Skip to content
Eltracore

Photo 1 of 4

ABB

FI/LS-Schalter 10 kA, 2P, Typ A, B10, 30 mA 2 Teilungseinheiten

Manufacturer part no.
EAN
Series
DS202CR M
Guest price€136.70 / pcexcl. VATMinimum order 48, in steps of 48Delivery in about 10 business days
Checking availability…
Sign in to see your personal price

Ordering

Order unit
piece
Minimum order
48
Order in steps of
48

Description

The DS202CR series RCBO is a 2P in two-modules device for the protection of end user single-phase circuits against overload and short-circuit currents. Protection against the effects of sinusoidal alternating and direct pulsating earth fault currents. Protection against indirect contacts and additional protection against direct contacts.

Tender text

FI/LS-Schalter (RCBOs) gemäß DIN VDE 0100-410 und DIN VDE 0100-530. Sie erfüllen die Produktnormen VDE 0664-20, VDE 0664-21. Für Netze mit 2 Phasen 230 V AC (ohne N-Leiter) oder mobile Verteiler über Schukostecker (1P+N) ver-sorgt, wie z.B.: Caravan-Anwendungen. Normen: IEC/EN 61009-1, IEC/EN 61009-2-1 Anzahl Pole: 2P Anzahl geschützter Pole: 2 Auslösecharakteristik: B Bemessungsfehlerstrom: 30 mA Bemessungsfrequenz: 50 Hz Bemessungsschaltvermögen: 10 kA Bemessungsstrom: 10 A Zeitverzögerung FI: unverzögert Breite in Teilungseinheiten: 2 Fehlerstromart: Typ A Position des N-Leiters: Rechts, Links Schutzart: IP20 Zubehör anbaubar: Ja Fehleranzeige: blaue Markierung über dem Schalthebel Anschlussmöglichkeit: 10…10 mm², 1...25 mm², 1…35 mm²

Technical data

ETIM class: Earth leakage circuit breaker (EC000905)

Model/type

Number of poles (total)
2
Number of protected poles
2
With interlocking device
No

Electrical

Rated voltage
V
Rated insulation voltage Ui
V
Rated impulse withstand voltage Uimp
4 kV
Rated current
10 A
Rated fault current
0.03 A
Leakage current type
A
Current limiting class
3
Power loss
3.28 W
Rated short-circuit breaking capacity according to EN 61009
10 kA
Rated short-circuit breaking capacity according to IEC 60947-2
10 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1
10 kA
Surge current capacity
0.25 kA
Voltage type
AC
Release characteristic
B
Overvoltage category
3

Mounting/installation

Mounting method
DIN rail
Flush-mounted installation
false

Connection

Disconnection characteristic
Undelayed
Connectable conductor cross section solid-core
-, - mm²
Connectable conductor cross section solid-core
-, - in²
Connectable conductor cross section multi-wired
1, 25 mm²
Connectable conductor cross section multi-wired
0.0015, 0.0387 in²

Other

Frequency
50 Hz
Pollution degree
3

Options

Concurrently switching neutral conductor
Yes
Anti-nuisance tripping version
No

Operating conditions

Ambient temperature during operating
-25, 55 °C
Ambient temperature during operating
-13, 131 °F

Measurements

Width in number of modular spacings
2
Built-in depth
72 mm
Built-in depth
2.83464 inch

Protection

Degree of protection (IP)
IP20

Logistics

Net weight
0.22 kg
Country of origin
Italy
Customs tariff number
85363010

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
BE0———