Description

The CM-PAS.31S relay is from the CM three-phase monitors range. This relay operates with a rated control supply voltage / three-phase measuring voltage of 160-300 V AC and has a 2 c/o output with contacts rated at 250 V / 4 A. The CM-PAS.31S monitors the phase parameters phase failure, phase sequence and phase unbalance. An ON-delay is adjustable over a range of instantaneous to 30 s (0, 0.1-30 s). A sealable transparent cover for protection against unauthorized changes is available as accessory. The device offers screw connection technology with double-chamber cage connection terminals.

Tender text

Mit den Dreiphasenüberwachungsrelais CM Reihe kann eine zuverlässige und kontinuierliche Überwachung eines Dreiphasennetzes, den störungsfreien und wirtschaftlichen Betrieb von Maschinen und Anlagen garantiert werden. Darum überwachen die Dreiphasenüberwachungsrelais der CM Reihe je nach Bedarf die Phasenspannungen, die Phasenfolge, die Phasenasymmetrie, das Vorhandensein aller Phasen sowie den Neutralleiter. Beschriftungsschilder, plombierbare Klarsichtabdeckungen und Adapter für Schraubmontage sind als Zubehör erhältlich. Normen: CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 60255-27, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508 Anschlussart: Schraubklemme Ausgang: 2 Wechsler Bemessungsbetriebsstrom AC-12: 4 A Bemessungsbetriebsstrom AC-15: 3 A Bemessungsbetriebsstrom DC-12: 4 A Bemessungsbetriebsstrom DC-13: 2 A Bemessungsisolationsspannung: 600 V, 300 V Bemessungssteuerspeisespannung: (L-L) 160 ... 300 V AC Funktion: Phasenfehlererkennung, Phasenfolgeüberwachung, Phasenschwankungserkennung Messbereich: (L-L) 160 ... 300 V AC Zeitbereich: 0 Sekunde(n)

Technical data

ETIM class: Phase monitoring relay (EC001441)

Connection

Type of electric connection
Screw connection
Number of contacts as normally closed contact
2
Number of contacts as normally open contact
2
Number of contacts as change-over contact
2

Model/type

With detachable clamps
No

Electrical

External power supply required
No
Voltage type (supply voltage)
AC
Supply voltage AC 50 Hz
NA, - V
Supply voltage AC 60 Hz
NA, - V
Supply voltage DC
NA, - V
Voltage measuring range
-, - V
Voltage type (operating voltage)
AC
Operating voltage AC 50 Hz
-, - V
Operating voltage AC 60 Hz
-, - V
Operating voltage DC
NA, - V
Rated switch current
4 A

Options

Phase sequence monitoring
Yes
Phase failure detection
Yes
Function under voltage detection
No
Function overvoltage detection
No
Phase imbalance monitoring
Yes

Setting/control

Min. adjustable delay-on energization time
NA s
Min. adjustable off-delay time
NA s

Operating conditions

Max. permitted delay-on energization time
NA s
Max. permitted off-delay time
NA s

Measurements

Width
22.5 mm
Width
0.885825 inch
Height
85.6 mm
Height
3.370072 inch
Depth
103.7 mm
Depth
4.082669 inch

Logistics

Net weight
0.133 kg
Country of origin
Germany
Customs tariff number
85364900