Skip to content
Eltracore

Eaton

Variable frequency drive, 400 V AC, 3-phase, 45 kW, IP21, Radio interference suppression filter, Brake chopper, OLED display, FR7

Manufacturer part no.
EAN
Series
None
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Description

Frequenzumrichter, Typkenner: SPX, Bemessungsbetriebsspannung: Ue = 400 V AC, 3-phasig, 480 V AC, 3-phasig, 500 V AC, 3-phasig, Ausgangsspannung bei Ue: U2 = 400 V AC, 3-phasig, 480 V AC, 3-phasig, 500 V AC, 3-phasig, Netzspannung (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Bemessungsbetriebsstrom bei 150 % Überlast: Ie = 87 A, Bemessungsbetriebsstrom bei 110 % Überlast: Ie = 105 A, Hinweis: Überlastzyklus für 60 s alle 600 s, Zugeordnete Motorleistung Hinweis: für innen- und außenbelüftete Wechselstrommotoren mit 50 Hz bzw. 60 Hz, Überlastzyklus für 60 s alle 600 s, bei 400 V, 50 Hz, Zugeordnete Motorleistung 150 % Überlast: P = 45 kW, 110 % Überlast: P = 55 kW, 150 % Überlast: IM = 81 A, 110 % Überlast: IM = 99 A, Zugeordnete Motorleistung Hinweis: bei 440 - 480 V, 60 Hz, Zugeordnete Motorleistung 150 % Überlast: P = 60 HP, 110 % Überlast: P = 75 HP, Zugeordnete Motorleistung 150 % Überlast: IM = 77 A, 110 % Überlast: IM = 96 A, Schutzart: IP21, Feldbusanschaltung (optional): PROFIBUS-DP, LonWorks, CANopen®, DeviceNet, Modbus-TCP, BACnet/IP, Ausstattung: Funkentstörfilter, Brems-Chopper, OLED-Anzeige, Zwischenkreisdrossel, Baugröße: FR7, Normen und Bestimmungen: Allgemeine Anforderungen: IEC/EN 61800-2, EMV-Anforderungen: IEC/EN 61800-3, Anforderungen an die Sicherheit: IEC/EN 61800-5-1

Technical data

ETIM class: Frequency converter =< 1 kV (EC001857)

Electrical

Mains voltage
380, 500 V
Mains frequency
50/60 Hz
Max. output voltage
UN V
Nominal output current I2N
UN A
Relative symmetric net voltage tolerance
UN %

Connection

Number of phases input
UN
Number of phases output
UN
Number of analogue outputs
1
Number of analogue inputs
UN
Number of digital outputs
UN
Number of digital inputs
UN
With PC connection
No

Other

Max. output frequency
320 Hz
Relative symmetric net frequency tolerance
UN %

Performance

Max. output at quadratic load at rated output voltage
UN kW
Max. output at linear load at rated output voltage
UN kW

Model/type

With control element
No
Type of converter
Other

Application

Application in industrial area permitted
No
Application in domestic- and commercial area permitted
No

Communication

Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for BACnet
No
Supporting protocol for other bus systems
No
Number of HW-interfaces industrial Ethernet
UN
Number of interfaces PROFINET
UN
Number of HW-interfaces RS-232
UN
Number of HW-interfaces RS-422
UN
Number of HW-interfaces RS-485
UN
Number of HW-interfaces serial TTY
UN
Number of HW-interfaces USB
UN
Number of HW-interfaces parallel
UN
Number of HW-interfaces other
UN
With optical interface
No

Options

Integrated breaking resistance
No

Setting/control

4-quadrant operation possible
No

Protection

Degree of protection (IP)
IP21
Degree of protection (NEMA)
Other

Measurements

Height
257 mm
Width
237 mm
Depth
640 mm

Logistics

Net weight
35 kg
Country of origin
Finland
Customs tariff number
85044086

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
CS1—37.706 kg800 × 600 × 570 mm