Description

• Staircase switch enables delayed switching off of lighting on stairs, corridors, entrances, common areas or for delayed running of fans in the toilet or bathroom. • The intelligent staircase switch off ers similar application possibilities as the CRM-4, while it is possible to extend the delay for functions a, b repeatedly by briefl y pressing the control button (s). Each short press multiplies the time set by the potentiometer, i.e. setting the potentiometer to 2 minutes with three presses extends the delay up to 6 minutes. The maximum value of such an extended delay will always be 30 minutes, regardless of the number of presses. • Long press (>2 s) can switch off the output prematurely and end the ongoing delay. • Control input with the possibility of loading up to 100 mA load (glim lamp, LED in the button, etc.). • Function (selectable by potentiometer on the front panel) a – STAIRCASE SWITCH, programmable with signalization b – STAIRCASE SWITCH, programmable without signalization c – MEMORY LATCH (press to switch on, press to switch off ) d – MEMORY LATCH with delay ON (permanently closed) - e.g. during cleaning, moving OFF (permanently open) - e.g. when replacing luminaires • Adjustable time range 0.5 to 10 minutes. • Handles surge currents up to 80A. • 3-wire or 4-wire connection (input S can be controlled by potential A1 or A2) .

Technical data

ETIM class: Staircase lighting timer (EC000297)

Model/type

Function
Electronic with multi function

Mounting/installation

Mounting method
DIN rail

Measurements

Width in number of modular spacings
1
Built-in depth
64 mm

Connection

Number of contacts as normally open contact
UN
Number of contacts as normally closed contact
UN
Number of contacts as change-over contact
UN

Electrical

Control voltage 1
230, 230 V
Type of control voltage 1
AC
Frequency control voltage 1
50, 60 Hz
Control voltage 2
0, 0 V
Type of control voltage 2
AC
Frequency control voltage 2
0, 0 Hz
Rated switch current
16 A
Max. switching current (cos phi = 0.6)
0 A
Push button glow-lamp current
0 mA
Supply voltage
230, 230 V
Voltage type (supply voltage)
AC
Max. incandescent lamp load
0 W
Max. load fluorescent lamp
0 VA
Max. load fluorescent lamp (Duo circuit)
0 VA
Max. load fluorescent lamp (parallel compensated)
0 VA

Other

Release-delay
0.5, 10 min
Wiring system
3 and 4 wire configuration
Pre-warning of switching-off
None
Repetitive
None

Options

Current surge function selectable
No