Heating actuator, 6-gang
- Manufacturer part no.
- EAN
Ordering
- Order unit
- piece
Description
Rail mounting device, 4 rail units 6 outputs "TRIAC" with manual electronic operation and LED status indication ETS product family: Heating, A/C, Ventilation Product type: Valve Intended use Switching of electrothermal actuators for heaters or cooling ceilings Installation in distribution boxes on DIN rail according to EN 60715 Product characteristics Switching operation or PWM operation Actuators with characteristics "normally open" or "normally closed" can be controlled Valve drives for 230 V or 24 V controllable Outputs can be operated manually, construction site mode Feedback in manual mode and in bus mode Disabling of individual outputs manually or via bus Overload-protected, short circuit-protected; error indication with LED Protection against jamming valves Forced position Various setpoints for forced position or emergency operation in case of bus failure for summer or winter Cyclical monitoring of the input signals can be parameterised Feedback via bus, e.g. in case of mains failure, overload or sensor failure
Tender text
Heating actuator 6-gang KNX heating actuator, 6-gang Intended use ■ Switching of electrothermal actuators for heaters or cooling ceilings ■ Installation in distribution boxes on DIN rail according to EN 60715 Product characteristics ■ Switching operation or PWM operation ■ Actuators with characteristics "normally open" or "normally closed" can be controlled ■ Valve drives for 230 V or 24 V controllable ■ Outputs can be operated manually, construction site mode ■ Feedback in manual mode and in bus mode ■ Disabling of individual outputs manually or via bus ■ Overload-protected, short circuit-protected; error indication with LED ■ Protection against jamming valves ■ Forced position ■ Various setpoints for forced position or emergency operation in case of bus failure for summer or winter ■ Cyclical monitoring of the input signals can be parameterised ■ Feedback via bus, e.g. in case of mains failure, overload or sensor failure Technical data Rated voltage: AC 110 ... 230 V ~, 50/60 Hz Stand-by power: max. 0.4 W Power loss: max. 1 W KNX medium: TP 256 Rated voltage KNX: DC 21 ... 32 V SELV Power consumption KNX: max. 250 mW Ambient temperature: −5 ... +45 °C Storage/transport temperature: −25 ... +70 °C Heating outputs Contact type: semiconductor (triac), ε Switching voltage: AC 24 / 230 V ~ Mains frequency: 50/60 Hz Switching current: 5 ... 160 mA Switch-on current: max. 1.5 A (2 s) Switch-on current: max. 0.3 A (2 min) Number of drives per output 230 V drives: max. 4 24 V drives: max. 2 Mounting width: 72 mm (4 rail units) Connection, outputs Connection mode: screw terminals single wire: 1 x 0.5 ... 4 mm2 stranded without ferrule: 1 x 0.5 ... 4 mm2 stranded with ferrule: 1 x 0.5 ... 2.5 mm2 Manufacturer: JUNG Ref.-no.: 2336 REG HZ HE
Technical data
ETIM class: Heating actuator for bus system (EC001586)
Communication
- Bus system KNX
- -
- Bus system KNX-RF (Radio Frequency)
- -
- Bus system radio frequency
- -
- Bus system LON
- -
- Bus system Powernet
- -
- Other bus systems
- -
Options
- Radio frequency bidirectional
- -
- Bus module detachable
- -
- Correcting variable consistent
- -
- Correcting variable switching
- -
- Manual switch
- -
Mounting/installation
- Mounting method
- -
Measurements
- Width in number of modular spacings
- 4
- Min. depth of built-in installation box
- - mm
- Number of binary inputs
- -
Protection
- Valve protection function
- -
- Degree of protection (IP)
- IP20
Electrical
- Max. switching current (resistive load)
- - A
- Max. output current
- - A
- Switching voltage
- - V
Connection
- Number of outputs
- 6
Logistics
- Country of origin
- Germany
- Customs tariff number
- 85371098
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| packet | 1 | — | 0.285 kg | 95 × 96 × 77 mm |