Area / line coupler
- Manufacturer part no.
- EAN
Ordering
- Order unit
- piece
Description
Rail mounting device, 2 rail units ETS product family: System components Product type: Line coupler KNX Data Secure compatible with ETS 5.7.3 or higher Function: The coupler connects two KNX data lines and ensures the electrical separation of these lines from one another. The definite functions of the device are defined by addressing and parameterisation. Line coupler: Connection of a line with a main line. Alternatively with or without filter function. The coupler belongs logically to the subordinate line (here: line). Area coupler: Connection of a main line and an area line. Alternatively with or without filter function. The coupler belongs logically to the subordinate line (here: main line). Amplifier: Preparation and repetition of telegrams on a line, no filter function. Division of a line into max. 4 independent line segments (max. 3 line amplifiers connected in parallel per line). Each line segment requires a separate power supply including a choke.
Tender text
Area / line coupler KNX area / line coupler ■ KNX Data Secure compatible with ETS 5.7.3 or higher Function: The coupler connects two KNX data lines and ensures the electrical separation of these lines from one another. The definite functions of the device are defined by addressing and parameterisation. Line coupler: Connection of a line with a main line. Alternatively with or without filter function. The coupler belongs logically to the subordinate line (here: line). Area coupler: Connection of a main line and an area line. Alternatively with or without filter function. The coupler belongs logically to the subordinate line (here: main line). Amplifier: Preparation and repetition of telegrams on a line, no filter function. Division of a line into max. 4 independent line segments (max. 3 line amplifiers connected in parallel per line). Each line segment requires a separate power supply including a choke. Technical data KNX medium: TP 256 Power supply: 21 ... 32 V DC from superordinate line Current consumption superordinate line: approx. 6 mA subordinate line: approx. 8 mA Connection mode: terminal Mounting: on DIN rail Ambient temperature: −5 ... +45 °C Storing temperature: −25 ... +70 °C Protection class: III acc. EN 61 140 Mounting width: 36 mm (2 rail units) Manufacturer: JUNG Ref.-no.: 2142 REG
Technical data
ETIM class: Area/line coupler for bus system (EC000673)
Communication
- Bus system KNX
- Yes
- Bus system KNX-RF (Radio Frequency)
- No
- Bus system radio frequency
- No
- Bus system LON
- -
- Bus system Powernet
- -
- Other bus systems
- -
Mounting/installation
- Mounting method
- DRA (DIN-rail adaptor)
Measurements
- Width in number of modular spacings
- 2
Logistics
- Country of origin
- Germany
- Customs tariff number
- 85371098
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| packet | 1 | — | 0.103 kg | 90 × 55 × 77 mm |