CRM-46/230V
- Manufacturer part no.
- EAN
Ordering
- Order unit
- piece
Description
• Staircase switch enables delayed switching off of lighting on stairs, corridors, entrances, common areas or for delayed running of fans in the toilet or bathroom. • The intelligent staircase switch off ers similar application possibilities as the CRM-4, while it is possible to extend the delay for functions a, b repeatedly by briefl y pressing the control button (s). Each short press multiplies the time set by the potentiometer, i.e. setting the potentiometer to 2 minutes with three presses extends the delay up to 6 minutes. The maximum value of such an extended delay will always be 30 minutes, regardless of the number of presses. • Long press (>2 s) can switch off the output prematurely and end the ongoing delay. • Control input with the possibility of loading up to 100 mA load (glim lamp, LED in the button, etc.). • Function (selectable by potentiometer on the front panel) a – STAIRCASE SWITCH, programmable with signalization b – STAIRCASE SWITCH, programmable without signalization c – MEMORY LATCH (press to switch on, press to switch off ) d – MEMORY LATCH with delay ON (permanently closed) - e.g. during cleaning, moving OFF (permanently open) - e.g. when replacing luminaires • Adjustable time range 0.5 to 10 minutes. • Handles surge currents up to 80A. • 3-wire or 4-wire connection (input S can be controlled by potential A1 or A2) .
Technical data
ETIM class: Staircase lighting timer (EC000297)
Model/type
- Function
- Electronic with multi function
Mounting/installation
- Mounting method
- DIN rail
Measurements
- Width in number of modular spacings
- 1
- Built-in depth
- 64 mm
Connection
- Number of contacts as normally open contact
- UN
- Number of contacts as normally closed contact
- UN
- Number of contacts as change-over contact
- UN
Electrical
- Control voltage 1
- 230, 230 V
- Type of control voltage 1
- AC
- Frequency control voltage 1
- 50, 60 Hz
- Control voltage 2
- 0, 0 V
- Type of control voltage 2
- AC
- Frequency control voltage 2
- 0, 0 Hz
- Rated switch current
- 16 A
- Max. switching current (cos phi = 0.6)
- 0 A
- Push button glow-lamp current
- 0 mA
- Supply voltage
- 230, 230 V
- Voltage type (supply voltage)
- AC
- Max. incandescent lamp load
- 0 W
- Max. load fluorescent lamp
- 0 VA
- Max. load fluorescent lamp (Duo circuit)
- 0 VA
- Max. load fluorescent lamp (parallel compensated)
- 0 VA
Other
- Release-delay
- 0.5, 10 min
- Wiring system
- 3 and 4 wire configuration
- Pre-warning of switching-off
- None
- Repetitive
- None
Options
- Current surge function selectable
- No