piece

Description

Surge protective devices SPD type 1- type 2 protect low-voltage consumer systems against lightning currents and surge voltages as they are tested as SPD type 1 and type 2 according to IEC 61643-11. The devices are compatible with the System pro M compact series. The SPD with "TS" are optionally equipped with a auxiliary contact. The variants with "reserve varistor" (s) offer additional protection for the system, as the SPD is not completely disconnected from the mains at the end of its service life, but with an additional smaller varistor still guarantees basic protection and the system thus until the surge arrester is replaced is still protected

Tender text

OVR Typ 1+2 (SPD) Blitz- und Überspannungsschutz Ableiter mit Reserve-Varistor und QuickSafe® Technologie erfüllen die Produktnorm DIN EN 61643-11. Die Schutzgeräte können für den Einsatz als Überspannungs-Schutzeinrichtung nach VDE 0100 Teil 443 und Teil 534, sowie im Rahmen der Blitzschutznorm VDE 0185-305 verwendet werden. Normen: IEC 61643-11 / EN 61643-11 Überspannungsableiterklasse: I, II Produkttyp: QS Anzahl Pole: 4P Art des Niederspannungsverteilsystems: TN-S, (IT) Folgestromlöschvermögen: - kA, - kA Entladestrom: 20 kA, 80 kA, 320 kA Stoßstrom: 12.5 kA, 50 kA Kurzschlussfestigkeit Icc: 100 kA Kurzschlussschutzeinrichtung: ≤ 125 A, ≤ 125 A, ≤ 160 A, ≤ 160 A Schutzpegel: 3.8 kV, 1.9 kV, 1.9 kV Breite in Teilungseinheiten: 8

Technical data

ETIM class: Combined arrester for power supply systems (EC001457)

Options

System configuration DC
Yes
System configuration IT
No
System configuration TN
No
System configuration TN-C
No
System configuration TN-C-S
No
System configuration TN-S
Yes
System configuration TT
No
System configuration other
No
Remote signalling
Yes

Electrical

Number of poles
4
Lightning impulse current (10/350 µs)
12.5 kA
Max. continuous voltage AC
- V
Max. continuous voltage DC
- V
Nominal voltage AC
- V
Nominal voltage DC
- V
Max. PV-voltage
NA V
Voltage protection level
- kV
Voltage protection level L-N
3.8 kV
Voltage protection level L-PE
1.9 kV
Voltage protection level N-PE
1.9 kV
Voltage protection level (DC+ - DC-)
NA kV
Voltage protection level (DC+/DC- - PE)
NA kV
Follow current extinguishing capability
- kA
Max. overcurrent protection device, parallel connection (fuse)
- A
Max. overcurrent protection device, series connection (fuse)
- A
Voltage switching spark gap technology
No
Overcurrent protected voltage tapping
No

Other

Specific energy (W/R)
NA kJ/Ohm
Signalling at the device
-
Test class
-

Mounting/installation

Mounting method
-

Measurements

Construction size
8 modular spacing

Connection

Max. conductor cross section solid (solid, stranded)
NA mm²
Max. conductor cross section solid (solid, stranded)
NA in²
Max. conductor cross section flexible (fine-strand)
- mm²
Max. conductor cross section flexible (fine-strand)
- in²

Model/type

Integrated backup fuse
No

Protection

Energy-coordinated protection effect with regard to the terminal equipment
No
Degree of protection (IP)
IP20

Logistics

Net weight
1.2 kg
Country of origin
Bulgaria
Customs tariff number
85363090

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)