Skip to content
Eltracore

Photo 1 of 6

ABB

Fehlerstrom-Schutzschalter Typ B, 40A, 30mA, 4P, steckbar

Manufacturer part no.
EAN
Series
F400
Guest price€1,025.81 / pcexcl. VATMinimum order 1Delivery in about 45 business daysSign in to see your personal price

Ordering

Order unit
piece

Description

The RCCBs F404 series assures protection to people and installations against fault current to earth. A large offer for standard instantaneous is completed with some configurations for special applications. This product is particularly suitable for the protection against smooth d.c. earth fault currents. Type B residual current devices are marked according to EN 62423. The F404 B is for the SMISSLNE TP system. Rated current In 40A, Rated voltage Ue 230/400VAC, Rated sensitivity I Δn 0.03A

Tender text

Fehlerstrom-Schutzschalter (RCCBs) der Baureihe F400 Typ B für glatte Gleichfehlerströme und Betriebssicherheit, allstromsensitiv, 10 ms kurzzeitverzögert, stoßstromfest 3 kA. Fehlerstrom-Schutzeinrichtungen (RCCBs) bieten Personen- und Sachschutz sowie einen Schutz vor elektrisch gezündeten Bränden gemäß DIN VDE 0100-410 und DIN VDE 0100-530. Die Fehlerstrom-Schutzschalter der Baureihe F400 B gewährleisten Schutz bei sinusförmigen Wechselströmen, pulsierenden Strömen und glatten Gleichfehlerströmen gegen Erde. Sowie Fehlerschutz (Schutz bei indirektem Berühren), zusätzlichen Schutz (mit IΔn ≤ 30 mA) und Brandschutz (mit I∆n ≤ 300 mA). Sie erfüllen die Produktnormen für Typ A IEC/EN 61008-1, 61008-2-1, 61543 (VDE 0664 10, 11, 30) und Typ B DIN EN 62423 (VDE 0664-40). Einsatzgebiete sind vorwiegend in Gewerbe- und Industrieanwendungen. Anzahl Pole: 4P Bemessungsfrequenz: 50 ... 60 Hz Bemessungsstrom: 40 A Breite in Teilungseinheiten: 70 Fehlerstromart: Typ B Schutzart: IP20 Zubehör anbaubar: Ja

Technical data

ETIM class: Residual current circuit breaker (RCCB) (EC000003)

Electrical

Number of poles
4
Rated voltage
- V
Rated current
40 A
Rated fault current
30 A
Rated insulation voltage Ui
V
Rated impulse withstand voltage Uimp
4 kV
Power loss
9.6 W
Leakage current type
B
Short-circuit breaking capacity (Icw)
NA kA
Surge current capacity
3 kA
Voltage type
-

Mounting/installation

Mounting method
Other

Protection

Selective protection
No
Degree of protection (IP)
IP20
Explosion-proof
No

Model/type

Short-time delayed tripping
Yes
With interlocking device
Yes
Type of personal protection PRCD
-

Other

Frequency
Other
Pollution degree
2

Options

Additional equipment possible
Yes

Measurements

Width in number of modular spacings
4
Built-in depth
97 mm
Built-in depth
3.81889 inch
Device width
70 mm
Device width
2.75590 inch
Device height
67 mm
Device height
2.63779 inch
Device depth
97 mm
Device depth
3.81889 inch

Operating conditions

Ambient temperature during operating
-25, 55 °C
Ambient temperature during operating
-13, 131 °F

Connection

Connectable conductor cross section multi-wired
1, 25 mm²
Connectable conductor cross section multi-wired
0.0015, 0.0387 in²
Connectable conductor cross section solid-core
1, 25 mm²
Connectable conductor cross section solid-core
0.0015, 0.0387 in²

Colour

Colour
-
RAL-number (similar)
7035

Logistics

Net weight
435 kg
Country of origin
Switzerland
Customs tariff number
85362000

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
BE0———