FI/LS circuit breaker combination (RCBO) 3p+N, 0.03A, 10A@230/400V (AC), C-characteristic, Type F, short-time delayed

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.
Checking availability…

Ordering

Order unit
piece

Description

RCBOs combine residual current protection and overcurrent protection in a single device. This makes them ideal for use in distribution boards where space is limited. The rated breaking capacity of the DRCBO 4 series is 6 kA. ►Type F circuit-breakers are sensitive to mixed frequencies.▲▼Switches for residual current type F are mains voltage-independent and record type A sinusoidal alternating and pulsating DC residual currents as well as residual currents With tripping characteristic C, these circuit-breakers ensure reliable protection for your circuits with loads that generate higher inrush peaks. Standard circuit-breakers are designed for circuits with 230 V or 400 V at 50 Hz.

Tender text

Netzspannungsunabhängiger Fehlerstromschutzschalter mit Überstromauslösung (RCBO) zur Erfassung von Wechselfehler- und pulsierenden Gleichfehlerströmen sensitiv für Fehlerströme und Mischfrequenzen von 10 Hz bis 1 kHz bei Verwendung von einphasigen elektronischen Verbrauchern geeignet zum nachträglichen Anbau von Zusatzeinrichtungen Auslösecharakteristik (MCB): C Fehlerstromtyp: F Bemessungsfehlerstrom IΔn: 0.03 A kurzzeitverzögert (gewitterfest) Neutralleiterposition: rechts Breite in Teilungseinheiten: 4 Laststromkreis (Lasttrennkontakt): Polzahl (gesamt): 4 Bemessungsspannung (AC): 230 V, 400 V Bemessungsstrom AC (typ.): 10 A Bemessungsfrequenz: 50 Hz, 60 Hz max. Bemessungsschaltvermögen: 6 kA Bemessungskurzschlussstrom: 6 kA Bemessungsisolationsspannung: 440 V Schraubklemme oben, unten (Laststromkreis): Anschlussquerschnitt eindrähtig: 1-Leiter: 1 mm² ... 35 mm²; 2-Leiter: 1 mm² ... 10 mm² Anschlussquerschnitt mehrdrähtig: 1-Leiter: 1 mm² ... 25 mm²; 2-Leiter: 1 mm² ... 10 mm² Anschlussquerschnitt feindrähtig: 1-Leiter: 1 mm² ... 25 mm²; 2-Leiter: 1 mm² ... 10 mm² Umgebungstemperatur: min. -25 °C ... max. 40 °C Gehäuseart: Verteilereinbaugehäuse Montageart: Tragschiene (35 mm) Schutzart: IP20 (eingebaut: IP40) Abmessungen: B 70 mm (4 TE) × H 92 mm × T 74 mm Bauvorschriften/Normen: EN 61009-1, EN 62423 Fabrikat: Doepke oder gleichwertig Artikelbezeichnung: DRCBO 4 C10/0,03/3N-F Bestellnummer: 09948622 gewähltes Fabrikat/Typ: ___________/___________

Technical data

ETIM class: Earth leakage circuit breaker (EC000905)

Model/type

Number of poles (total)
4
Number of protected poles
3
With interlocking device
No

Electrical

Rated voltage
400 V
Rated insulation voltage Ui
440 V
Rated impulse withstand voltage Uimp
4 kV
Rated current
10 A
Rated fault current
0.03 A
Leakage current type
F
Current limiting class
3
Power loss
6.6 W
Rated short-circuit breaking capacity according to EN 61009
6 kA
Rated short-circuit breaking capacity according to IEC 60947-2
UN kA
Rated short-circuit breaking capacity Icn according to EN 61009-1
6 kA
Surge current capacity
3 kA
Voltage type
AC
Release characteristic
C
Overvoltage category
3

Mounting/installation

Mounting method
DIN rail

Connection

Disconnection characteristic
Short-time delayed
Connectable conductor cross section solid-core
1, 35 mm²
Connectable conductor cross section multi-wired
1, 25 mm²

Other

Frequency
50/60 Hz
Pollution degree
2

Options

Concurrently switching neutral conductor
Yes
Anti-nuisance tripping version
No

Operating conditions

Ambient temperature during operating
-25, 40 °C

Measurements

Width in number of modular spacings
4
Built-in depth
68 mm

Protection

Degree of protection (IP)
IP20

Logistics

Net weight
0.499 kg
Country of origin
Italy
Customs tariff number
85363010

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
carton140147122919040.499 kg100 × 78 × 78 mm
carton40401471229209320.1 kg450 × 350 × 230 mm

Documents