ABB

S802PV-SP80 High Performance MCB

Manufacturer part no.
EAN
Series
S800PV
Guest price€204.76 / pcexcl. VATMinimum order 1Delivery in about 45 business daysSign in to see your personal price

Ordering

Order unit
piece

Description

The S802PV-SP80 is a 2-pole High Performance Circuit breaker for photovoltaics (DC) with B-characteristic, with cage terminal and a rated current of 80 A. It is a current limiting device with a maximum breaking capacity of 5kA at 800V. It can be used for voltages up to 800V DC. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S802PV-SP80 complies with IEC/EN 60947-2 and allows the use for industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S802PV-SP80 more comfortable. Due to the fast arc extinction of S802PV-SP80 your application will be secured.

Tender text

Hochleistungssicherungsautomaten zum Strangschutz vor Überlast und Kurzschluss auf der Gleichstromseite in Photovoltaik-Anlagen bis 1.500 V DC. Erfüllt Anforderungen der IEC/EN 60947-2 und Anhang P. Leiterquerschnitte bis zu 70 mm² können direkt an das Gerät angeschlossen werden. Hilfs- und Signalschalter sind am Gerät ohne Zusatzverdrahtung anbaubar. Normen: IEC/EN 60947-2 Anzahl Pole: 2P Anzahl geschützter Pole: 2 Auslösecharakteristik: SP Bemessungs-Grenzkurzschlussausschaltvermögen: 5 kA Bemessungsbetriebsspannung: 800 V DC Bemessungsstrom: 80 A Zubehör anbaubar: Ja

Technical data

ETIM class: Miniature circuit breaker (MCB) (EC000042)

Measurements

Built-in depth
82.5 mm
Built-in depth
3.248025 inch
Width in number of modular spacings
3

Electrical

Release characteristic
Other
Rated current
80 A
Rated voltage
- V
Rated insulation voltage Ui
1500 V
Rated impulse withstand voltage Uimp
8 kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
NA kA
Voltage type
DC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
NA kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
NA kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
NA kA
Power loss
12.8 W
Current limiting class
3
Overvoltage category
3

Model/type

Number of poles (total)
2
Number of protected poles
2

Other

Frequency
0, 0 Hz
Pollution degree
2

Mounting/installation

Flush-mounted installation
No

Options

Concurrently switching neutral conductor
No
Additional equipment possible
Yes

Protection

Degree of protection (IP)
IP20
Explosion-proof
No

Operating conditions

Ambient temperature during operating
-40, 70 °C
Ambient temperature during operating
-40, 158 °F

Connection

Connectable conductor cross section multi-wired
0, 50 mm²
Connectable conductor cross section multi-wired
0, 0.0775 in²
Connectable conductor cross section solid-core
0, 70 mm²
Connectable conductor cross section solid-core
0, 0.1085 in²

Logistics

Net weight
490 kg
Country of origin
Switzerland
Customs tariff number
85362090

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
BE0———