Jung

Multi station, AC 250 V ~

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Description

Rail mounting device, 4 rail units Intended use Switching of electrical loads with floating contacts Switching of electrically-driven blinds, shutters, awnings and similar hangings Switching of electrothermal drives Polling of conventional switching or push-button contacts, window contacts etc. in KNX systems, for reporting of states, meter levels, operation of loads, etc. Polling of external temperature sensors for heating control Logic functions to control building functions Mounting on DIN rail according to EN 60715 in distribution boxes   Product characteristics Actuator functions: switching, blinds, electrothermal drives Actuator function can be switched in pairs Integrated push-button interface with 6 inputs 2 integrated room temperature controllers 2 inputs for temperature sensors (ref.-no. FF 7.8) Outputs can be operated manually, construction site mode Feedback in manual mode and in bus mode Scene function Disabling of individual outputs manually or via bus   Switching function Max. 6 switching outputs Operation as NO or NC contacts Logic operation and forcing function Feedback function Central switching function with collective feedback Time functions: switch-on delay, switch-off delay, staircase lighting timer with pre-warning function Blinds function Max. 3 blinds outputs Suitable for 230 V AC motors Blind/shutter position directly controllable Slat position directly controllable Feedback of movement status, blind/shutter position and slat position Forced position through higher-level controller Safety function: rain alarm, frost alarm, 3 independent wind alarms Sun protection function Function of valve drives Max. 2 outputs for electrothermal drives Switching operation or PWM operation Actuators with characteristics "normally open" or "normally closed" can be controlled Emergency operation in case of bus voltage failure for summer and winter Protection against jamming valves Forced position Cyclical monitoring of the input signals can be parameterised   Heating controller 2 internal controllers to control two independent rooms Control for heating or cooling, optionally with additional level On-off, PWM or PI control Predefined heating types (hot water heating, fan coil unit ...) or individual parameters possible   Inputs 6 inputs for push-buttons Input functions: switching, dimming, blinds control, light scene extension unit, brightness or temperature value transmitter 2 inputs for external temperature sensors   Logic functions Up to 10 logic operations with up to 8 inputs each, e.g. for AND, OR and XOR operations Conversion of data point types, e.g. from 1-bit to 8-bit Comparative operations, e.g. <, >, ≤, ≥ Arithmetic functions, e.g. +, –, *, :

Tender text

Multi station KNX multi station Intended use &#x25a0; Switching of electrical loads with floating contacts &#x25a0; Switching of electrically-driven blinds, shutters, awnings and similar hangings &#x25a0; Switching of electrothermal drives &#x25a0; Polling of conventional switching or push-button contacts, window contacts etc. in KNX systems, for reporting of states, meter levels, operation of loads, etc. &#x25a0; Polling of external temperature sensors for heating control &#x25a0; Logic functions to control building functions &#x25a0; Mounting on DIN rail according to EN 60715 in distribution boxes Product characteristics &#x25a0; Actuator functions: switching, blinds, electrothermal drives &#x25a0; Actuator function can be switched in pairs &#x25a0; Integrated push-button interface with 6 inputs &#x25a0; 2 integrated room temperature controllers &#x25a0; 2 inputs for temperature sensors (ref.-no. FF 7.8) &#x25a0; Outputs can be operated manually, construction site mode &#x25a0; Feedback in manual mode and in bus mode &#x25a0; Scene function &#x25a0; Disabling of individual outputs manually or via bus Switching function &#x25a0; Max. 6 switching outputs &#x25a0; Operation as NO or NC contacts &#x25a0; Logic operation and forcing function &#x25a0; Feedback function &#x25a0; Central switching function with collective feedback &#x25a0; Time functions: switch-on delay, switch-off delay, staircase lighting timer with pre-warning function Blinds function &#x25a0; Max. 3 blinds outputs &#x25a0; Suitable for 230 V AC motors &#x25a0; Blind/shutter position directly controllable &#x25a0; Slat position directly controllable &#x25a0; Feedback of movement status, blind/shutter position and slat position &#x25a0; Forced position through higher-level controller &#x25a0; Safety function: rain alarm, frost alarm, 3 independent wind alarms &#x25a0; Sun protection function Function of valve drives &#x25a0; Max. 2 outputs for electrothermal drives &#x25a0; Switching operation or PWM operation &#x25a0; Actuators with characteristics &quot;normally open&quot; or &quot;normally closed&quot; can be controlled &#x25a0; Emergency operation in case of bus voltage failure for summer and winter &#x25a0; Protection against jamming valves &#x25a0; Forced position &#x25a0; Cyclical monitoring of the input signals can be parameterised Heating controller &#x25a0; 2 internal controllers to control two independent rooms &#x25a0; Control for heating or cooling, optionally with additional level &#x25a0; On-off, PWM or PI control &#x25a0; Predefined heating types (hot water heating, fan coil unit ...) or individual parameters possible Inputs &#x25a0; 6 inputs for push-buttons &#x25a0; Input functions: switching, dimming, blinds control, light scene extension unit, brightness or temperature value transmitter &#x25a0; 2 inputs for external temperature sensors Logic functions &#x25a0; Up to 10 logic operations with up to 8 inputs each, e.g. for AND, OR and XOR operations &#x25a0; Conversion of data point types, e.g. from 1-bit to 8-bit &#x25a0; Comparative operations, e.g. <, >, &le;, &ge; &#x25a0; Arithmetic functions, e.g. +, &ndash;, *, : Technical data KNX medium: TP 256 Rated voltage KNX: DC 21 ... 32 V SELV Current consumption KNX: max. 20 mA Current consumption KNX: min. 4 mA Connection, KNX: terminal Power loss: max. 6 W Ambient temperature: &minus;5 ... +45 &deg;C Storage/transport temperature: &minus;25 ... +70 &deg;C Relay outputs Contact type: floating relay contacts (&mu; contact) Switch type: NO contact Switching voltage: AC 250 V ~ Min. switching current AC: 100 mA Switching current AC1 (cos φ &gt; 0.8): 16 A Switching current AC3 (cos φ &lt; 0.8): 6 A Fluorescent lamps: 16 AX Switch-on current 200 &micro;s: max. 800 A Switch-on current 20 ms: max. 165 A Switching voltage DC: DC 12 ... 24 V Switching current DC 24 V: 6 A Connected load, 230 V Ohmic load: 3000 W Blind / Fan motors: 1380 VA Lamp loads 230 V Incandescent lamps: 3000 W HV halogen lamps: 2500 W HV LED lamps: max. 400 W Electronic transformers: 1500 W Inductive transformers: 1200 VA Fluorescent lamps T5/T8 non-compensated: 1000 W parallel compensated: 1160 W / 140 &micro;F lead-lag circuit: 2,300 W / 140 &micro;F Compact fluorescent lamps non-compensated: 1000 W parallel compensated: 1160 W / 140 &micro;F Mercury vapour lamps non-compensated: 1000 W parallel compensated: 1160 W / 140 &micro;F Electrothermal valve drives Cycle time: min. 15 min Connection, load Connection mode: screw terminals single wire: 1 x 0.5 ... 4 mm2 stranded without ferrule: 1 x 0.5 ... 4 mm2 stranded with ferrule: 1 x 0.5 ... 2.5 mm2 Inputs Rated voltage: DC 3.3 V SELV Signal duration: min. 100 ms NO contacts: max. 50 NC contacts: max. 50 Cable length: max. 30 m For cable lengths &gt; 3 m, use shielded cables. Connection, inputs: Connection mode: screw terminals single wire: 1 x 0.08 ... 1.5 mm2 stranded without ferrule: 1 x 0.08 ... 1 mm2 stranded with ferrule: 1 x 0.14 ... 0.5 mm2 Mounting width: 72 mm (4 rail units) Manufacturer: JUNG Ref.-no.: 23066 REGHE

Technical data

ETIM class: Multi operating device for bus system (EC001585)

Communication

Bus system KNX
Yes
Bus system KNX-RF (Radio Frequency)
No
Bus system KNX Secure
No
Bus system KNX Secure-RF (Radio Frequency)
No
Bus system radio frequency
No
Bus system LON
No
Bus system Powernet
No
Other bus systems
-

Options

Radio frequency bidirectional
-
Status-LED
Yes
IR sensor
No
Presence button
No
Central functional unit for senders/actuators
-

Mounting/installation

Mounting method
DRA (DIN-rail adaptor)

Measurements

Width in number of modular spacings
4
Min. depth of built-in installation box
- mm

Setting/control

Number of actuation points
-
Manual set point setting
No

Model/type

With display
No
With temperature controller
-
With integrated DCF77 receiver
No
With time switch clock
No
With anti-theft/dismantling protection
No
Temperature controller
true

Material

Material
Plastic
Material quality
-
Surface protection
-
Surface finishing
-

Colour

Colour
-
RAL-number (similar)
-
Transparent
-

Protection

Degree of protection (IP)
-

Connection

With bus connection
Yes

Logistics

Net weight
0.256 kg
Country of origin
Germany
Customs tariff number
85176200

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet1—0.305 kg95 × 96 × 77 mm