CSU-2LV Current sensing unit LV
- Manufacturer part no.
- EAN
- Series
- TVOC-2
Ordering
- Order unit
- piece
Description
Current sensing unit CSU-2LV is an accessory to the Arc Guard System TVOC-2 when dual conditioning of light and current is needed to prevent nuisance tripping of the Arc Guard System. Designed to be used in low voltage applications. Connect 1-4 current sensors RC120... and RC200... to the CSU-2LV to measure L1-L3 and Neutral. Measures wide range of nominal current 0,25... 4 kA and over current 0,25... 12 kA. The unit sends a continuous light to the TVOC-2 while no over current or error occurs. Settings for over current level, warning current level, measured phases etc. are done in the touch screen or through Modbus RTU communication protocol. K1 signal relay is a change-over contact that can be used to signal over current to other system. Combine the CSU-2LV with accessories TVOC-2-OP... to daisy chain several current sensing units and to connect ot TVOC-2 main unit. Rated supply voltage 24... 240 V AC, 24... 250 V DC.
Tender text
Stromwächtereinheit CSU-2, 24-250V AC/DC für Niederspannung Anschlussart: Schraubklemme Breite (Netto-Abmessung): 155.5 mm Höhe (Netto-Abmessung): 141.1 mm Nettogewicht: 0.42 kg Tiefe (Netto-Abmessung): 63.8 mm Umgebungstemperatur: -25 ... +70 °C, -25 ... +85 °C
Technical data
ETIM class: Current monitoring relay (EC001440)
Mounting/installation
- Complete with socket
- UN
- Suitable for DIN rail (top hat rail) mounting
- true
- Suitable for front mounting
- true
- Pluggable on auxiliary contact block
- false
Connection
- Type of electric connection
- Other
- Number of outputs, undelayed, normally closed contact
- UN
- Number of outputs, undelayed, normally open contact
- UN
- Number of outputs, undelayed, change-over contact
- UN
- Number of outputs, delayed, normally closed contact
- UN
- Number of outputs, delayed, normally open contact
- UN
- Number of outputs, delayed, change-over contact
- UN
- Number of contacts as normally closed contact
- -
- Outputs, reversible delayed/undelayed
- UN
- Number of contacts as normally open contact
- -
- Number of contacts as change-over contact
- -
Model/type
- With detachable clamps
- No
- Type of current
- -
- With semiconductor output
- UN
Electrical
- External power supply required
- Yes
- Voltage type (supply voltage)
- NA
- Supply voltage AC 50 Hz
- -, - V
- Supply voltage AC 60 Hz
- -, - V
- Supply voltage DC
- -, - V
- Voltage measuring range
- -, - V
- Current measuring range
- -, - A
- Response value amperage 1
- NA, - A
- Response value amperage 2
- NA, - A
- Single-phase under current possible
- -
- Three-phase under current possible
- No
- Single-phase overcurrent possible
- -
- Three-phase overcurrent possible
- No
- Rated control supply voltage AC 50 Hz
- UN
- Rated control supply voltage AC 60 Hz
- UN
- Rated control supply voltage DC
- UN
- Voltage type for actuating
- AC/DC
- Voltage type (operating voltage)
- -
- Operating voltage AC 50 Hz
- -, - V
- Operating voltage AC 60 Hz
- -, - V
- Operating voltage DC
- -, - V
- Rated switch current
- - A
- Nominal current
- UN
- Max. starting current
- UN
Options
- Function delay-on energization
- false
- Function delay on de-energization
- false
- Function floating contact on energization
- false
- Function floating contact on de-energization
- false
- Function star-delta
- false
- Function pulse shaping
- false
- Function flashing, starting with pause, fixed time
- UN
- Function flashing, starting with pulse, fixed time
- UN
- Clock function, starting with pause, variable
- UN
- Clock function, starting with pulse, variable
- UN
- Single-phase hysteresis possible
- Yes
- Three-phase hysteresis possible
- No
- Contains function DC-voltage under current
- Yes
- Contains function DC-voltage overcurrent
- Yes
- Function DC-current hysteresis
- Yes
- External current transformer
- -
Other
- Time range
- UN
Setting/control
- Remote operation possible
- true
- Suitable as remote control
- false
- Min. adjustable delay-on energization time
- - s
- Min. adjustable off-delay time
- - s
Operating conditions
- Max. permitted delay-on energization time
- - s
- Max. permitted off-delay time
- - s
Material
- Material of contact insert
- UN
- Material contact
- UN
- Material of contact surface
- UN
Measurements
- Width
- - mm
- Width
- - inch
- Height
- - mm
- Height
- - inch
- Depth
- - mm
- Depth
- - inch
Protection
- Degree of protection (IP)
- UN
Approval/certification
- Relay technology category according to IEC 61810-7
- UN
Logistics
- Net weight
- 0.42 kg
- Country of origin
- Poland
- Customs tariff number
- 85389099
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| BE | 0 | — | — | — |