Photo 1 of 3
FI/LS circuit breaker combination (RCBO) 3p+N, 0.3A, 25A@230/400V (AC), B-characteristic, Type A
- Manufacturer part no.
- EAN
Ordering
- Order unit
- piece
Description
RCBOs combine residual current protection and overcurrent protection in a single device. This makes them ideal for use in distribution boards where space is limited. The rated breaking capacity of the DRCBO 4 series is 6 kA. Type A circuit-breakers detect pulsating direct current and alternating current. With tripping characteristic B, these circuit-breakers ensure reliable protection for your circuits without high inrush currents. Standard circuit-breakers are designed for circuits with 230 V or 400 V at 50 Hz.
Tender text
Netzspannungsunabhängiger Fehlerstromschutzschalter mit Überstromauslösung (RCBO) zur Erfassung von Wechselfehler- und pulsierenden Gleichfehlerströmen geeignet zum nachträglichen Anbau von Zusatzeinrichtungen Auslösecharakteristik (MCB): B Fehlerstromtyp: A Bemessungsfehlerstrom IΔn: 0.3 A Neutralleiterposition: rechts Breite in Teilungseinheiten: 4 Laststromkreis (Lasttrennkontakt): Polzahl (gesamt): 4 Bemessungsspannung (AC): 230 V, 400 V Bemessungsstrom AC (typ.): 25 A Bemessungsfrequenz: 50 Hz, 60 Hz max. Bemessungsschaltvermögen: 6 kA Bemessungskurzschlussstrom: 6 kA Bemessungsisolationsspannung: 440 V Schraubklemme oben, unten (Laststromkreis): Anschlussquerschnitt eindrähtig: 1-Leiter: 1 mm² ... 35 mm²; 2-Leiter: 1 mm² ... 10 mm² Anschlussquerschnitt mehrdrähtig: 1-Leiter: 1 mm² ... 25 mm²; 2-Leiter: 1 mm² ... 10 mm² Anschlussquerschnitt feindrähtig: 1-Leiter: 1 mm² ... 25 mm²; 2-Leiter: 1 mm² ... 10 mm² Umgebungstemperatur: min. -25 °C ... max. 40 °C Gehäuseart: Verteilereinbaugehäuse Montageart: Tragschiene (35 mm) Schutzart: IP20 (eingebaut: IP40) Abmessungen: B 70 mm (4 TE) × H 92 mm × T 74 mm Bauvorschriften/Normen: EN 61009-1, EN 61009-2-1, VDE 0664-20 Fabrikat: Doepke oder gleichwertig Artikelbezeichnung: DRCBO 4 B25/0,30/3N-A Bestellnummer: 09945116 gewähltes Fabrikat/Typ: ___________/___________
Technical data
ETIM class: Earth leakage circuit breaker (EC000905)
Model/type
- Number of poles (total)
- 4
- Number of protected poles
- 3
- With interlocking device
- No
Electrical
- Rated voltage
- 400 V
- Rated insulation voltage Ui
- 440 V
- Rated impulse withstand voltage Uimp
- 4 kV
- Rated current
- 25 A
- Rated fault current
- 0.3 A
- Leakage current type
- A
- Current limiting class
- 3
- Power loss
- 12.9 W
- Rated short-circuit breaking capacity according to EN 61009
- 6 kA
- Rated short-circuit breaking capacity according to IEC 60947-2
- UN kA
- Rated short-circuit breaking capacity Icn according to EN 61009-1
- 6 kA
- Surge current capacity
- 0.25 kA
- Voltage type
- AC
- Release characteristic
- B
- Overvoltage category
- 3
Mounting/installation
- Mounting method
- DIN rail
Connection
- Disconnection characteristic
- Undelayed
- Connectable conductor cross section solid-core
- 1, 35 mm²
- Connectable conductor cross section multi-wired
- 1, 25 mm²
Other
- Frequency
- 50/60 Hz
- Pollution degree
- 2
Options
- Concurrently switching neutral conductor
- Yes
- Anti-nuisance tripping version
- No
Operating conditions
- Ambient temperature during operating
- -25, 40 °C
Measurements
- Width in number of modular spacings
- 4
- Built-in depth
- 68 mm
Protection
- Degree of protection (IP)
- IP20
Logistics
- Net weight
- 0.509 kg
- Country of origin
- Italy
- Customs tariff number
- 85363030
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| carton | 1 | 4014712266650 | 0.509 kg | 100 × 78 × 78 mm |
| carton | 40 | 4014712268050 | 20.6 kg | 350 × 450 × 230 mm |