Skip to content
Eltracore

Photo 1 of 4

ABB

FI/LS-Schalter 10 kA, 2P, Typ A, C25, 30 mA AP-R kurzzeitverzögert 2 TE

Manufacturer part no.
EAN
Series
DS202CR M
Guest price€172.31 / pcexcl. VATMinimum order 1Delivery in about 59 business days
Checking availability…
Sign in to see your personal price

Ordering

Order unit
piece

Description

The DS202CR series RCBO is a 2P in two-modules device for the protection of end user single-phase circuits against overload and short-circuit currents. Protection against the effects of sinusoidal alternating and direct pulsating earth fault currents. Protection against indirect contacts and additional protection against direct contacts.

Tender text

FI/LS-Schalter (RCBOs) gemäß DIN VDE 0100-410 und DIN VDE 0100-530. Sie erfüllen die Produktnormen VDE 0664-20, VDE 0664-21. Für Netze mit 2 Phasen 230 V AC (ohne N-Leiter) oder mobile Verteiler über Schukostecker (1P+N) ver-sorgt, wie z.B.: Caravan-Anwendungen. Normen: IEC/EN 61009-1, IEC/EN 61009-2-1 Anzahl Pole: 2P Anzahl geschützter Pole: 2 Auslösecharakteristik: C Bemessungsfehlerstrom: 30 mA Bemessungsfrequenz: 50 Hz Bemessungsschaltvermögen: 10 kA Bemessungsstrom: 25 A Zeitverzögerung FI: 10 ms Verzögerung (hohe Immunität) Breite in Teilungseinheiten: 2 Fehlerstromart: Typ A APR Position des N-Leiters: Rechts, Links Schutzart: IP20 Zubehör anbaubar: Ja Fehleranzeige: blaue Markierung über dem Schalthebel Anschlussmöglichkeit: 10…10 mm², 1...25 mm², 1…35 mm²

Technical data

ETIM class: Earth leakage circuit breaker (EC000905)

Model/type

Number of poles (total)
2
Number of protected poles
2
With interlocking device
No

Electrical

Rated voltage
V
Rated insulation voltage Ui
V
Rated impulse withstand voltage Uimp
4 kV
Rated current
25 A
Rated fault current
0.03 A
Leakage current type
Other
Current limiting class
3
Power loss
6.20 W
Rated short-circuit breaking capacity according to EN 61009
10 kA
Rated short-circuit breaking capacity according to IEC 60947-2
10 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1
10 kA
Surge current capacity
3 kA
Voltage type
AC
Release characteristic
C
Overvoltage category
3

Mounting/installation

Mounting method
DIN rail
Flush-mounted installation
false

Connection

Disconnection characteristic
Other
Connectable conductor cross section solid-core
-, - mm²
Connectable conductor cross section solid-core
-, - in²
Connectable conductor cross section multi-wired
1, 25 mm²
Connectable conductor cross section multi-wired
0.0015, 0.0387 in²

Other

Frequency
50 Hz
Pollution degree
3

Options

Concurrently switching neutral conductor
Yes
Anti-nuisance tripping version
Yes

Operating conditions

Ambient temperature during operating
-25, 55 °C
Ambient temperature during operating
-13, 131 °F

Measurements

Width in number of modular spacings
2
Built-in depth
72 mm
Built-in depth
2.83464 inch

Protection

Degree of protection (IP)
IP20

Logistics

Net weight
0.22 kg
Country of origin
Italy
Customs tariff number
85363030

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)