Description

Circuit-breakers with residual current trip (CBR) switch high currents, protect equipment, cables and lines against overcurrent and protect people against electric shock. DFL 8 are compact devices with integrated auxiliary switch and terminals for large conductor cross-sections. Type B residual current circuit-breakers are AC-DC sensitive. Switches with the characteristic curve SK ensure fault protection and a high system availability. They are characterised by a lower response sensitivity at higher frequencies. This means that system-related faulty tripping is largely prevented. For switches of this variant, the residual response current can be individually set in levels for the application in question (0.3 A, 0.5 A, 1 A). The non-response lag time can also be adjusted in levels accordingly. Selective residual current circuit-breakers are therefore possible in systems with stacked distribution boards. Standard RCCBs are designed for circuits with 230/400 V at 50 Hz.

Tender text

Leistungsschalter mit Fehlerstromauslöser (CBR), 4polig, in Kompaktbauweise, mit kurzschlussstrombegrenzendem Kontaktsystem, mit einstellbaren thermomagnetischen Auslösern, mit Kipphebel und 3 Schaltstellungen (Aus, Ausgelöst und Ein), entsprechend IEC/EN 60947-2, DIN VDE 0660. Fehlerstromtyp: B Auslösekennlinientyp: SK Bemessungsfehlerstrom IΔn: 0.3 A, 0.5 A, 1 A kurzzeitverzögert (gewitterfest) selektive Ausführung Neutralleiterposition: links Bemessungsbetriebsspannung: 400 V AC Betriebsfrequenz: 50 Hz Bemessungsstoßspannungsfestigkeit: 4 kV Bemessungsdauerstrom: 125 A Betriebstemperatur: min. -25 °C ... max. 70 °C Mechanische Lebensdauer: 2000 Schaltspiele Elektrische Lebensdauer AC-1: 10000 Schaltspiele Überlastauslöser: 0.8 - 1 x Ir Unverzögerter Kurzschlussauslöser Ii: 6 - 10 x Iu Hilfsschalter integriert: 1 Schließer, 1 Öffner, 0 Wechsler Rahmenklemme oben und unten (Laststromkreis): Klemmbereich: min. 4 mm² ... max. 185 mm² Anschlussquerschnitt eindrähtig: 1-Leiter: 4 mm² ... 16 mm²; 2-Leiter: 4 mm² ... 16 mm² Anschlussquerschnitt mehrdrähtig: 1-Leiter: 25 mm² ... 185 mm²; 2-Leiter: 25 mm² ... 70 mm² Gehäuseart: Aufputzgehäuse Montageart: Wandmontage Schutzart: IP20 (eingebaut: IP40) Abmessungen: B 140 mm × H 291 mm × T 103 mm Bauvorschriften/Normen: DIN IEC 60755, EN 60947-2, EN 60947-2 Anhang B, VDE 0660-101 Fabrikat: Doepke oder gleichwertig Artikelbezeichnung: DFL 8 125-4/X-B SK Bestellnummer: 09179784 gewähltes Fabrikat/Typ: ___________/___________

Technical data

ETIM class: Earth leakage circuit breaker (EC000905)

Model/type

Number of poles (total)
4
Number of protected poles
3
With interlocking device
Yes

Electrical

Rated voltage
400 V
Rated insulation voltage Ui
1000 V
Rated impulse withstand voltage Uimp
4 kV
Rated current
125 A
Rated fault current
0.3 A
Leakage current type
B
Current limiting class
UN
Power loss
70.6 W
Rated short-circuit breaking capacity according to EN 61009
UN kA
Rated short-circuit breaking capacity according to IEC 60947-2
85 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1
UN kA
Surge current capacity
5 kA
Voltage type
AC
Release characteristic
Other
Overvoltage category
3

Mounting/installation

Mounting method
Surface mounting

Connection

Disconnection characteristic
Short-time delayed
Connectable conductor cross section solid-core
4, 16 mm²
Connectable conductor cross section multi-wired
25, 185 mm²

Other

Frequency
50 Hz
Pollution degree
3

Options

Concurrently switching neutral conductor
Yes
Anti-nuisance tripping version
No

Operating conditions

Ambient temperature during operating
-25, 70 °C

Measurements

Width in number of modular spacings
0
Built-in depth
149 mm

Protection

Degree of protection (IP)
IP20

Logistics

Net weight
5.86 kg
Country of origin
Germany
Customs tariff number
85363030

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
carton140147121535545.86 kg310 × 150 × 180 mm

Documents