CSU-2MV Current sensing unit MV

Manufacturer part no.
EAN
Guest price€1,727.93 / pcexcl. VATMinimum order 1Delivery in about 24 business daysSign in to see your personal price

Ordering

Order unit
piece

Description

Current sensing unit CSU-2MV is an accessory to the Arc Guard System TVOC-2 when dual conditioning of light and current is needed to prevent nuisance tripping of the Arc Guard System. Designed to be used in medium voltage applications. Connect 1-4 current sensors KECA... and KEVCD... to the CSU-2MV to measure L1-L3 and Neutral. Measures wide range of nominal current 0,1... 4 kA and over current 0,1... 12 kA. The unit sends a continuous light to the TVOC-2 while no over current or error occurs. Settings for over current level, warning current level, measured phases etc. are done in the touch screen or through Modbus RTU communication protocol. K1 signal relay is a change-over contact that can be used to signal over current to other system. Combine the CSU-2MV with accessories TVOC-2-OP... to daisy chain several current sensing units and to connect ot TVOC-2 main unit. Rated supply voltage 24... 240 V AC, 24... 250 V DC.

Technical data

ETIM class: Current monitoring relay (EC001440)

Connection

Type of electric connection
Other
Number of contacts as normally closed contact
-
Number of contacts as normally open contact
-
Number of contacts as change-over contact
-

Model/type

With detachable clamps
No
Type of current
-

Electrical

External power supply required
Yes
Voltage type (supply voltage)
NA
Supply voltage AC 50 Hz
-, - V
Supply voltage AC 60 Hz
-, - V
Supply voltage DC
-, - V
Voltage measuring range
-, - V
Current measuring range
-, - A
Response value amperage 1
NA, - A
Response value amperage 2
NA, - A
Single-phase under current possible
-
Three-phase under current possible
No
Single-phase overcurrent possible
-
Three-phase overcurrent possible
No
Voltage type (operating voltage)
-
Operating voltage AC 50 Hz
-, - V
Operating voltage AC 60 Hz
-, - V
Operating voltage DC
-, - V
Rated switch current
- A

Options

Single-phase hysteresis possible
Yes
Three-phase hysteresis possible
No
Contains function DC-voltage under current
Yes
Contains function DC-voltage overcurrent
Yes
Function DC-current hysteresis
Yes
External current transformer
-

Setting/control

Min. adjustable delay-on energization time
- s
Min. adjustable off-delay time
- s

Operating conditions

Max. permitted delay-on energization time
- s
Max. permitted off-delay time
- s

Measurements

Width
- mm
Width
- inch
Height
- mm
Height
- inch
Depth
- mm
Depth
- inch

Logistics

Net weight
0.42 kg
Customs tariff number
85389099

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)