Skip to content
Eltracore

Photo 1 of 2

ABB

NFZ44E-20 12-20VDC Contactor Relay

Manufacturer part no.
EAN
Series
NFZ44E
Guest price€62.42 / pcexcl. VATMinimum order 1Delivery in about 45 business daysSign in to see your personal price

Ordering

Order unit
piece

Description

NFZ contactor relays are used for switching auxiliary and control circuits. NFZ contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...250 V 50/60 Hz or 12...250 V DC. NF contactor relays can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change NFZ contactor relays allow direct control by PLC-output ≥ 24 V DC 500 mA and obtain a reduced holding coil consumption. NFZ contactor relays withstand short voltage dips and voltage sags (SEMI F47-0706 compliance) between 24...250 V 50/60 Hz NFZ contactor relays have built-in surge protection and do not require additional surge suppressors - Poles: 8-pole contactor relays with a non-removable front-mounted auxiliary contact block (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and including the "Mechanically Linked" symbol on the contactor relay side) - Control Circuit: DC operated for NF..Z-20 contactors. Only NF..Z-20 contactor relays need to respect the polarity on the coil terminals (A1+ and A2-). - Accessories: a wide range of Accessories is available.

Tender text

4- oder 8-polige Hilfsschütze der Baureihe NF erfüllen die Relaisfunktion gemäß IEC/EN 60947-4-1 bzw. IEC/EN 60947-5-1 und sind AC/DC-ansteuerbar. Sie schalten Steuerkreise oder Lastkreise bis 4 A (230V). Alle Hilfskontakte sind als Zwangsgeführte Kontakte nach IEC60947-5-1 Anhang L 2.1 ausgeführt. Löschglieder sind integriert. Normen: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60335-2-40 LZGH2 A2L, UL 508, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 14-13 Anschlussart: Schraubklemme Anzahl Hilfskontakte Öffner: 4 Anzahl Hilfskontakte Schließer: 4 Bemessungssteuerspannung: 12 ... 20 V Einbaulage: 1, 1 +/-30°, 2, 3, 4, 5 Konventioneller thermischer Dauerstrom in freier Luft: 16 A

Technical data

ETIM class: Auxiliary contactor, relay (EC000196)

Electrical

Rated control supply voltage AC 50 Hz
NA, - V
Rated control supply voltage AC 60 Hz
NA, - V
Rated control supply voltage DC
12, 20 V
Voltage type for actuating
DC
Rated operation current
3 A
Rated operation current Ie, 400 V
3 A
Operating voltage AC 50 Hz
690, 690 V
Operating voltage AC 60 Hz
690, 690 V
Operating voltage DC
6, 6 V
Voltage type (operating voltage)
NA
Rated switch current
4 A

Mounting/installation

Mounting method
DIN-rail/screw

Model/type

With LED indication
No

Application

Suitable for manual operation
No

Connection

Interface
No
Number of auxiliary contacts as normally closed contact
4
Number of auxiliary contacts as normally open contact
4
Number of auxiliary contacts as normally closed contact, delayed switching
0
Number of auxiliary contacts as normally open contact, leading
0
Number of auxiliary contacts as change-over contact
0
Connection type auxiliary circuit
Screw connection

Measurements

Width
45 mm
Width
1.77165 inch
Height
86 mm
Height
3.38582 inch
Depth
110.5 mm
Depth
4.350385 inch

Logistics

Net weight
0.36 kg
Country of origin
France
Customs tariff number
85364900

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
BE0———