Skip to content
Eltracore
No photo yet

Jung

Heating actuator, 6-gang

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Description

Rail mounting device, 4 rail units 6 outputs "TRIAC" with manual electronic operation and LED status indication ETS product family: Heating, A/C, Ventilation Product type: Valve Intended use Switching of electrothermal actuators for heaters or cooling ceilings Installation in distribution boxes on DIN rail according to EN 60715   Product characteristics Switching operation or PWM operation Actuators with characteristics "normally open" or "normally closed" can be controlled Valve drives for 230 V or 24 V controllable Outputs can be operated manually, construction site mode Feedback in manual mode and in bus mode Disabling of individual outputs manually or via bus Overload-protected, short circuit-protected; error indication with LED Protection against jamming valves Forced position Various setpoints for forced position or emergency operation in case of bus failure for summer or winter Cyclical monitoring of the input signals can be parameterised Feedback via bus, e.g. in case of mains failure, overload or sensor failure

Tender text

Heating actuator 6-gang KNX heating actuator, 6-gang Intended use ■ Switching of electrothermal actuators for heaters or cooling ceilings ■ Installation in distribution boxes on DIN rail according to EN 60715 Product characteristics ■ Switching operation or PWM operation ■ Actuators with characteristics "normally open" or "normally closed" can be controlled ■ Valve drives for 230 V or 24 V controllable ■ Outputs can be operated manually, construction site mode ■ Feedback in manual mode and in bus mode ■ Disabling of individual outputs manually or via bus ■ Overload-protected, short circuit-protected; error indication with LED ■ Protection against jamming valves ■ Forced position ■ Various setpoints for forced position or emergency operation in case of bus failure for summer or winter ■ Cyclical monitoring of the input signals can be parameterised ■ Feedback via bus, e.g. in case of mains failure, overload or sensor failure Technical data Rated voltage: AC 110 ... 230 V ~, 50/60 Hz Stand-by power: max. 0.4 W Power loss: max. 1 W KNX medium: TP 256 Rated voltage KNX: DC 21 ... 32 V SELV Power consumption KNX: max. 250 mW Ambient temperature: −5 ... +45 °C Storage/transport temperature: −25 ... +70 °C Heating outputs Contact type: semiconductor (triac), ε Switching voltage: AC 24 / 230 V ~ Mains frequency: 50/60 Hz Switching current: 5 ... 160 mA Switch-on current: max. 1.5 A (2 s) Switch-on current: max. 0.3 A (2 min) Number of drives per output 230 V drives: max. 4 24 V drives: max. 2 Mounting width: 72 mm (4 rail units) Connection, outputs Connection mode: screw terminals single wire: 1 x 0.5 ... 4 mm2 stranded without ferrule: 1 x 0.5 ... 4 mm2 stranded with ferrule: 1 x 0.5 ... 2.5 mm2 Manufacturer: JUNG Ref.-no.: 2336 REG HZ HE

Technical data

ETIM class: Heating actuator for bus system (EC001586)

Communication

Bus system KNX
-
Bus system KNX-RF (Radio Frequency)
-
Bus system radio frequency
-
Bus system LON
-
Bus system Powernet
-
Other bus systems
-

Options

Radio frequency bidirectional
-
Bus module detachable
-
Correcting variable consistent
-
Correcting variable switching
-
Manual switch
-

Mounting/installation

Mounting method
-

Measurements

Width in number of modular spacings
4
Min. depth of built-in installation box
- mm
Number of binary inputs
-

Protection

Valve protection function
-
Degree of protection (IP)
IP20

Electrical

Max. switching current (resistive load)
- A
Max. output current
- A
Switching voltage
- V

Connection

Number of outputs
6

Logistics

Country of origin
Germany
Customs tariff number
85371098

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet1—0.285 kg95 × 96 × 77 mm

Documents