Skip to content
Eltracore

Photo 1 of 2

ABB

FI-Schalter 4P, Type F, 63A, 30mA

Manufacturer part no.
EAN
Series
F200
Guest price€160.37 / pcexcl. VATMinimum order 1Delivery in about 45 business daysSign in to see your personal price

Ordering

Order unit
piece

Description

The RCCBs F200 series assures protection to people and installations against fault current to earth. Type F offers the same range of protection and functionality as an RCCB Type A APR, this means that they detect sinusoidal AC currents as well as pulsating DC currents.

Tender text

Fehlerstrom-Schutzschalter (RCCBs) bieten Personen- und Sachschutz sowie einen Schutz vor elektrisch gezündeten Bränden gemäß DIN VDE 0100-410 und DIN VDE 0100-530. Die Fehlerstrom-Schutzschalter der Baureihe F200 Typ F gewährleisten Schutz bei sinusförmigen Wechselströmen und pulsierenden Strömen gegen Erde; sowie mischfrequenz Strömen mit einen Frequenzbereich von 0-1 kHz und zusätzlich pulsierende Fehlerströme mit einem DC-Anteil bis zu 10 mA. Sie erfüllen die Produktnormen für RCDs Typ A IEC/EN 61008-1, 61008-2-1, 61543 (VDE 0664 10, 11, 30) und für Typ F DIN EN 62423 (VDE 0664-40). Anschlussöffnung für Leitungen liegt oberhalb von der Anschlussöffnung für die Phasenschiene. Zubehör wie Hilfs- und Signalschalter sind am Gerät ohne Zusatzverdrahtung anbaubar. Normen: IEC/EN 61008-1, IEC/EN 61008-2-1, IEC/EN 62423 Anzahl Pole: 4P Bemessungsfehlerstrom: 30 mA Bemessungsfrequenz: 50 … 60 Hz Bemessungsspannung: 230/400 V Bemessungsstrom: 63 A Zeitverzögerung FI: 10 ms Verzögerung (hohe Immunität) Breite in Teilungseinheiten: 4 Fehlerstromart: Typ F Position des N-Leiters: Rechts Schutzart: IP20, IP40 Zubehör anbaubar: Ja

Technical data

ETIM class: Residual current circuit breaker (RCCB) (EC000003)

Electrical

Number of poles
4
Rated voltage
- V
Rated current
63 A
Rated fault current
NA A
Rated insulation voltage Ui
- V
Rated impulse withstand voltage Uimp
4 kV
Power loss
- W
Leakage current type
F
Short-circuit breaking capacity (Icw)
NA kA
Surge current capacity
4 kA
Voltage type
-

Mounting/installation

Mounting method
DIN rail

Protection

Selective protection
No
Degree of protection (IP)
IP20
Explosion-proof
No

Model/type

Short-time delayed tripping
Yes
With interlocking device
Yes
Type of personal protection PRCD
-

Other

Frequency
Other
Pollution degree
2

Options

Additional equipment possible
Yes

Measurements

Width in number of modular spacings
4
Built-in depth
69 mm
Built-in depth
2.71653 inch
Device width
70 mm
Device width
2.75590 inch
Device height
85 mm
Device height
3.34645 inch
Device depth
69 mm
Device depth
2.71653 inch

Operating conditions

Ambient temperature during operating
-25, 55 °C
Ambient temperature during operating
-13, 131 °F

Connection

Connectable conductor cross section multi-wired
0, 25 mm²
Connectable conductor cross section multi-wired
0, 0.0387 in²
Connectable conductor cross section solid-core
25, 25 mm²
Connectable conductor cross section solid-core
0.0387, 0.0387 in²

Colour

Colour
-
RAL-number (similar)
7035

Logistics

Net weight
375 kg
Country of origin
Italy
Customs tariff number
85363030

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
BE0———