Photo 1 of 3
B752511
- Manufacturer part no.
- EAN
- Series
- T1-T2
Ordering
- Order unit
- piece
Description
Surge protective devices SPD type 1- type 2 protect low-voltage consumer systems against lightning currents and surge voltages as they are tested as SPD type 1 and type 2 according to IEC 61643-11. The devices are compatible with the System pro M compact series. The SPD with "TS" are optionally equipped with a auxiliary contact. The variants with "reserve varistor" (s) offer additional protection for the system, as the SPD is not completely disconnected from the mains at the end of its service life, but with an additional smaller varistor still guarantees basic protection and the system thus until the surge arrester is replaced is still protected
Tender text
OVR Typ 1+2 (SPD) Blitz- und Überspannungsschutz Ableiter mit Reserve-Varistor und QuickSafe® Technologie erfüllen die Produktnorm DIN EN 61643-11. Die Schutzgeräte können für den Einsatz als Überspannungs-Schutzeinrichtung nach VDE 0100 Teil 443 und Teil 534, sowie im Rahmen der Blitzschutznorm VDE 0185-305 verwendet werden. Normen: IEC 61643-11 / EN 61643-11 Überspannungsableiterklasse: I, II Produkttyp: QS Anzahl Pole: 4P Art des Niederspannungsverteilsystems: TN-S, (IT) Folgestromlöschvermögen: - kA, - kA Entladestrom: 20 kA, 80 kA, 320 kA Stoßstrom: 12.5 kA, 50 kA Kurzschlussfestigkeit Icc: 100 kA Kurzschlussschutzeinrichtung: ≤ 125 A, ≤ 125 A, ≤ 160 A, ≤ 160 A Schutzpegel: 3.8 kV, 1.9 kV, 1.9 kV Breite in Teilungseinheiten: 8
Technical data
ETIM class: Combined arrester for power supply systems (EC001457)
Options
- System configuration DC
- Yes
- System configuration IT
- No
- System configuration TN
- No
- System configuration TN-C
- No
- System configuration TN-C-S
- No
- System configuration TN-S
- Yes
- System configuration TT
- No
- System configuration other
- No
- Remote signalling
- Yes
Electrical
- Number of poles
- 4
- Lightning impulse current (10/350 µs)
- 12.5 kA
- Max. continuous voltage AC
- - V
- Max. continuous voltage DC
- - V
- Nominal voltage AC
- - V
- Nominal voltage DC
- - V
- Max. PV-voltage
- NA V
- Voltage protection level
- - kV
- Voltage protection level L-N
- 3.8 kV
- Voltage protection level L-PE
- 1.9 kV
- Voltage protection level N-PE
- 1.9 kV
- Voltage protection level (DC+ - DC-)
- NA kV
- Voltage protection level (DC+/DC- - PE)
- NA kV
- Follow current extinguishing capability
- - kA
- Max. overcurrent protection device, parallel connection (fuse)
- - A
- Max. overcurrent protection device, series connection (fuse)
- - A
- Voltage switching spark gap technology
- No
- Overcurrent protected voltage tapping
- No
Other
- Specific energy (W/R)
- NA kJ/Ohm
- Signalling at the device
- -
- Test class
- -
Mounting/installation
- Mounting method
- -
Measurements
- Construction size
- 8 modular spacing
Connection
- Max. conductor cross section solid (solid, stranded)
- NA mm²
- Max. conductor cross section solid (solid, stranded)
- NA in²
- Max. conductor cross section flexible (fine-strand)
- - mm²
- Max. conductor cross section flexible (fine-strand)
- - in²
Model/type
- Integrated backup fuse
- No
Protection
- Energy-coordinated protection effect with regard to the terminal equipment
- No
- Degree of protection (IP)
- IP20
Logistics
- Net weight
- 1.2 kg
- Country of origin
- Bulgaria
- Customs tariff number
- 85363090
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| BE | 0 | — | — | — |