Photo 1 of 3
Residual current transformer for DMRCD/DRCM, d=35mm, Type A, AC
- Manufacturer part no.
- EAN
Ordering
- Order unit
- piece
Description
Residual current transformers are used in combination with evaluation units to monitor and protect electric circuits. Series DCT transformers combine with DMRCD evaluation units to form modular residual current devices (MRCDs) as per EN 60947-2 or with DRCM evaluation units to form residual current monitors (RCMs) as per EN 62020. Only components of the same type of residual current (A or B+) can be combined. Residual current transformers with characteristic A detect sinusoidal AC currents as well as pulsating DC residual currents. The transformer covers all of the active conductors leading to the consumers and uses its output signal to illustrate the time curve of the sum of all conductor currents flowing through it. Its output signal is proportional to the residual current, which flows back to the earthing point of the supply mains via the protective earth conductor in the case of an insulation fault or via the earth.
Tender text
Differenzstrom-Erfassungseinheit DCT A, kombinierbar mit einem DMRCD 1 A zu einem modularen Fehlerstromschutzgerät (MRCD) nach EN 60947-2 und VDE 0100-530 bzw. mit einem Differenzstrommonitor DRCM 1 A zu einem Differenzstrom-Überwachungsgerät (RCM) nach EN 62020. Differenzstromerfassungscharakteristik: A, AC : Bemessungsdauerdifferenzstrom Faktor: 1.5 Bemessungskurzschlussdifferenzstrom: 10 kA Überstrombegrenzungsfaktor: 6 Frequenzbereich Ansprechdifferenzstrom Typ A: 50 Hz ... 60 Hz Frequenzbereich Ansprechdifferenzstrom Typ AC: 40 Hz ... 2 kHz Wandler geeignet für: DMRCD / DRCM Wandler primärseitig: Bemessungsspannung (AC): 0 V ... 690 V Bemessungsstrom: 125 A Bemessungsfrequenz: 50 Hz ... 60 Hz Bemessungsstoßspannungsfestigkeit: 8 kV / Kategorie IV max. Überstrom bzgl. Nichtauslösung: 6 x In Bemessungsdauerdifferenzstrom Faktor: 1.5 x In Bemessungskurzschlussdifferenzstrom: 10 kA Bemessungskurzzeitdifferenzstrom Faktor: 10 x In (für 1 s) Bemessungsstoßdifferenzstrom Faktor: 25 x In Überstrombegrenzungsfaktor: 6 Gehäuseart: Aufputzgehäuse Montageart: Wandmontage Schutzart: IP20 Abmessungen: B 85 mm × H 98 mm × T 71 mm Innendurchmesser: 35 mm Bauvorschriften/Normen: EN 62020, EN 60947-2, EN 61869-2 Fabrikat: Doepke oder gleichwertig Artikelbezeichnung: DCT A-035 Bestellnummer: 09340321 gewähltes Fabrikat/Typ: ___________/___________
Technical data
ETIM class: Current transformer (EC002048)
Model/type
- Model
- Other
- With contact protection
- Yes
- With copper rail
- No
Electrical
- Rated primary current
- 125 A
- Rated secondary current
- UN A
- Rated secondary apparent power
- UN VA
- Power consumption
- UN W
- Overcurrent limiting factor
- UN
Other
- Accuracy class
- Other
Options
- Calibrated
- No
Measurements
- Height opening
- 35, 35 mm
- Width opening
- 35, 35 mm
- Opening diameter
- 35 mm
Mounting/installation
- Snap mounting
- No
Connection
- Secondary connection
- Plug-in connection
- Number of primary inputs
- 1
Logistics
- Net weight
- 0.432 kg
- Country of origin
- Germany
- Customs tariff number
- 85043180
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| carton | 1 | 4014712241039 | 0.432 kg | 260 × 170 × 130 mm |