Skip to content
Eltracore

Photo 1 of 4

ABB

High Performance Circuit Breaker - S800U - Tripping characteristic K - Number of poles 2 - Rated operational current 90A - Rated operational voltage 240V AC

Manufacturer part no.
EAN
Series
S800U
Guest price€196.82 / pcexcl. VATMinimum order 1Delivery in about 45 business daysSign in to see your personal price

Ordering

Order unit
piece

Description

S802U-K90 2 Pole K Characteristic 90A 50kA 240/415VAC High Performance Circuit Breaker HPCB

Tender text

Hochleistungs-Sicherungsautomat zum Schutz vor Überlast und Kurzschluss von Kabel und Leitungen. Erfüllt Anforderungen der UL489 und IEC 60947-2 Leiterquerschnitte bis zu 70 mm² können direkt an das Gerät angeschlossen werden. Sichere Potentialtrennung gemäß IEC 60947-2. Hilfs- und Signalschalter sind am Gerät ohne Zusatzverdrahtung anbaubar. Normen: UL 489 Anzahl Pole: 2P Anzahl geschützter Pole: 2 Auslösecharakteristik: K Bemessungs-Grenzkurzschlussausschaltvermögen: 50 kA Bemessungsbetriebsspannung: 415 V AC, 240 V AC Bemessungsstrom: 90 A Zubehör anbaubar: Ja Schaltstellungsanzeige: EIN / AUS / TRIP

Technical data

ETIM class: Miniature circuit breaker (MCB) (EC000042)

Measurements

Built-in depth
82.5 mm
Built-in depth
3.248025 inch
Width in number of modular spacings
3

Electrical

Release characteristic
K
Rated current
90 A
Rated voltage
- V
Rated insulation voltage Ui
690 V
Rated impulse withstand voltage Uimp
8 kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
- kA
Voltage type
AC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
- kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
- kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
- kA
Power loss
6.5 W
Current limiting class
3
Overvoltage category
3

Model/type

Number of poles (total)
2
Number of protected poles
2

Other

Frequency
50, 60 Hz
Pollution degree
2

Mounting/installation

Flush-mounted installation
No

Options

Concurrently switching neutral conductor
No
Additional equipment possible
Yes

Protection

Degree of protection (IP)
IP20
Explosion-proof
No

Operating conditions

Ambient temperature during operating
-25, 60 °C
Ambient temperature during operating
-13, 140 °F

Connection

Connectable conductor cross section multi-wired
0, 50 mm²
Connectable conductor cross section multi-wired
0, 0.0775 in²
Connectable conductor cross section solid-core
0, 70 mm²
Connectable conductor cross section solid-core
0, 0.1085 in²

Logistics

Net weight
490 kg
Country of origin
Switzerland
Customs tariff number
85362010

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
BE0———