Skip to content
Eltracore

ABB

ASL09-30-32-81 24VDC Contactor

Manufacturer part no.
EAN
Series
ASL09
Guest price€33.07 / pcexcl. VATMinimum order 1Delivery in about 31 business daysSign in to see your personal price

Ordering

Order unit
piece

Description

ASL09 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The AS... series 2-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 1st stack with 3 main poles and 1 N.O. built-in auxiliary contact, with a non-removable front-mounted 2 N.O. + 2 N.C. auxiliary contact block (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor side. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. ASL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.

Tender text

Schütze AS/ASL 09 bis AS/ASL 16 von 4 bis 7,5 kW AC-3 (400 V) stehen für die sehr kompakte Baureihe mit AC- oder DC-Ansteuerung. Sie schalten Leistungskreise mit Motoren, leicht induktiven oder nicht-induktiven Lasten und verfügen über 3 Hauptschließerkontakte sowie 1 bzw. 5 Hilfskontakte. Anbaubare Zubehörteile sind seitlich einsteckbare Löschglieder sowie 1- polige, frontseitig aufsteckbare Hilfsschalter. Alle Hilfsöffnerkontakte sind als Mirrorkontakte nach IEC60947-5-1 Anhang L ausgeführt. Weiteres Zubehör wie Zeitglieder für An- und Abfallverzögerung, Verdrahtungshilfen sowie Verriegelungsglieder u.a. ergänzen das Sortiment. Normen: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 Anschlussart: Schraubklemme Anzahl Hauptkontakte Öffner: 0 Anzahl Hauptkontakte Schließer: 3 Anzahl Hilfskontakte Öffner: 2 Anzahl Hilfskontakte Schließer: 3 Typ Blockschütz: 3-poliges Schütz Bemessungsbetriebsleistung AC-3: 4 kW, 4 kW, 4 kW, 4 kW, 4 kW, 2.2 kW Bemessungsbetriebsspannung: 690 V, 690 V Bemessungsbetriebsstrom AC-1: 22 A, 18 A, 15 A Bemessungsbetriebsstrom AC-3: 9 A, 8 A, 8 A, 5 A, 9 A, 9 A Bemessungsisolationsspannung: 690 V, 690 V, 600 V Bemessungssteuerspannung: 24 V Konventioneller thermischer Dauerstrom in freier Luft: 22 A, 10 A

Technical data

ETIM class: Power contactor, DC switching (EC002552)

Electrical

Rated control supply voltage AC 50 Hz
NA, - V
Rated control supply voltage AC 60 Hz
NA, - V
Rated control supply voltage DC
24, 24 V
Voltage type for actuating
DC
Operating voltage AC 50 Hz
690, 690
Operating voltage AC 60 Hz
690, 690
Operating voltage DC
690, 690 V
Rated operation current Ie at AC-1, 400 V
22
Rated operation current Ie at DC-3 / DC-5 at 440 V
NA A
Rated operation current Ie at AC-3, 400 V
9
Rated operation power at DC-3 / DC-5 at 440 V
NA kW
Rated operation power at AC-3, 400 V
4
Rated operation power NEMA
NA kW
Rated operation current Ie at AC-4, 400 V
UN
Rated operation power at AC-4, 400 V
UN

Connection

Number of normally closed contacts as main contact
0
Number of normally open contacts as main contact
3
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as normally open contact
3
Number of auxiliary contacts as normally closed contact
3

Options

Suitable for distribution board
No

Measurements

Width
45 mm
Width
1.77165 inch
Height
68 mm
Height
2.67716 inch
Depth
100.2 mm
Depth
3.944874 inch

Logistics

Net weight
0.32 kg
Country of origin
China
Customs tariff number
85364900

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
BE0———