Description
Das System XI/ON ECO ergänzt das XI/ON Standard I/O-System um preis- und platzoptimierte I/O-Module und Gateways. Die ECO-Module benötigen keine Basismodule und sind voll kompatibel zum Standard XI/ON-System. Hohe Kanaldichte (bis zu 16 DI/DO auf 13 mm), "Push-In" Federzugklemmen, 8 oder 16 Kanäle pro Modul. Die ECO-Gateways bedienen die Bussysteme CANopen, Profibus-DP und Ethernet.
Technical data
ETIM class: Fieldbus, decentr. periphery - digital I/O module (EC001599)
Electrical
- Supply voltage AC 50 Hz
- 0, 0 V
- Supply voltage AC 60 Hz
- 0, 0 V
- Supply voltage DC
- 18, 30 V
- Voltage type (supply voltage)
- DC
- Input current at signal 1
- 0 mA
- Permitted voltage at input
- 0, 0 V
- Type of voltage (input voltage)
- DC
- Output current
- 0.5 A
- Permitted voltage at output
- 0, 30 V
- Type of output voltage
- DC
Connection
- Number of digital inputs
- 0
- Number of digital outputs
- 8
- Short-circuit protection, outputs available
- Yes
- Type of electric connection
- Plug-in connection
- Fieldbus connection over separate bus coupler possible
- Yes
Options
- Digital inputs configurable
- No
- Digital outputs configurable
- No
- Radio standard Bluetooth
- No
- Radio standard WLAN 802.11
- No
- Radio standard GPRS
- No
- Radio standard GSM
- No
- Mobile communications standard 3G (UMTS)
- No
- IO link master
- No
- System accessory
- Yes
- Rack-assembly possible
- No
Model/type
- Type of digital output
- Transistor
Communication
- Number of HW-interfaces industrial Ethernet
- 0
- Number of interfaces PROFINET
- 0
- Number of HW-interfaces RS-232
- 0
- Number of HW-interfaces RS-422
- 0
- Number of HW-interfaces RS-485
- 0
- Number of HW-interfaces serial TTY
- 0
- Number of HW-interfaces parallel
- 0
- Number of HW-interfaces wireless
- 0
- Number of HW-interfaces USB
- 0
- Number of HW-interfaces other
- 1
- With optical interface
- No
- Supporting protocol for TCP/IP
- No
- Supporting protocol for PROFIBUS
- No
- Supporting protocol for CAN
- No
- Supporting protocol for INTERBUS
- No
- Supporting protocol for ASI
- No
- Supporting protocol for KNX
- No
- Supporting protocol for Modbus
- No
- Supporting protocol for Data-Highway
- No
- Supporting protocol for DeviceNet
- No
- Supporting protocol for SUCONET
- No
- Supporting protocol for LON
- No
- Supporting protocol for PROFINET IO
- No
- Supporting protocol for PROFINET CBA
- No
- Supporting protocol for SERCOS
- No
- Supporting protocol for Foundation Fieldbus
- No
- Supporting protocol for EtherNet/IP
- No
- Supporting protocol for AS-Interface Safety at Work
- No
- Supporting protocol for DeviceNet Safety
- No
- Supporting protocol for INTERBUS-Safety
- No
- Supporting protocol for PROFIsafe
- No
- Supporting protocol for SafetyBUS p
- No
- Supporting protocol for other bus systems
- Yes
Protection
- Degree of protection (IP)
- IP20
- Explosion safety category for gas
- None
- Explosion safety category for dust
- None
Other
- Time delay at signal change
- 0.2, 0.3 ms
- Appendant operation agent (Ex ia)
- No
- Appendant operation agent (Ex ib)
- No
Mounting/installation
- Suitable for rail mounting
- Yes
- Wall mounting/direct mounting
- No
- Front built-in possible
- No
Application
- Suitable for safety functions
- No
Approval/certification
- SIL according to IEC 61508
- None
Performance
- Performance level according to EN ISO 13849-1
- None
Measurements
- Width
- 13 mm
- Height
- 74.5 mm
- Depth
- 129.5 mm
Logistics
- Net weight
- 0.055 kg
- Country of origin
- Germany
- Customs tariff number
- 85389099
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| CS | 1 | — | 0.075 kg | 130 × 80 × 30 mm |
| box | 106 | — | 10.594 kg | 600 × 400 × 220 mm |
| PF | 2,160 | — | 229.88 kg | 1,200 × 800 × 1,150 mm |