Skip to content
Eltracore
No photo yet

Jung

Basic heating actuator, 6-gang, AC 24 / 230 V ~, 50/60 Hz, REG, 4 TE

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.
Checking availability…

Ordering

Order unit
piece

Description

Rail mounting device, 4 rail units 6 outputs "TRIAC" ETS product family: Heating, A/C, Ventilation Product type: Valve Intended use Switching of electrothermal actuators for heaters or cooling ceilings Installation in distribution boxes on DIN rail according to EN 60715   Product characteristics Switching operation or PWM operation Actuators with characteristics opened or closed without power controllable Valve drives for 230 V or 24 V controllable Disabling of individual outputs via bus Overload-protected, short circuit-protected Protection against jamming valves Cyclical monitoring of the input signals can be parameterised Feedback via bus, e.g. in case of mains failure, overload or sensor failure

Tender text

Basic heating actuator 6-gang KNX basic heating actuator, 6-gang Intended use ■ Switching of electrothermal actuators for heaters or cooling ceilings ■ Installation in distribution boxes on DIN rail according to EN 60715 Product characteristics ■ Switching operation or PWM operation ■ Actuators with characteristics opened or closed without power controllable ■ Valve drives for 230 V or 24 V controllable ■ Disabling of individual outputs via bus ■ Overload-protected, short circuit-protected ■ Protection against jamming valves ■ Cyclical monitoring of the input signals can be parameterised ■ Feedback via bus, e.g. in case of mains failure, overload or sensor failure Technical data Power loss: max. 1 W Rated voltage KNX: DC 21 ... 32 V SELV Power consumption KNX: max. 250 mW Ambient temperature: −5 ... +45 °C Storage/transport temperature: −25 ... +70 °C Heating outputs Contact type: semiconductor (triac), ε Switching voltage: AC 24 / 230 V ~ Mains frequency: 50/60 Hz Switching current: 5 ... 160 mA Switch-on current: max. 1.5 A (2 s) Switch-on current: max. 0.3 A (2 min) Number of drives per output 230 V drives: max. 4 24 V drives: max. 2 Mounting width: 72 mm (4 rail units) Connection, outputs: screw terminals single wire: 1 x 0.5 ... 4 mm2 stranded without ferrule: 1 x 0.5 ... 4 mm2 stranded with ferrule: 1 x 0.5 ... 2.5 mm2 Manufacturer: JUNG Ref.-no.: 2336 REG HZ B

Technical data

ETIM class: Heating actuator for bus system (EC001586)

Communication

Bus system KNX
Yes
Bus system KNX-RF (Radio Frequency)
No
Bus system radio frequency
No
Bus system LON
-
Bus system Powernet
-
Other bus systems
-

Options

Radio frequency bidirectional
-
Bus module detachable
-
Correcting variable consistent
-
Correcting variable switching
-
Manual switch
-

Mounting/installation

Mounting method
-

Measurements

Width in number of modular spacings
4
Min. depth of built-in installation box
- mm

Connection

With bus connection
Yes
Number of outputs
6
Number of binary inputs
-

Protection

Valve protection function
-
Degree of protection (IP)
IP20

Electrical

Max. switching current (resistive load)
- A
Max. output current
- A
Switching voltage
- V

Logistics

Country of origin
Germany
Customs tariff number
85371098

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet1—0.234 kg95 × 96 × 77 mm

Documents