Photo 1 of 6
Fehlerstrom-Schutzschalter Typ B, 40A, 30mA, 4P, steckbar
- Manufacturer part no.
- EAN
- Series
- F400
Ordering
- Order unit
- piece
Description
The RCCBs F404 series assures protection to people and installations against fault current to earth. A large offer for standard instantaneous is completed with some configurations for special applications. This product is particularly suitable for the protection against smooth d.c. earth fault currents. Type B residual current devices are marked according to EN 62423. The F404 B is for the SMISSLNE TP system. Rated current In 40A, Rated voltage Ue 230/400VAC, Rated sensitivity I Δn 0.03A
Tender text
Fehlerstrom-Schutzschalter (RCCBs) der Baureihe F400 Typ B für glatte Gleichfehlerströme und Betriebssicherheit, allstromsensitiv, 10 ms kurzzeitverzögert, stoßstromfest 3 kA. Fehlerstrom-Schutzeinrichtungen (RCCBs) bieten Personen- und Sachschutz sowie einen Schutz vor elektrisch gezündeten Bränden gemäß DIN VDE 0100-410 und DIN VDE 0100-530. Die Fehlerstrom-Schutzschalter der Baureihe F400 B gewährleisten Schutz bei sinusförmigen Wechselströmen, pulsierenden Strömen und glatten Gleichfehlerströmen gegen Erde. Sowie Fehlerschutz (Schutz bei indirektem Berühren), zusätzlichen Schutz (mit IΔn ≤ 30 mA) und Brandschutz (mit I∆n ≤ 300 mA). Sie erfüllen die Produktnormen für Typ A IEC/EN 61008-1, 61008-2-1, 61543 (VDE 0664 10, 11, 30) und Typ B DIN EN 62423 (VDE 0664-40). Einsatzgebiete sind vorwiegend in Gewerbe- und Industrieanwendungen. Anzahl Pole: 4P Bemessungsfrequenz: 50 ... 60 Hz Bemessungsstrom: 40 A Breite in Teilungseinheiten: 70 Fehlerstromart: Typ B Schutzart: IP20 Zubehör anbaubar: Ja
Technical data
ETIM class: Residual current circuit breaker (RCCB) (EC000003)
Electrical
- Number of poles
- 4
- Rated voltage
- - V
- Rated current
- 40 A
- Rated fault current
- 30 A
- Rated insulation voltage Ui
- V
- Rated impulse withstand voltage Uimp
- 4 kV
- Power loss
- 9.6 W
- Leakage current type
- B
- Short-circuit breaking capacity (Icw)
- NA kA
- Surge current capacity
- 3 kA
- Voltage type
- -
Mounting/installation
- Mounting method
- Other
Protection
- Selective protection
- No
- Degree of protection (IP)
- IP20
- Explosion-proof
- No
Model/type
- Short-time delayed tripping
- Yes
- With interlocking device
- Yes
- Type of personal protection PRCD
- -
Other
- Frequency
- Other
- Pollution degree
- 2
Options
- Additional equipment possible
- Yes
Measurements
- Width in number of modular spacings
- 4
- Built-in depth
- 97 mm
- Built-in depth
- 3.81889 inch
- Device width
- 70 mm
- Device width
- 2.75590 inch
- Device height
- 67 mm
- Device height
- 2.63779 inch
- Device depth
- 97 mm
- Device depth
- 3.81889 inch
Operating conditions
- Ambient temperature during operating
- -25, 55 °C
- Ambient temperature during operating
- -13, 131 °F
Connection
- Connectable conductor cross section multi-wired
- 1, 25 mm²
- Connectable conductor cross section multi-wired
- 0.0015, 0.0387 in²
- Connectable conductor cross section solid-core
- 1, 25 mm²
- Connectable conductor cross section solid-core
- 0.0015, 0.0387 in²
Colour
- Colour
- -
- RAL-number (similar)
- 7035
Logistics
- Net weight
- 435 kg
- Country of origin
- Switzerland
- Customs tariff number
- 85362000
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| BE | 0 | — | — | — |