PRI-52
- Manufacturer part no.
- EAN
Ordering
- Order unit
- piece
Description
The current transformer relay, which senses the current through the passing wire, is used to diagnose a remote device (short circuit, increase of consumption), to indicate the current flow or to connect the appliances to the inverter performance in photovoltaic applications. DESCRIPTION Current transit indicator – informs about heating activation, ceramic hob, ventilator. In suitable wiring, it can act as a power cutter for the power reserve and allow you to reduce the size of the main circuit breaker (and thus the amount of payment for this circuit breaker). Hole for threaded conductor passes through the body of device. Possible to use also for sensing of current up to 600A from external current transformer. Preferred (priority) relay – two appliances (boiler and floor heating) operating on one phase, but never run together – prevention against current overload and circuit breaker tripping. Enables to save your main breaker expenses. TECHNICAL PARAMETERS Power voltage AC 230 V Output contact: 1x changeover 8 A/AC1 (AgNi, 2500 VA) Slight setting (by potentiometer ) of tripping current – range AC 0.5….25A Slight setting (by potentiometer) of delay – adjustable in range 0.5…..10s. 1-MODULE, DIN rail mounting.
Technical data
ETIM class: Current monitoring relay (EC001440)
Connection
- Type of electric connection
- Clip connection
- Number of contacts as normally closed contact
- 1
- Number of contacts as normally open contact
- 1
- Number of contacts as change-over contact
- 1
Model/type
- With detachable clamps
- No
Electrical
- Current measuring range
- 0.5, 25 A
- Rated control supply voltage AC 50 Hz
- 230, 230
- Rated control supply voltage AC 60 Hz
- 230, 230
- Single-phase under current possible
- Yes
- Rated control supply voltage DC
- 0, 0
- Three-phase under current possible
- No
- Voltage type for actuating
- AC/DC
- Single-phase overcurrent possible
- Yes
- Three-phase overcurrent possible
- No
Options
- Single-phase hysteresis possible
- Yes
- Three-phase hysteresis possible
- No
- Contains function DC-voltage under current
- No
- Contains function DC-voltage overcurrent
- No
- Function DC-current hysteresis
- No
- External current transformer
- UN
Setting/control
- Min. adjustable delay-on energization time
- 0.5 s
- Min. adjustable off-delay time
- 0.5 s
Operating conditions
- Max. permitted delay-on energization time
- 10 s
- Max. permitted off-delay time
- 10 s
Measurements
- Width
- 17.6 mm
- Height
- 90 mm
- Depth
- 64 mm