Photo 1 of 4
S804PV-SP20 High Performance MCB
- Manufacturer part no.
- EAN
- Series
- S800PV
Ordering
- Order unit
- piece
Description
The S804PV-SP20 is a 4-pole High Performance Circuit breaker for photovoltaics (DC) with B-characteristic, with cage terminal and a rated current of 20 A. It is a current limiting device with a maximum breaking capacity of 5kA at 1500V. It can be used for voltages up to 1500V DC. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S804PV-SP20 complies with IEC/EN 60947-2 and allows the use for industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S804PV-SP20 more comfortable. Due to the fast arc extinction of S804PV-SP20 your application will be secured.
Tender text
Hochleistungssicherungsautomaten zum Strangschutz vor Überlast und Kurzschluss auf der Gleichstromseite in Photovoltaik-Anlagen bis 1.500 V DC. Erfüllt Anforderungen der IEC/EN 60947-2 und Anhang P. Leiterquerschnitte bis zu 70 mm² können direkt an das Gerät angeschlossen werden. Hilfs- und Signalschalter sind am Gerät ohne Zusatzverdrahtung anbaubar. Normen: IEC/EN 60947-2 Anzahl Pole: 4P Anzahl geschützter Pole: 4 Auslösecharakteristik: SP Bemessungs-Grenzkurzschlussausschaltvermögen: 5 kA Bemessungsbetriebsspannung: 1500 V DC Bemessungsstrom: 20 A Zubehör anbaubar: Ja
Technical data
ETIM class: Miniature circuit breaker (MCB) (EC000042)
Measurements
- Built-in depth
- 82.5 mm
- Built-in depth
- 3.248025 inch
- Width in number of modular spacings
- 6
Electrical
- Release characteristic
- Other
- Rated current
- 20 A
- Rated voltage
- - V
- Rated insulation voltage Ui
- 1500 V
- Rated impulse withstand voltage Uimp
- 8 kV
- Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
- NA kA
- Voltage type
- DC
- Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
- NA kA
- Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
- NA kA
- Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
- NA kA
- Power loss
- 14 W
- Current limiting class
- 3
- Overvoltage category
- 3
Model/type
- Number of poles (total)
- 4
- Number of protected poles
- 4
Other
- Frequency
- 0, 0 Hz
- Pollution degree
- 2
Mounting/installation
- Flush-mounted installation
- No
Options
- Concurrently switching neutral conductor
- No
- Additional equipment possible
- Yes
Protection
- Degree of protection (IP)
- IP20
- Explosion-proof
- No
Operating conditions
- Ambient temperature during operating
- -40, 70 °C
- Ambient temperature during operating
- -40, 158 °F
Connection
- Connectable conductor cross section multi-wired
- 0, 50 mm²
- Connectable conductor cross section multi-wired
- 0, 0.0775 in²
- Connectable conductor cross section solid-core
- 0, 70 mm²
- Connectable conductor cross section solid-core
- 0, 0.1085 in²
Logistics
- Net weight
- 980 kg
- Country of origin
- Switzerland
- Customs tariff number
- 85362010
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| BE | 0 | — | — | — |