Description

Heat pump designed and manufactured in France; French savoir-faire combined with manufacturing at local factories.Compact, comprehensive control unit for all your heating, cooling, and remote DHW needs.Heating capacity increases as air temperature decreasesEfficient, with a standard Coefficient of Performance of up to 4.8*, and incredibly quiet thanks to the intricate design. Compressor with a 5-year guarantee*

Technical data

ETIM class: Heat pump (air/water) monobloc type (EC012034)

Other

Device emplacement
Outdoor positioning
Kind of optimization
Other
Modulation percentage
85, 85 %
Refrigerant pre-charge
0.42 kg
Frequency
50 Hz

Performance

Heating capacity at 7/35 °C according to EN 14511
4.06 kW
COP at 7/35 °C according to EN 14511
4.59
COPd at Tj = +7 °C
6.57
Air volume
0, 3500 m³/h
SCOP low temperature application (35 °C) at average conditions
4.72
SCOP medium temperature application (55 °C) at average conditions
3.48

Application

Suitable for additional heating central heating
No
Suitable for hot tap water
No
Suitable for active cooling
No
Suitable for swimming pool water heating
No

Setting/control

Room temperature control
No
Type of regulation
On/Off
External controller required
No
Hot tap water control integrated
Yes
Regulation for central heating boiler control
No
Regulation for buffer tank control
No
Remote operation
Yes
Speed control pump (system pump)
External
Type of speed control (system pump)
Other

Connection

Swimming pool controls
No
Data transfer via bus connection
Yes
Connection and control multiple output systems possible
No

Model/type

Modulating compressor
Yes
Type of refrigerant
R290
Type of pump (system pump)
Energy saving
Sofstarter built-in
Yes

Energy efficiency/environmental

Global warming potential (GWP)
3
Sound performance level according to EN 12102 at 0/35 °C
52 dB
ηs, h (low temperature application (35 °C) at average conditions)
186 %
Energy efficiency class space heating (35 °C) at average conditions
A+++
ηs, h (medium temperature application (55 °C) at average conditions)
136 %
Energy efficiency class space heating (55 °C) at average conditions
A++

Electrical

Connection voltage
207, 244 V
Number of phases
1
Type voltage pump (system pump)
AC

Measurements

Width
1035 mm
Height
820 mm
Depth
484 mm
Weight
81 kg

Operating conditions

Air temperature
-20, 40 °C
Max. heating water supply temperature
70 °C

Protection

Degree of protection (IP)
IPX4

Options

Cascadable
No

Communication

Data transfer via USB
Yes
Data transfer via internet
No

Logistics

Customs tariff number
84186100