ASL16-30-32S-81 24VDC Contactor
- Manufacturer part no.
- EAN
- Series
- ASL16
Ordering
- Order unit
- piece
Description
ASL16 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The ASL..S contactors are the spring terminal version of the ASL... range. The AS... series 2-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 1st stack with 3 main poles and 1 N.O. built-in auxiliary contact, with a non-removable front-mounted 2 N.O. + 2 N.C. auxiliary contact block (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor side. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. ASL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
Tender text
Schütze AS/ASL 09 bis AS/ASL 16 von 4 bis 7,5 kW AC-3 (400 V) stehen für die sehr kompakte Baureihe mit AC- oder DC-Ansteuerung. Sie schalten Leistungskreise mit Motoren, leicht induktiven oder nicht-induktiven Lasten und verfügen über 3 Hauptschließerkontakte sowie 1 bzw. 5 Hilfskontakte. Anbaubare Zubehörteile sind seitlich einsteckbare Löschglieder sowie 1- polige, frontseitig aufsteckbare Hilfsschalter. Alle Hilfsöffnerkontakte sind als Mirrorkontakte nach IEC60947-5-1 Anhang L ausgeführt. Weiteres Zubehör wie Zeitglieder für An- und Abfallverzögerung, Verdrahtungshilfen sowie Verriegelungsglieder u.a. ergänzen das Sortiment. Normen: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 Anschlussart: Federzugklemme Anzahl Hauptkontakte Öffner: 0 Anzahl Hauptkontakte Schließer: 3 Anzahl Hilfskontakte Öffner: 2 Anzahl Hilfskontakte Schließer: 3 Typ Blockschütz: 3-poliges Schütz Bemessungsbetriebsleistung AC-3: 7.5 kW, 7.5 kW, 7.5 kW, 7.5 kW, 7.5 kW, 4 kW Bemessungsbetriebsspannung: 690 V, 690 V Bemessungsbetriebsstrom AC-1: 22 A, 17 A, 14 A Bemessungsbetriebsstrom AC-3: 15.5 A, 13.6 A, 12.5 A, 9 A, 15.5 A, 15.7 A Bemessungsisolationsspannung: 690 V, 690 V, 600 V Bemessungssteuerspannung: 24 V Konventioneller thermischer Dauerstrom in freier Luft: 22 A, 10 A
Technical data
ETIM class: Power contactor, DC switching (EC002552)
Electrical
- Rated control supply voltage AC 50 Hz
- NA, - V
- Rated control supply voltage AC 60 Hz
- NA, - V
- Rated control supply voltage DC
- 24, 24 V
- Voltage type for actuating
- DC
- Operating voltage AC 50 Hz
- 690, 690
- Operating voltage AC 60 Hz
- 690, 690
- Operating voltage DC
- 690, 690 V
- Rated operation current Ie at AC-1, 400 V
- 22
- Rated operation current Ie at DC-3 / DC-5 at 440 V
- NA A
- Rated operation current Ie at AC-3, 400 V
- 15.5
- Rated operation power at DC-3 / DC-5 at 440 V
- NA kW
- Rated operation power at AC-3, 400 V
- 7.5
- Rated operation power NEMA
- NA kW
- Rated operation current Ie at AC-4, 400 V
- UN
- Rated operation power at AC-4, 400 V
- UN
Connection
- Number of normally closed contacts as main contact
- 0
- Number of normally open contacts as main contact
- 3
- Type of electrical connection of main circuit
- Spring clamp connection
- Number of auxiliary contacts as normally open contact
- 3
- Number of auxiliary contacts as normally closed contact
- 3
Options
- Suitable for distribution board
- No
Measurements
- Width
- 45 mm
- Width
- 1.77165 inch
- Height
- 68 mm
- Height
- 2.67716 inch
- Depth
- 110.7 mm
- Depth
- 4.358259 inch
Logistics
- Net weight
- 0.32 kg
- Country of origin
- China
- Customs tariff number
- 85364900
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| BE | 0 | — | — | — |