Photo 1 of 4
S802S-K13 High Performance Circuit Breaker - S800S - Number of poles 2 - Tripping characteristic K - Rated current 13A - Cage terminal
- Manufacturer part no.
- EAN
- Series
- S800S
Ordering
- Order unit
- piece
Description
The S802S-K13 is a 2-pole High Performance Circuit breaker with K-Characteristic, with cage terminal and a rated current of 6 A. It is a current limiting device with a maximum breaking capacity of 50kA at 240/415V. It can be used for voltages up to 400/690V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S802S-K13 complies with IEC/EN 60898-1 and IEC/EN 60947-2 and allows the use for residential, commercial and industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S802S-K13 more comfortable. Due to the fast arc extinction of S802S-K13 your application will be secured.
Tender text
Hochleistungs-Sicherungsautomat zum Schutz vor Überlast und Kurzschluss von Kabel und Leitungen. Erfüllt Anforderungen der IEC 60947-2, EN 60898-1, UL 1077 sowie IEC 61373 und EN45545-2. Leiterquerschnitte bis zu 70 mm² können direkt an das Gerät angeschlossen werden. Sichere Potentialtrennung gemäß IEC 60947-2. Hilfs- und Signalschalter sind am Gerät ohne Zusatzverdrahtung anbaubar. Normen: IEC/EN 60947-2, IEC/EN 60898-1, UL 1077 Anschlussart: Schraubklemme Anzahl Pole: 2P Anzahl geschützter Pole: 2 Auslösecharakteristik: K Bemessungs-Grenzkurzschlussausschaltvermögen: 50 kA, 30 kA, 15 kA, 6 kA, 30 kA Bemessungsbetriebsspannung: 400 V AC, 690 V AC Bemessungsschaltvermögen: 25 kA Bemessungsstrom: 13 A Zubehör anbaubar: Ja Schaltstellungsanzeige: EIN / AUS / TRIP
Technical data
ETIM class: Miniature circuit breaker (MCB) (EC000042)
Measurements
- Built-in depth
- 82.5 mm
- Built-in depth
- 3.248025 inch
- Width in number of modular spacings
- 3
Electrical
- Release characteristic
- K
- Rated current
- 13 A
- Rated voltage
- V
- Rated insulation voltage Ui
- 690 V
- Rated impulse withstand voltage Uimp
- 8 kV
- Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
- NA kA
- Voltage type
- AC/DC
- Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
- NA kA
- Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
- - kA
- Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
- - kA
- Power loss
- 6.2 W
- Current limiting class
- 3
- Overvoltage category
- 4
Model/type
- Number of poles (total)
- 2
- Number of protected poles
- 2
Other
- Frequency
- 50, 60 Hz
- Pollution degree
- 3
Mounting/installation
- Flush-mounted installation
- No
Options
- Concurrently switching neutral conductor
- No
- Additional equipment possible
- Yes
Protection
- Degree of protection (IP)
- IP20
- Explosion-proof
- No
Operating conditions
- Ambient temperature during operating
- -40, 70 °C
- Ambient temperature during operating
- -40, 158 °F
Connection
- Connectable conductor cross section multi-wired
- 0, 50 mm²
- Connectable conductor cross section multi-wired
- 0, 0.0775 in²
- Connectable conductor cross section solid-core
- 0, 70 mm²
- Connectable conductor cross section solid-core
- 0, 0.1085 in²
Logistics
- Net weight
- 490 kg
- Country of origin
- Switzerland
- Customs tariff number
- 85362010
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| BE | 0 | — | — | — |