Skip to content
Eltracore

ABB

CSU-2LV Current sensing unit LV

Manufacturer part no.
EAN
Series
TVOC-2
Guest price€1,355.21 / pcexcl. VATMinimum order 1Delivery in about 10 business daysSign in to see your personal price

Ordering

Order unit
piece

Description

Current sensing unit CSU-2LV is an accessory to the Arc Guard System TVOC-2 when dual conditioning of light and current is needed to prevent nuisance tripping of the Arc Guard System. Designed to be used in low voltage applications. Connect 1-4 current sensors RC120... and RC200... to the CSU-2LV to measure L1-L3 and Neutral. Measures wide range of nominal current 0,25... 4 kA and over current 0,25... 12 kA. The unit sends a continuous light to the TVOC-2 while no over current or error occurs. Settings for over current level, warning current level, measured phases etc. are done in the touch screen or through Modbus RTU communication protocol. K1 signal relay is a change-over contact that can be used to signal over current to other system. Combine the CSU-2LV with accessories TVOC-2-OP... to daisy chain several current sensing units and to connect ot TVOC-2 main unit. Rated supply voltage 24... 240 V AC, 24... 250 V DC.

Tender text

Stromwächtereinheit CSU-2, 24-250V AC/DC für Niederspannung Anschlussart: Schraubklemme Breite (Netto-Abmessung): 155.5 mm Höhe (Netto-Abmessung): 141.1 mm Nettogewicht: 0.42 kg Tiefe (Netto-Abmessung): 63.8 mm Umgebungstemperatur: -25 ... +70 °C, -25 ... +85 °C

Technical data

ETIM class: Current monitoring relay (EC001440)

Mounting/installation

Complete with socket
UN
Suitable for DIN rail (top hat rail) mounting
true
Suitable for front mounting
true
Pluggable on auxiliary contact block
false

Connection

Type of electric connection
Other
Number of outputs, undelayed, normally closed contact
UN
Number of outputs, undelayed, normally open contact
UN
Number of outputs, undelayed, change-over contact
UN
Number of outputs, delayed, normally closed contact
UN
Number of outputs, delayed, normally open contact
UN
Number of outputs, delayed, change-over contact
UN
Number of contacts as normally closed contact
-
Outputs, reversible delayed/undelayed
UN
Number of contacts as normally open contact
-
Number of contacts as change-over contact
-

Model/type

With detachable clamps
No
Type of current
-
With semiconductor output
UN

Electrical

External power supply required
Yes
Voltage type (supply voltage)
NA
Supply voltage AC 50 Hz
-, - V
Supply voltage AC 60 Hz
-, - V
Supply voltage DC
-, - V
Voltage measuring range
-, - V
Current measuring range
-, - A
Response value amperage 1
NA, - A
Response value amperage 2
NA, - A
Single-phase under current possible
-
Three-phase under current possible
No
Single-phase overcurrent possible
-
Three-phase overcurrent possible
No
Rated control supply voltage AC 50 Hz
UN
Rated control supply voltage AC 60 Hz
UN
Rated control supply voltage DC
UN
Voltage type for actuating
AC/DC
Voltage type (operating voltage)
-
Operating voltage AC 50 Hz
-, - V
Operating voltage AC 60 Hz
-, - V
Operating voltage DC
-, - V
Rated switch current
- A
Nominal current
UN
Max. starting current
UN

Options

Function delay-on energization
false
Function delay on de-energization
false
Function floating contact on energization
false
Function floating contact on de-energization
false
Function star-delta
false
Function pulse shaping
false
Function flashing, starting with pause, fixed time
UN
Function flashing, starting with pulse, fixed time
UN
Clock function, starting with pause, variable
UN
Clock function, starting with pulse, variable
UN
Single-phase hysteresis possible
Yes
Three-phase hysteresis possible
No
Contains function DC-voltage under current
Yes
Contains function DC-voltage overcurrent
Yes
Function DC-current hysteresis
Yes
External current transformer
-

Other

Time range
UN

Setting/control

Remote operation possible
true
Suitable as remote control
false
Min. adjustable delay-on energization time
- s
Min. adjustable off-delay time
- s

Operating conditions

Max. permitted delay-on energization time
- s
Max. permitted off-delay time
- s

Material

Material of contact insert
UN
Material contact
UN
Material of contact surface
UN

Measurements

Width
- mm
Width
- inch
Height
- mm
Height
- inch
Depth
- mm
Depth
- inch

Protection

Degree of protection (IP)
UN

Approval/certification

Relay technology category according to IEC 61810-7
UN

Logistics

Net weight
0.42 kg
Country of origin
Poland
Customs tariff number
85389099

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
BE0———