Skip to content
Eltracore

Photo 1 of 4

ABB

S804U-PVS5 High Performance Circuit Breaker - S800U - Number of poles 4 - Tripping characteristic B - Rated current 5A

Manufacturer part no.
EAN
Series
S800U
Guest price€537.50 / pcexcl. VATMinimum order 1Delivery in about 45 business days
Checking availability…
Sign in to see your personal price

Ordering

Order unit
piece

Description

The S804U-PVS5 is a 4-pole High Performance Circuit Breaker with cage terminal and a rated current of 5A. This is device is developed to meet the requirements as GFDI (Ground Fault Detection Interrupteur) in photovoltaic systems. The rated voltage is 1000V DC. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S80U-PVS5 complies with UL489B and allows the use in photovoltaics in U.S.. The extensive range of accessory makes the use of S804U-PVS5 more comfortable. Due to the fast arc extinction of S804U-PVS5 your application will be secured.

Tender text

Hochleistungs-Sicherungsautomat zur Erdschlussüberwachung (GFDI) in Photovoltaikanlagen. Erfüllt Standard UL489B. Montage auf Hutschiene. Ausfallsichere Käfigklemme mit Anschluss bis Leiterquerschnitt von 1-70 mm2 bzw. AWG 14-2. Normen: UL 489B Anschlussart: Schraubklemme Anzahl Pole: 4P Anzahl geschützter Pole: 4 Auslösecharakteristik: B Bemessungsbetriebsspannung: 1000 V DC Bemessungsschaltvermögen: 2.5 kA, 2.5 kA Bemessungsstrom: 5 A Zubehör anbaubar: Ja Schaltstellungsanzeige: EIN / AUS / TRIP

Technical data

ETIM class: Miniature circuit breaker (MCB) (EC000042)

Measurements

Built-in depth
82.5 mm
Built-in depth
3.248025 inch
Width in number of modular spacings
6

Electrical

Release characteristic
B
Rated current
5 A
Rated voltage
- V
Rated insulation voltage Ui
1500 V
Rated impulse withstand voltage Uimp
8 kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
2.5 kA
Voltage type
DC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
- kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
- kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
- kA
Power loss
7.2 W
Current limiting class
3
Overvoltage category
4

Model/type

Number of poles (total)
4
Number of protected poles
4

Other

Frequency
0, 0 Hz
Pollution degree
3

Mounting/installation

Flush-mounted installation
No

Options

Concurrently switching neutral conductor
No
Additional equipment possible
Yes

Protection

Degree of protection (IP)
IP20
Explosion-proof
No

Operating conditions

Ambient temperature during operating
-25, 60 °C
Ambient temperature during operating
-13, 140 °F

Connection

Connectable conductor cross section multi-wired
0, 50 mm²
Connectable conductor cross section multi-wired
0, 0.0775 in²
Connectable conductor cross section solid-core
0, 70 mm²
Connectable conductor cross section solid-core
0, 0.1085 in²

Logistics

Net weight
980 kg
Country of origin
Switzerland
Customs tariff number
85362010

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
BE0———