Skip to content
Eltracore

Photo 1 of 4

ABB

The S803HV-C10 is a 3-pole High Performance Circuit breaker with C-characteristic, with cage terminal, long separating plates and a rated current of 10 A. It is a current limiting device with a maximum breaking capacity of 4kA at 580/1000V. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S803HV-C10 complies with IEC/EN 60947-2, UL1077 and allows the use for industrial applications. It can be used worldwide. The extensive range of accessory makes the use of S803HV-C10 more comfortable. Due to the fast arc extinction of S803HV-C10 your application will be secured.

Manufacturer part no.
EAN
Guest price€450.09 / pcexcl. VATMinimum order 1Delivery in about 45 business days
Checking availability…
Sign in to see your personal price

Ordering

Order unit
piece

Description

The S803HV-C10 is a 3-pole High Performance Circuit breaker with C-characteristic, with cage terminal, long separating plates and a rated current of 10 A. It is a current limiting device with a maximum breaking capacity of 4kA at 580/1000V. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S803HV-C10 complies with IEC/EN 60947-2, UL1077 and allows the use for industrial applications. It can be used worldwide. The extensive range of accessory makes the use of S803HV-C10 more comfortable. Due to the fast arc extinction of S803HV-C10 your application will be secured.

Technical data

ETIM class: Miniature circuit breaker (MCB) (EC000042)

Measurements

Built-in depth
82.5 mm
Built-in depth
3.248025 inch
Width in number of modular spacings
4.5

Electrical

Release characteristic
C
Rated current
10 A
Rated voltage
- V
Rated insulation voltage Ui
1000 V
Rated impulse withstand voltage Uimp
8 kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
NA kA
Voltage type
AC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
NA kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
NA kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
NA kA
Power loss
4.5 W
Current limiting class
NA
Overvoltage category
3

Model/type

Number of poles (total)
3
Number of protected poles
3

Other

Frequency
50, 60 Hz
Pollution degree
2

Mounting/installation

Flush-mounted installation
No

Options

Concurrently switching neutral conductor
No
Additional equipment possible
Yes

Protection

Degree of protection (IP)
IP20
Explosion-proof
No

Operating conditions

Ambient temperature during operating
-40, 70 °C
Ambient temperature during operating
-40, 158 °F

Connection

Connectable conductor cross section multi-wired
0, 50 mm²
Connectable conductor cross section multi-wired
0, 0.0775 in²
Connectable conductor cross section solid-core
0, 70 mm²
Connectable conductor cross section solid-core
0, 0.1085 in²

Logistics

Net weight
720 kg
Country of origin
Switzerland
Customs tariff number
85362010

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
BE0———