Photo 1 of 4
RCCB 4p, 40A, 0.03A, Type B SK, Mining, N left
- Manufacturer part no.
- EAN
Ordering
- Order unit
- piece
Description
Type B residual current circuit-breakers are AC-DC sensitive. The SK characteristic limits the risk of unwanted tripping providing maximum system availability, for frequencies ranging from 0 to 150 kHz. With low tripping sensitivity at higher frequencies, our SK circuit-breakers are perfectly suited for use in facilities where preventive fire protection measures are provided by additional means. Devices in the T design are specially made for use in mining and meet the increased requirements for tripping time as per DIN EN 50628 VDE 0118-10:2016-11.
Tender text
Allstromsensitiver Fehlerstromschutzschalter (RCCB) zur Erfassung von Wechsel-, pulsierenden und glatten Gleichfehlerströmen sensitiv für Fehlerströme und Mischfrequenzen von 0 Hz bis 150 kHz mit verkürzter Auslösezeit bei einfachem Idn für z. B. Bergbauanwendungen doppelte Verdrahtungsebene oben und unten Schaltstellungsanzeige und Multifunktionsschaltknebel mit den Funktionen "ein", "aus" und "ausgelöst" (Mittelstellung) Sichtfenster für Beschriftungsetiketten Fehlerstromtyp: B Auslösekennlinientyp: SK Bemessungsfehlerstrom IΔn: 0.03 A kurzzeitverzögert (gewitterfest) Neutralleiterposition: links Breite in Teilungseinheiten: 4 Polzahl (gesamt): 4 Bemessungsspannung (AC): 230 V, 400 V Bemessungsstrom AC (typ.): 40 A Bemessungsfrequenz: 50 Hz Schraubklemme oben und unten (Laststromkreis): Anschlussquerschnitt eindrähtig: 1-Leiter: 1,5 mm² ... 50 mm²; 2-Leiter: 1,5 mm² ... 16 mm² Anschlussquerschnitt mehrdrähtig: 1-Leiter: 1,5 mm² ... 50 mm²; 2-Leiter: 1,5 mm² ... 16 mm² Anschlussquerschnitt feindrähtig: 1-Leiter: 1,5 mm² ... 50 mm²; 2-Leiter: 1,5 mm² ... 16 mm² Anschlussquerschnitt AWG, eindrähtig: 15 ... 1 Anschlussquerschnitt AWG, mehrdrähtig: 15 ... 1 Anschlussquerschnitt AWG, feindrähtig: 15 ... 1 Anschlussquerschnitt AWG, feindrähtig mit AEH: 15 ... 1 Umgebungstemperatur: min. -25 °C ... max. 40 °C Gehäuseart: Verteilereinbaugehäuse Montageart: Tragschiene (35 mm) Schutzart: IP20 (eingebaut: IP40) Abmessungen: B 72 mm (4 TE) × H 85 mm × T 75 mm Bauvorschriften/Normen: VDE 0664-10, VDE 0664-40, ÖVE/ÖNORM E 8601, DIN EN 50628 VDE 0118-10:2016-11, DIN EN 61008-1, EN 62423 Fabrikat: Doepke oder gleichwertig Artikelbezeichnung: DFS 4 040-4/0,03-B SK T Bestellnummer: 09134885 gewähltes Fabrikat/Typ: ___________/___________
Technical data
ETIM class: Residual current circuit breaker (RCCB) (EC000003)
Electrical
- Number of poles
- 4
- Rated voltage
- 400 V
- Rated current
- 40 A
- Rated fault current
- 0.03 A
- Rated insulation voltage Ui
- 400 V
- Rated impulse withstand voltage Uimp
- 4 kV
- Power loss
- 6.1 W
- Leakage current type
- B
- Short-circuit breaking capacity (Icw)
- 10 kA
- Surge current capacity
- 3 kA
- Voltage type
- AC
Mounting/installation
- Mounting method
- DIN rail
Protection
- Selective protection
- No
- Degree of protection (IP)
- IP20
- Explosion-proof
- No
Model/type
- Short-time delayed tripping
- Yes
- With interlocking device
- Yes
- Type of personal protection PRCD
- UN
Other
- Frequency
- 50 Hz
- Pollution degree
- 2
Options
- Additional equipment possible
- Yes
Measurements
- Width in number of modular spacings
- 4
- Built-in depth
- 69 mm
- Device width
- 72 mm
- Device height
- 85 mm
- Device depth
- 75 mm
Operating conditions
- Ambient temperature during operating
- -25, 40 °C
Connection
- Connectable conductor cross section multi-wired
- 1.5, 50 mm²
- Connectable conductor cross section solid-core
- 1.5, 50 mm²
Colour
- Colour
- Grey
- RAL-number (similar)
- 7035
Logistics
- Net weight
- 0.479 kg
- Country of origin
- Germany
- Customs tariff number
- 85363030
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| carton | 1 | 4014712237759 | 0.479 kg | 90 × 75 × 80 mm |
| carton | 20 | 4014712237766 | 10.17 kg | 410 × 385 × 85 mm |