ELKO EP

PRI-52

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Description

The current transformer relay, which senses the current through the passing wire, is used to diagnose a remote device (short circuit, increase of consumption), to indicate the current flow or to connect the appliances to the inverter performance in photovoltaic applications. DESCRIPTION Current transit indicator – informs about heating activation, ceramic hob, ventilator. In suitable wiring, it can act as a power cutter for the power reserve and allow you to reduce the size of the main circuit breaker (and thus the amount of payment for this circuit breaker). Hole for threaded conductor passes through the body of device. Possible to use also for sensing of current up to 600A from external current transformer. Preferred (priority) relay – two appliances (boiler and floor heating) operating on one phase, but never run together – prevention against current overload and circuit breaker tripping. Enables to save your main breaker expenses. TECHNICAL PARAMETERS Power voltage AC 230 V Output contact: 1x changeover 8 A/AC1 (AgNi, 2500 VA) Slight setting (by potentiometer ) of tripping current – range AC 0.5….25A Slight setting (by potentiometer) of delay – adjustable in range 0.5…..10s. 1-MODULE, DIN rail mounting.

Technical data

ETIM class: Current monitoring relay (EC001440)

Connection

Type of electric connection
Clip connection
Number of contacts as normally closed contact
1
Number of contacts as normally open contact
1
Number of contacts as change-over contact
1

Model/type

With detachable clamps
No

Electrical

Current measuring range
0.5, 25 A
Rated control supply voltage AC 50 Hz
230, 230
Rated control supply voltage AC 60 Hz
230, 230
Single-phase under current possible
Yes
Rated control supply voltage DC
0, 0
Three-phase under current possible
No
Voltage type for actuating
AC/DC
Single-phase overcurrent possible
Yes
Three-phase overcurrent possible
No

Options

Single-phase hysteresis possible
Yes
Three-phase hysteresis possible
No
Contains function DC-voltage under current
No
Contains function DC-voltage overcurrent
No
Function DC-current hysteresis
No
External current transformer
UN

Setting/control

Min. adjustable delay-on energization time
0.5 s
Min. adjustable off-delay time
0.5 s

Operating conditions

Max. permitted delay-on energization time
10 s
Max. permitted off-delay time
10 s

Measurements

Width
17.6 mm
Height
90 mm
Depth
64 mm