ASL12-30-10-81 24VDC Contactor
- Manufacturer part no.
- EAN
- Series
- ASL12
Ordering
- Order unit
- piece
Description
ASL12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The ASL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. ASL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
Tender text
Schütze AS/ASL 09 bis AS/ASL 16 von 4 bis 7,5 kW AC-3 (400 V) stehen für die sehr kompakte Baureihe mit AC- oder DC-Ansteuerung. Sie schalten Leistungskreise mit Motoren, leicht induktiven oder nicht-induktiven Lasten und verfügen über 3 Hauptschließerkontakte sowie 1 bzw. 5 Hilfskontakte. Anbaubare Zubehörteile sind seitlich einsteckbare Löschglieder sowie 1- polige, frontseitig aufsteckbare Hilfsschalter. Alle Hilfsöffnerkontakte sind als Mirrorkontakte nach IEC60947-5-1 Anhang L ausgeführt. Weiteres Zubehör wie Zeitglieder für An- und Abfallverzögerung, Verdrahtungshilfen sowie Verriegelungsglieder u.a. ergänzen das Sortiment. Normen: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 Anschlussart: Schraubklemme Anzahl Hauptkontakte Öffner: 0 Anzahl Hauptkontakte Schließer: 3 Anzahl Hilfskontakte Öffner: 0 Anzahl Hilfskontakte Schließer: 1 Typ Blockschütz: 3-poliges Schütz Bemessungsbetriebsleistung AC-3: 5.5 kW, 5.5 kW, 5.5 kW, 5.5 kW, 5.5 kW, 3 kW Bemessungsbetriebsspannung: 690 V, 690 V Bemessungsbetriebsstrom AC-1: 24 A, 20 A, 16 A Bemessungsbetriebsstrom AC-3: 12 A, 11 A, 11 A, 7 A, 12 A, 12 A Bemessungsisolationsspannung: 690 V, 690 V, 600 V Bemessungssteuerspannung: 24 V Konventioneller thermischer Dauerstrom in freier Luft: 25 A, 10 A
Technical data
ETIM class: Power contactor, DC switching (EC002552)
Electrical
- Rated control supply voltage AC 50 Hz
- NA, - V
- Rated control supply voltage AC 60 Hz
- NA, - V
- Rated control supply voltage DC
- 24, 24 V
- Voltage type for actuating
- DC
- Operating voltage AC 50 Hz
- 690, 690
- Operating voltage AC 60 Hz
- 690, 690
- Operating voltage DC
- 690, 690 V
- Rated operation current Ie at AC-1, 400 V
- 24
- Rated operation current Ie at DC-3 / DC-5 at 440 V
- NA A
- Rated operation current Ie at AC-3, 400 V
- 12
- Rated operation power at DC-3 / DC-5 at 440 V
- NA kW
- Rated operation power at AC-3, 400 V
- 5.5
- Rated operation power NEMA
- NA kW
- Rated operation current Ie at AC-4, 400 V
- UN
- Rated operation power at AC-4, 400 V
- UN
Connection
- Number of normally closed contacts as main contact
- 0
- Number of normally open contacts as main contact
- 3
- Type of electrical connection of main circuit
- Screw connection
- Number of auxiliary contacts as normally open contact
- 1
- Number of auxiliary contacts as normally closed contact
- 1
Options
- Suitable for distribution board
- No
Measurements
- Width
- 45 mm
- Width
- 1.77165 inch
- Height
- 68 mm
- Height
- 2.67716 inch
- Depth
- 72.5 mm
- Depth
- 2.854325 inch
Logistics
- Net weight
- 0.28 kg
- Country of origin
- China
- Customs tariff number
- 85364900
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| BE | 0 | — | — | — |