Description

New system feature: Fully-encrypted radio transmission (AES-CCM) from eNet Server software version 2.0 Intended use Energy sensor to determine energy values Sensor for load-dependent control of eNet actuators with eNet server Transfer of the measured values to the eNet server Operation with power supply (ref.-no. NT 1220 REG VDC) and receiver module (ref.-no. FM FK 32 REG) or eNet server Installation in distribution boxes on DIN rail according to EN 60715   Product characteristics Separate calculation of the active power and the active energy for each measuring channel Event or time-controlled transmission of measured value telegrams to the eNet server Fully-encrypted radio transmission (AES-CCM) from eNet Server software version 2.0 Update of the device software

Tender text

eNet radio energy detector 4-gang, for rail mounting eNet radio energy detector 4-gang, for rail mounting Intended use ■ Energy sensor to determine energy values ■ Sensor for load-dependent control of eNet actuators with eNet server ■ Transfer of the measured values to the eNet server ■ Operation with power supply (ref.-no. NT 1220 REG VDC) and receiver module (ref.-no. FM FK 32 REG) or eNet server ■ Installation in distribution boxes on DIN rail according to EN 60715 Product characteristics ■ Separate calculation of the active power and the active energy for each measuring channel ■ Event or time-controlled transmission of measured value telegrams to the eNet server ■ Fully-encrypted radio transmission (AES-CCM) from eNet Server software version 2.0 ■ Update of the device software Technical data Rated voltage: AC 230 V ~, 50/60 Hz Rated load current: 16 A Peak current (1 s): 80 A Peak current (1 min): 24 A Power consumption per channel: 225 mW Ambient temperature: −5 ... +45 °C Transmission interval: 1 ... 60 min Connection of load terminals: screw terminals single wire: 1 x 1.5 ... 4 mm2 stranded without ferrule: 1 x 0.75 ... 4 mm2 stranded with ferrule: 1 x 0.5 ... 2.5 mm2 Mounting width: 72 mm (4 rail units) Bus line Rated voltage: DC 12 V SELV Current consumption: 10 mA Connection bus: terminal Cable length: max. 3 m Measuring ranges per channel Current: 0 mA ... 16 A Accuracy (current): ± 0.5 % of the current value and ± 8 mA Voltage: 207 ... 250 V Accuracy (voltage): ± 0.5 % of the current value Transmitted power and energy values Active power: −4,000 ... 4,000 W Apparent power: 0 ... 4000 VA Reactive power: −4,000 ... 4,000 var Accuracy (power): ± 0.5 % of the current value and ± 2 W/VA/var Active energy: −99,999 ... 99,999 kWh Manufacturer: JUNG Ref.-no.: FM ES 36804 REG

Technical data

ETIM class: Energy management for bus system (EC001102)

Communication

Bus system KNX
No
Bus system KNX-RF (Radio Frequency)
No
Bus system radio frequency
Yes
Bus system LON
No
Bus system Powernet
No
Other bus systems
eNet
S0 impulse interface
-

Options

Radio frequency bidirectional
Yes
Reactive power
-
Tariff switch
-

Model/type

Model
Other

Connection

Connection type
-

Approval/certification

Approved according to PTB
-

Performance

Accuracy class
-

Measurements

Min. depth of built-in installation box
- mm

Logistics

Country of origin
Germany
Customs tariff number
85269200

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet1—0.228 kg110 × 77 × 77 mm