The HF-ROL-range is used for forward and reverse running motors, as well as for switching non resistive loads. With contactor and overload relay functionalities integrated into one device, the results are faster wiring times and fewer faults. The range covers 0.6 A, 2.4 A and up to 9 A - for motors up to 3 kW – 500 V AC. The integrated electronic overload protection has a wide setting range that enables just three models to cover all requirements. Setting range of HF0.6-ROL-24VDC is 0.075 A to 0.6 A. The control supply voltage is 24 V DC. For the control and main connection points ABB offers screw connections. ABB also offers a HF-ROLE safety range with emergency stop function. This offers Safety Integrity Level 3, in accordance with functional safety standard IEC 61508-1 and Performance Level 'e' in accordance with ISO 13849-1. The safety range is ATEX-certified.
Tender text
Die elektronischen Kompaktstarter der Baureihe HF...ROL-24VDC sind Hybridstarter für Motoren bis 3 kW / 400 V bzw. ohmsche Lasten bis 9A / 400 V gemäß IEC/EN 60947-1, -4-2. Sie haben ein Baubreitenmaß von 22,5 mm und beinhalten die Funktionen Wendestart und Überlastschutz. Durch die Hybrid-Technik aus Halbleitern und Bypass-Kontakten eignen sich HF-Starter besonders für Anwendungen mit häufigen Schaltvorgängen und sind dabei verlustarm. Normen: IEC/EN 60947-1, IEC/EN 60947-4-2, UL 60947-1, UL 60947-4-2 Anzahl Pole: 3P Auslöseklasse: 10A Bemessungsbetriebsstrom AC-51: 0.6 A Bemessungsbetriebsstrom AC-53A: 0.6 A Bemessungssteuerspeisespannung: 24 V DC Betriebsspannung: 550 V AC, 42 V AC Einstellbereich: 0.075 ... 0.600 A Funktion: Umkehrstarter mit Überlastschutz Phasenausfallempfindlich: Ja Überlastschutz: Elektronischer Überlastschutz
Technical data
ETIM class: Motor starter/motor starter combination (EC001037)
Model/type
- Type of motor starter
- Reversing starter
- With short-circuit release
- No
- With transformer
- No
- Number of command positions
- 16
- Number of indicator lights
- 4
- With fuse
- No
Electrical
- Rated control supply voltage AC 50 Hz
- 0, 0 V
- Rated control supply voltage AC 60 Hz
- NA, - V
- Rated control supply voltage DC
- 24, 24 V
- Voltage type for actuating
- DC
- Rated operation power at AC-3, 230 V, 3-phase
- 0.09 kW
- Rated operation power at AC-3, 400 V
- 0.18 kW
- Rated power, 460 V, 60 Hz, 3-phase
- NA kW
- Rated power, 575 V, 60 Hz, 3-phase
- NA kW
- Rated operation current Ie
- 0.6 A
- Rated operation current at AC-3, 400 V
- 0.6 A
- Overload release current setting
- 0.075, 0.600 A
- Rated conditional short-circuit current, type 1, 480 Y/277 V
- NA A
- Rated conditional short-circuit current, type 1, 600 Y/347 V
- NA A
- Rated conditional short-circuit current, type 2, 230 V
- NA A
- Rated conditional short-circuit current, type 2, 400 V
- NA A
- Power consumption
- 1.5 W
Connection
- Number of auxiliary contacts as normally open contact
- 0
- Number of auxiliary contacts as normally closed contact
- 0
- Type of electrical connection of main circuit
- Screw connection
- Type of electrical connection for auxiliary- and control current circuit
- Plug-in connection
Operating conditions
- Ambient temperature, upper operating limit
- 80 °C
- Ambient temperature, upper operating limit
- 353.15 °F
Options
- Temperature compensated overload protection
- Yes
- External reset possible
- Yes
Other
- Release class
- CLASS 10 A
Mounting/installation
- Suitable for rail mounting
- Yes
Application
- Suitable for emergency stop
- No
Approval/certification
- Coordination class according to IEC 60947-4-3
- NA
Protection
- Degree of protection (IP)
- IP20
- Degree of protection (NEMA)
- 1
Communication
- Supporting protocol for TCP/IP
- No
- Supporting protocol for PROFIBUS
- No
- Supporting protocol for CAN
- No
- Supporting protocol for INTERBUS
- No
- Supporting protocol for ASI
- No
- Supporting protocol for Modbus
- No
- Supporting protocol for Data-Highway
- No
- Supporting protocol for DeviceNet
- No
- Supporting protocol for SUCONET
- No
- Supporting protocol for LON
- No
- Supporting protocol for PROFINET IO
- No
- Supporting protocol for PROFINET CBA
- No
- Supporting protocol for SERCOS
- No
- Supporting protocol for Foundation Fieldbus
- No
- Supporting protocol for EtherNet/IP
- No
- Supporting protocol for AS-Interface Safety at Work
- No
- Supporting protocol for DeviceNet Safety
- No
- Supporting protocol for INTERBUS-Safety
- No
- Supporting protocol for PROFIsafe
- No
- Supporting protocol for SafetyBUS p
- No
- Supporting protocol for other bus systems
- No
Measurements
- Width
- 22.5 mm
- Width
- 0.88650 inch
- Height
- 99 mm
- Height
- 3.9006 inch
- Depth
- 114.5 mm
- Depth
- 4.51130 inch
Logistics
- Net weight
- 0.217 kg
- Country of origin
- Germany
- Customs tariff number
- 85371098