AS09-30-01S-26 230V50/60HZ Contactor

Manufacturer part no.
EAN
Series
AS09
Guest price€22.08 / pcexcl. VATMinimum order 1Delivery in about 31 business days
Checking availability…
Sign in to see your personal price

Ordering

Order unit
piece

Description

AS09 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The AS..S contactors are the spring terminal version of the AS... range. The AS... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.

Tender text

Schütze AS/ASL 09 bis AS/ASL 16 von 4 bis 7,5 kW AC-3 (400 V) stehen für die sehr kompakte Baureihe mit AC- oder DC-Ansteuerung. Sie schalten Leistungskreise mit Motoren, leicht induktiven oder nicht-induktiven Lasten und verfügen über 3 Hauptschließerkontakte sowie 1 bzw. 5 Hilfskontakte. Anbaubare Zubehörteile sind seitlich einsteckbare Löschglieder sowie 1- polige, frontseitig aufsteckbare Hilfsschalter. Alle Hilfsöffnerkontakte sind als Mirrorkontakte nach IEC60947-5-1 Anhang L ausgeführt. Weiteres Zubehör wie Zeitglieder für An- und Abfallverzögerung, Verdrahtungshilfen sowie Verriegelungsglieder u.a. ergänzen das Sortiment. Normen: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 Anschlussart: Federzugklemme Anzahl Hauptkontakte Öffner: 0 Anzahl Hauptkontakte Schließer: 3 Anzahl Hilfskontakte Öffner: 1 Anzahl Hilfskontakte Schließer: 0 Typ Blockschütz: 3-poliges Schütz Bemessungsbetriebsleistung AC-3: 4 kW, 4 kW, 4 kW, 4 kW, 4 kW, 2.2 kW Bemessungsbetriebsspannung: 690 V, 690 V Bemessungsbetriebsstrom AC-1: 20 A, 15 A, 12 A Bemessungsbetriebsstrom AC-3: 9 A, 8 A, 8 A, 5 A, 9 A, 9 A Bemessungssteuerspannung: 230 V, 230 V

Technical data

ETIM class: Power contactor, AC switching (EC000066)

Electrical

Rated control supply voltage AC 50 Hz
230, 230 V
Rated control supply voltage AC 60 Hz
230, 230 V
Rated control supply voltage DC
NA, - V
Voltage type for actuating
AC
Operating voltage AC 50 Hz
690, 690 V
Operating voltage AC 60 Hz
690, 690 V
Rated operation current Ie at AC-1, 400 V
20 A
Rated operation current Ie at AC-3, 400 V
9 A
Rated operation power at AC-3, 400 V
4 kW
Rated operation current Ie at AC-4, 400 V
NA A
Rated operation power at AC-4, 400 V
NA kW
Rated operation power NEMA
- kW

Connection

Number of normally closed contacts as main contact
0
Number of normally open contacts as main contact
3
Type of electrical connection of main circuit
Spring clamp connection
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
1

Options

Suitable for distribution board
No

Measurements

Width
45 mm
Width
1.77165 inch
Height
68 mm
Height
2.67716 inch
Depth
72.5 mm
Depth
2.85433225 inch

Logistics

Net weight
0.22 kg
Country of origin
China
Customs tariff number
85364900

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)