Is used to control lights on the basis of ambient light intensity. Used for switching street illumination and garden lights, illumination of advertisements, shop windows, etc. Level of ambient intensity is monitored by an external sensor SKS-100 and output is switched according to set level on the device. Control input for additional control, e.g. time switch, preswitch etc. Level of illumination adjustable in two ranges: 1 - 100 lx and 100 - 50000 lx. Adjustable time delay to eliminate short term fluctuation in illumination. External sensor IP65 suitable for mounting on the wall (cover and holder of a sensor are a part of the package). Output: 1x CO, 16 A Housing: 1-MODULE Supply voltage (frequency): AC/DC 12-240 V (AC 50/60 Hz); AC 230 V (50/60 Hz) Sensor: external, SKS-100 Adjustable light intensity: 1 - 50 000 lx (in 2 ranges) Dimensions: 90 x 17.6 x 64 mm (3.5˝ x 0.7˝ x 2.5˝)
Technical data
ETIM class: Twilight switch for distribution board (EC001645)
Electrical
- Rated voltage
- 230 V
- Max. incandescent lamp load
- 1000 W
- Max. load fluorescent lamp
- 4000 VA
- Max. load fluorescent lamp (Duo circuit)
- 0 VA
- Max. load fluorescent lamp (parallel compensated)
- 0 VA
- Max. switching current (cos phi = 0.6)
- 0 A
- Rated switch current
- 16 A
- Rated voltage light sensor
- 0 V
Other
- Rated frequency
- 50, 60 Hz
Setting/control
- Adjustment range brightness value
- 1, 50000 lx
Model/type
- With programmable overnight shutoff
- No
Options
- Push button input
- Yes
Measurements
- Max. conductor length light sensor
- 50 m
- Width in number of modular spacings
- 1
- Built-in depth
- 64 mm
Protection
- Protection class light sensor
- II
- Degree of protection (IP)
- IP20
- Degree of protection (IP) light sensor
- IP65
Mounting/installation
- Mounting method light sensor
- Other
- Mounting method
- DIN rail