Photo 1 of 4
Circuit-breaker with RCCB 4-pole, 0.03A, 200A@230/400V (AC), 50Hz, AC/DC sensitive, NK-Characteristic
- Manufacturer part no.
- EAN
Ordering
- Order unit
- piece
Description
Circuit-breakers with residual current trip (CBR) switch high currents, protect equipment, cables and lines against overcurrent and protect people against electric shock. DFL 8 are compact devices with integrated auxiliary switch and terminals for large conductor cross-sections. Type B residual current circuit-breakers are AC-DC sensitive. Switches with the characteristic curve NK provide classic fire protection of 300 mA at frequencies up to 150 kHz. They are optimised for facilities at risk of fire. Switches of this variant have a fixed residual response current of 30 mA for the protection of persons. They therefore provide fault and fire protection as well as additional protection (personal protection, protection in the event of direct contact). Standard RCCBs are designed for circuits with 230/400 V at 50 Hz.
Tender text
Leistungsschalter mit Fehlerstromauslöser (CBR), 4polig, in Kompaktbauweise, mit kurzschlussstrombegrenzendem Kontaktsystem, mit einstellbaren thermomagnetischen Auslösern, mit Kipphebel und 3 Schaltstellungen (Aus, Ausgelöst und Ein), entsprechend IEC/EN 60947-2, DIN VDE 0660. Fehlerstromtyp: B Auslösekennlinientyp: NK Bemessungsfehlerstrom IΔn: 0.03 A kurzzeitverzögert (gewitterfest) Neutralleiterposition: links Bemessungsbetriebsspannung: 400 V AC Betriebsfrequenz: 50 Hz Bemessungsstoßspannungsfestigkeit: 4 kV Bemessungsdauerstrom: 200 A Betriebstemperatur: min. -25 °C ... max. 70 °C Mechanische Lebensdauer: 2000 Schaltspiele Elektrische Lebensdauer AC-1: 10000 Schaltspiele Überlastauslöser: 0.8 - 1 x Ir Unverzögerter Kurzschlussauslöser Ii: 6 - 10 x Iu Hilfsschalter integriert: 1 Schließer, 1 Öffner, 0 Wechsler Rahmenklemme oben und unten (Laststromkreis): Klemmbereich: min. 4 mm² ... max. 185 mm² Anschlussquerschnitt eindrähtig: 1-Leiter: 4 mm² ... 16 mm²; 2-Leiter: 4 mm² ... 16 mm² Anschlussquerschnitt mehrdrähtig: 1-Leiter: 25 mm² ... 185 mm²; 2-Leiter: 25 mm² ... 70 mm² Gehäuseart: Aufputzgehäuse Montageart: Wandmontage Schutzart: IP20 (eingebaut: IP40) Abmessungen: B 140 mm × H 291 mm × T 103 mm Bauvorschriften/Normen: DIN IEC 60755, EN 60947-2, EN 60947-2 Anhang B, VDE 0660-101 Fabrikat: Doepke oder gleichwertig Artikelbezeichnung: DFL 8 200-4/0,03-B NK Bestellnummer: 09204783 gewähltes Fabrikat/Typ: ___________/___________
Technical data
ETIM class: Earth leakage circuit breaker (EC000905)
Model/type
- Number of poles (total)
- 4
- Number of protected poles
- 3
- With interlocking device
- Yes
Electrical
- Rated voltage
- 400 V
- Rated insulation voltage Ui
- 1000 V
- Rated impulse withstand voltage Uimp
- 4 kV
- Rated current
- 200 A
- Rated fault current
- 0.03 A
- Leakage current type
- B
- Current limiting class
- UN
- Power loss
- 120 W
- Rated short-circuit breaking capacity according to EN 61009
- UN kA
- Rated short-circuit breaking capacity according to IEC 60947-2
- 85 kA
- Rated short-circuit breaking capacity Icn according to EN 61009-1
- UN kA
- Surge current capacity
- 5 kA
- Voltage type
- AC
- Release characteristic
- Other
- Overvoltage category
- 3
Mounting/installation
- Mounting method
- Surface mounting
Connection
- Disconnection characteristic
- Short-time delayed
- Connectable conductor cross section solid-core
- 4, 16 mm²
- Connectable conductor cross section multi-wired
- 25, 185 mm²
Other
- Frequency
- 50 Hz
- Pollution degree
- 3
Options
- Concurrently switching neutral conductor
- Yes
- Anti-nuisance tripping version
- No
Operating conditions
- Ambient temperature during operating
- -25, 70 °C
Measurements
- Width in number of modular spacings
- 0
- Built-in depth
- 149 mm
Protection
- Degree of protection (IP)
- IP20
Logistics
- Net weight
- 5.84 kg
- Country of origin
- Germany
- Customs tariff number
- 85363090
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| carton | 1 | 4014712153677 | 5.84 kg | 310 × 150 × 180 mm |