Skip to content
Eltracore
No photo yet

Jung

KNX hating actuator, 6-gang with controller

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Description

with controller Rail mounting device, 4 rail units 6 outputs "TRIAC" with manual electronic operation and LED status indication ETS product family: Heating, A/C, Ventilation Product type: Valve Intended use Switching of electrothermal actuators for heaters or cooling ceilings Installation in distribution boxes on DIN rail according to EN 60715   Product characteristics Integrated room temperature control with setpoint value specification Six independent controllers to control up to six independent rooms Controller function for heating and cooling Switching operation or PWM operation Actuators with characteristics "normally open" or "normally closed" can be controlled Valve drives for 230 V or 24 V controllable Outputs can be operated manually, construction site mode Feedback in manual mode and in bus mode Disabling of individual outputs manually or via bus Overload-protected, short circuit-protected; error indication with LED Protection against jamming valves Forced position Various setpoints for forced position or emergency operation in case of bus failure for summer or winter Cyclical monitoring of the input signals can be parameterised Feedback via bus, e.g. in case of mains failure, overload or sensor failure

Tender text

Heating actuator 6-gang with controller KNX heating actuator, 6-gang Intended use ■ Switching of electrothermal actuators for heaters or cooling ceilings ■ Installation in distribution boxes on DIN rail according to EN 60715 Product characteristics ■ Integrated room temperature control with setpoint value specification ■ Six independent controllers to control up to six independent rooms ■ Controller function for heating and cooling ■ Switching operation or PWM operation ■ Actuators with characteristics "normally open" or "normally closed" can be controlled ■ Valve drives for 230 V or 24 V controllable ■ Outputs can be operated manually, construction site mode ■ Feedback in manual mode and in bus mode ■ Disabling of individual outputs manually or via bus ■ Overload-protected, short circuit-protected; error indication with LED ■ Protection against jamming valves ■ Forced position ■ Various setpoints for forced position or emergency operation in case of bus failure for summer or winter ■ Cyclical monitoring of the input signals can be parameterised ■ Feedback via bus, e.g. in case of mains failure, overload or sensor failure Technical data Rated voltage: AC 110 ... 230 V ~, 50/60 Hz Stand-by power: max. 0.4 W Power loss: max. 1 W KNX medium: TP 256 Rated voltage KNX: DC 21 ... 32 V SELV Power consumption KNX: max. 250 mW Ambient temperature: −5 ... +45 °C Storage/transport temperature: −25 ... +70 °C Heating outputs Contact type: semiconductor (triac), ε Switching voltage: AC 24 / 230 V ~ Mains frequency: 50/60 Hz Switching current: 5 ... 160 mA Switch-on current: max. 1.5 A (2 s) Switch-on current: max. 0.3 A (2 min) Number of drives per output 230 V drives: max. 4 24 V drives: max. 2 Mounting width: 72 mm (4 rail units) Connection, outputs Connection mode: screw terminals single wire: 1 x 0.5 ... 4 mm2 stranded without ferrule: 1 x 0.5 ... 4 mm2 stranded with ferrule: 1 x 0.5 ... 2.5 mm2 Manufacturer: JUNG Ref.-no.: 2336 REG HZR HE

Technical data

ETIM class: Heating actuator for bus system (EC001586)

Communication

Bus system KNX
Yes
Bus system KNX-RF (Radio Frequency)
No
Bus system radio frequency
No
Bus system LON
No
Bus system Powernet
No
Other bus systems
-

Options

Radio frequency bidirectional
-
Bus module detachable
-
Correcting variable consistent
Yes
Correcting variable switching
Yes
Manual switch
Yes

Mounting/installation

Mounting method
DRA (DIN-rail adaptor)

Measurements

Width in number of modular spacings
4
Min. depth of built-in installation box
- mm

Connection

With bus connection
Yes
Number of outputs
6
Number of binary inputs
-

Protection

Valve protection function
Yes
Degree of protection (IP)
-

Electrical

Max. switching current (resistive load)
- A
Max. output current
- A
Switching voltage
24, 230 V

Logistics

Country of origin
Germany
Customs tariff number
85371098

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet1—0.282 kg95 × 96 × 77 mm

Documents