Skip to content
Eltracore

Photo 1 of 3

Doepke

Residual current transformer for DMRCD/DRCM, d=105mm, Type A, AC

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Description

Residual current transformers are used in combination with evaluation units to monitor and protect electric circuits. Series DCT transformers combine with DMRCD evaluation units to form modular residual current devices (MRCDs) as per EN 60947-2 or with DRCM evaluation units to form residual current monitors (RCMs) as per EN 62020. Only components of the same type of residual current (A or B+) can be combined. Residual current transformers with characteristic A detect sinusoidal AC currents as well as pulsating DC residual currents. The transformer covers all of the active conductors leading to the consumers and uses its output signal to illustrate the time curve of the sum of all conductor currents flowing through it. Its output signal is proportional to the residual current, which flows back to the earthing point of the supply mains via the protective earth conductor in the case of an insulation fault or via the earth.

Tender text

Differenzstrom-Erfassungseinheit DCT A, kombinierbar mit einem DMRCD 1 A zu einem modularen Fehlerstromschutzgerät (MRCD) nach EN 60947-2 und VDE 0100-530 bzw. mit einem Differenzstrommonitor DRCM 1 A zu einem Differenzstrom-Überwachungsgerät (RCM) nach EN 62020. Differenzstromerfassungscharakteristik: A, AC : Bemessungsdauerdifferenzstrom Faktor: 1.5 Bemessungskurzschlussdifferenzstrom: 10 kA Überstrombegrenzungsfaktor: 6 Frequenzbereich Ansprechdifferenzstrom Typ A: 50 Hz ... 60 Hz Frequenzbereich Ansprechdifferenzstrom Typ AC: 40 Hz ... 2 kHz Wandler geeignet für: DMRCD / DRCM Wandler primärseitig: Bemessungsspannung (AC): 0 V ... 690 V Bemessungsstrom: 250 A Bemessungsfrequenz: 50 Hz ... 60 Hz Bemessungsstoßspannungsfestigkeit: 8 kV / Kategorie IV max. Überstrom bzgl. Nichtauslösung: 6 x In Bemessungsdauerdifferenzstrom Faktor: 1.5 x In Bemessungskurzschlussdifferenzstrom: 10 kA Bemessungskurzzeitdifferenzstrom Faktor: 10 x In (für 1 s) Bemessungsstoßdifferenzstrom Faktor: 25 x In Überstrombegrenzungsfaktor: 6 Gehäuseart: Aufputzgehäuse Montageart: Wandmontage Schutzart: IP20 Abmessungen: B 165 mm × H 174 mm × T 71 mm Innendurchmesser: 105 mm Bauvorschriften/Normen: EN 62020, EN 60947-2, EN 61869-2 Fabrikat: Doepke oder gleichwertig Artikelbezeichnung: DCT A-105 Bestellnummer: 09340323 gewähltes Fabrikat/Typ: ___________/___________

Technical data

ETIM class: Current transformer (EC002048)

Model/type

Model
Other
With contact protection
Yes
With copper rail
No

Electrical

Rated primary current
250 A
Rated secondary current
UN A
Rated secondary apparent power
UN VA
Power consumption
UN W
Overcurrent limiting factor
UN

Other

Accuracy class
Other

Options

Calibrated
No

Measurements

Height opening
105, 105 mm
Width opening
105, 105 mm
Opening diameter
105 mm

Mounting/installation

Snap mounting
No

Connection

Secondary connection
Plug-in connection
Number of primary inputs
1

Logistics

Net weight
1.04 kg
Country of origin
Germany
Customs tariff number
85043180

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
carton140147122410531.04 kg260 × 170 × 140 mm

Documents