspannungs- und Arbeitsstromauslöser können ohne Werkzeug angebaut werden. 1-Phaseneinspeiseblöcke bis 25 mm² und Phasenverbinder unterstützen die Verdrahtung von 1-Phasentransformatoren. Normen: IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, IEC 60335-2-40 A2L Anzahl Pole: 3P Bemessungsausschaltvermögen Im, Bemessungsfehlerschaltvermögen IΔm: 100 kA, 100 kA, 30 kA Bemessungsbetriebsspannung: 690 V AC Bemessungsdauerstrom: 16 A Bemessungsisolationsspannung: 690 V Bemessungsstoßspannungsfestigkeit: 6 kV

Technical data

ETIM class: Power circuit-breaker for trafo/generator/installation protection (EC000228)

Electrical

Rated permanent current Iu
16 A
Rated voltage
690, 690 V
Rated short-circuit breaking capacity Icu at 400 V, 50 Hz
100 kA
Overload release current setting
10, 16 A
Adjustment range short-term delayed short-circuit release
NA, - A
Adjustment range undelayed short-circuit release
320, 320 A
Power loss
6.9 W
With integrated under voltage release
-
Number of poles
3

Other

Device construction
Complete device in housing

Protection

Integrated earth fault protection
No
Complete device with protection unit
Yes
Degree of protection (IP)
IP20

Connection

Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Position of connection for main current circuit
Front side

Mounting/installation

Suitable for DIN rail (top hat rail) mounting
Yes
DIN rail (top hat rail) mounting optional
Yes

Model/type

With switched-off indicator
Yes
Type of control element
Turn button
Motor drive integrated
No

Options

Motor drive optional
No

Logistics

Net weight
0.31 kg
Country of origin
Germany
Customs tariff number
85362010

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
BE0———