Skip to content
Eltracore
No photo yet

Jung

Energy detector, 3-gang, for rail mounting

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Description

Rail mounting device, 4 rail units ETS product family: Physical sensors Product type: Energy detector Product characteristics The energy detector has three channels for connecting loads to up to three separate phases with a common neutral conductor. Each channel can measure: Voltage (eff.) Current (eff.) Active power Reactive power   Additionally, the active power and reactive power of all channels will be summed up and displayed as three-phase power values along with the mains frequency. According to the parameterisation the measured values will be transmitted on the KNX bus, either cyclically and / or when the value changes. An additional telegram will be transmitted if certain values exceed or fall below a specified limit.   The following meters exist for each channel and for the three-phase values: 1 x energy meter total 1 x energy meter ¼ h value 3 x energy meter n 3 x energy intermediate meter n   New in version 01: Direct measurement (without transformer) Transformer measurement (with external 75 A transformer, ratio 75:5, e.g. Phoenix Contact order key 2277611)

Tender text

Energy detector 3-gang KNX energy detector, 3-gang Product characteristics The energy detector has three channels for connecting loads to up to three separate phases with a common neutral conductor. Each channel can measure: ■ Voltage (eff.) ■ Current (eff.) ■ Active power ■ Reactive power Additionally, the active power and reactive power of all channels will be summed up and displayed as three-phase power values along with the mains frequency. According to the parameterisation the measured values will be transmitted on the KNX bus, either cyclically and / or when the value changes. An additional telegram will be transmitted if certain values exceed or fall below a specified limit. The following meters exist for each channel and for the three-phase values: ■ 1 x energy meter total ■ 1 x energy meter ¼ h value ■ 3 x energy meter n ■ 3 x energy intermediate meter n New in version 01: ■ Direct measurement (without transformer) ■ Transformer measurement (with external 75 A transformer, ratio 75:5, e.g. Phoenix Contact order key 2277611) Technical data Power supply via E1/N Rated voltage: AC 110 ... 240 V ~ Mains frequency: 50/60 Hz Power consumption: max. 2 W Inputs E1 ... E3 Rated voltage range: AC 110 ... 240 V ~ Rated current range: 4 mA ... 16 A Rated frequency: 50/60 Hz Measurands: voltage (rms value) current (rms value) frequency active power (signed +/-) reactive power (signed +/-) active energy (signed +/-) External transformer Transformation ratio: 75:5 Secondary current: 0 ... 5 A Accuracy: Direct measurement (without transformer): 1 % of 200 mA ... 16 A Transformer measurement (75 A transformer, class 1): 2 % of 7.5 A ... 75 A Pulses LED: Direct measurement (without transformer): 6400 / kWh Transformer measurement (75 A transformer): 427 / kWh Pulse duration: 4.9 ms Power loss Voltage measurement: ≤ 0.03 W / phase Current measurement: ≤ 0.8 W / phase Power consumption from mains: < 1 W Connection Connection mode: screw terminals single wire: 1 x 0.5 ... 2.5 mm2 stranded without ferrule: 1 x 0.5 ... 2.5 mm2 stranded with ferrule: 1 x 0.5 ... 2.5 mm2 Ambient temperature: −5 ... +45 °C Storage/transport temperature: −25 ... +70 °C Mounting width: 72 mm (4 rail units) KNX medium: TP 256 Rated voltage KNX: DC 21 ... 32 V SELV Current consumption KNX: typical 10 mA Connection, KNX: terminal Manufacturer: JUNG Ref.-no.: 2103 REG ES

Technical data

ETIM class: Physical sensor for bus system (EC000926)

Communication

Bus system KNX
Yes
Bus system KNX-RF (Radio Frequency)
No
Bus system radio frequency
No
Bus system LON
No
Bus system Powernet
No
Other bus systems
-

Options

Radio frequency bidirectional
-
Acoustic signal
-
Weather station
-

Model/type

Model
Other
With DCF77
-
With heating
-

Mounting/installation

Mounting method
DRA (DIN-rail adaptor)

Connection

With bus connection
Yes
Analogue input
Yes
Number of binary inputs
0

Colour

Colour
-
RAL-number (similar)
-

Protection

Degree of protection (IP)
-

Logistics

Country of origin
Germany
Customs tariff number
90303370

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet1—0.268 kg96 × 78 × 92 mm

Documents