Photo 1 of 3
OVR T2 3N 80-275s P QS
- Manufacturer part no.
- EAN
- Series
- T2
Ordering
- Order unit
- piece
Description
Surge protective devices SPD type 2 protect low-voltage consumer systems against surge voltages as they are tested as SPD type 2 according to IEC 61643-11. The devices are compatible with the System pro M compact series. The SPD with "TS" are optionally equipped with a auxiliary contact. The variants with "reserve varistor" (s) offer additional protection for the system, as the SPD is not completely disconnected from the mains at the end of its service life, but with an additional smaller varistor still guarantees basic protection and the system thus until the surge arrester is replaced is still protected
Tender text
OVR Typ 2 (SPD) Überspannungsschutz Ableiter mit Reserve-Varistor und QuickSafe® Technologie erfüllen die Produktnorm DIN EN 61643-11. Die Schutzgeräte können für den Einsatz als Überspannungs-Schutzeinrichtung nach VDE 0100 Teil 443 und Teil 534, sowie im Rahmen der Blitzschutznorm VDE 0185-305 verwendet werden. Normen: IEC 61643-11 / EN 61643-11 Anzahl Pole: 4P Anzahl geschützter Pole: 4 Art des Niederspannungsverteilsystems: (TT), TN-S Breite in Teilungseinheiten: 4 Entladestrom: 20 kA, 80 kA Kurzschlussfestigkeit Icc: 100 kA Schutzpegel: 1.4 kV, 1.4 kV, 1.4 kV Stoßstrom: 6.25 kA Überspannungsableiterklasse: II
Technical data
ETIM class: Surge protection device for power supply systems (EC000941)
Options
- System configuration DC
- No
- System configuration IT
- No
- System configuration TN
- Yes
- System configuration TN-C
- No
- System configuration TN-C-S
- Yes
- System configuration TN-S
- Yes
- System configuration TT
- Yes
- System configuration other
- No
- Leakage-current free
- Yes
Electrical
- Number of conductors (without earthing)
- 4
- Nominal discharge surge current (8/20)
- 20 kA
- Max. discharge surge current (8/20)
- 20 kA
- Nominal voltage AC
- 230 V
- Nominal voltage DC
- NA V
- Max. continuous voltage AC
- 275 V
- Max. continuous voltage DC
- NA V
- Max. PV-voltage
- NA V
- Voltage protection level
- 1.4 kV
- Voltage protection level L-N
- 1.4 kV
- Voltage protection level N-PE
- 1.4 kV
- Max. overcurrent protection device, parallel connection (fuse)
- 160 A
- Max. overcurrent protection device, series connection (fuse)
- 160 A
- Short-circuit breaking capacity (Isccr)
- 100 kA
- Integrated short-circuit protection selective to fuse gG
- NA A
Protection
- Integrated short-circuit protection
- No
- Degree of protection (IP)
- IP20
Model/type
- Integrated backup fuse
- No
- Category type 2
- Yes
Mounting/installation
- Mounting method
- Other
Measurements
- Construction size
- 4 modular spacing
Connection
- Max. conductor cross section solid (solid, stranded)
- 35 mm²
- Max. conductor cross section solid (solid, stranded)
- 0.054250108500217000434000868 in²
- Max. conductor cross section flexible (fine-strand)
- 25 mm²
- Max. conductor cross section flexible (fine-strand)
- 0.03875007750015500031000062 in²
Communication
- With remote signalling contact
- Yes
Other
- Signalling at the device
- Optical
Logistics
- Net weight
- 0.6 kg
- Country of origin
- Bulgaria
- Customs tariff number
- 85363090
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| BE | 0 | — | — | — |