Skip to content
Eltracore
No photo yet

Jung

Room thermostat universal with display, AS/A range, white

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Description

Automatic control with programmable time and temperature settings possible with white illuminated display screw fixing only, without claws Delivery capacity is ensured until the end of March 2021.   Intended use Measurement and feedback control of the room temperature Measuring and controlling the floor temperature Room temperature control via floor heating with a limiting function (for example in conjunction with tiled stoves) Can be used for "heating only" or "cooling only" Installation in flush box according to DIN 49073 Only for use in dry, enclosed rooms   Product characteristics Large display with backlighting Text display for self-explanatory operation Programmable even when the controls are removed Different user languages can be selected Real-time clock with automatic summer/winter time changeover Internal temperature sensor An external remote sensor can be connected Three selectable and adjustable time temperature programs for automatic mode A maximum of nine operating times per day (the setting can also be terminated after a specific operating time) Can be individually programmed every day, or a block of operating times can be set: workdays/non-workdays, all days the same Can be manually adjusted at any time "Vacation" mode with the entered date (from/to) "At-home" mode (present) Short-time timer ("party function") Frost protection function Display of energy consumption for electric heating systems Pulse width modulation (PWM) or two-point control system Adjustable cycle time (PWM), hysteresis and minimum on/off time (two-point) Switch-on delay, such as for burners (with two-point control) Adaptation to valves normally open or normally closed) Valve protection (as a room temperature controller with and without a limiting function) Separate resetting of user and installer settings Heating interruption acc. to EN 50559 adjustable (not for valves opened without power)   The control method depends on the type of heating and is determined by the installer: Room temperature controller: The heating is turned on when the room temperature falls below the set target temperature (measured with an internal sensor or external remote sensor). Floor temperature controller: The underfloor heating is turned on when the floor temperature falls below the set target temperature (measured using an external remote sensor). Room temperature controller with a limiter (in conjunction with underfloor heating): The room temperature is measured and regulated using the internal sensor. An additional external remote sensor is connected to measure the floor temperature, and a target temperature range for the floor is set. The room temperature control is deactivated when the floor temperature is outside of this range. If temperature falls below this range, the heater is turned on, and if the temperature is above this range, the heater is turned off independent of the current room temperature.

Tender text

Room thermostat universal with display Room thermostat universal with display Thermoplastic (breakproof) high-gloss Delivery capacity is ensured until the end of March 2021. Intended use ■ Measurement and feedback control of the room temperature ■ Measuring and controlling the floor temperature ■ Room temperature control via floor heating with a limiting function (for example in conjunction with tiled stoves) ■ Can be used for "heating only" or "cooling only" ■ Installation in flush box according to DIN 49073 ■ Only for use in dry, enclosed rooms Product characteristics ■ Large display with backlighting ■ Text display for self-explanatory operation ■ Programmable even when the controls are removed ■ Different user languages can be selected ■ Real-time clock with automatic summer/winter time changeover ■ Internal temperature sensor ■ An external remote sensor can be connected ■ Three selectable and adjustable time temperature programs for automatic mode ■ A maximum of nine operating times per day (the setting can also be terminated after a specific operating time) ■ Can be individually programmed every day, or a block of operating times can be set: workdays/non-workdays, all days the same ■ Can be manually adjusted at any time ■ "Vacation" mode with the entered date (from/to) ■ "At-home" mode (present) ■ Short-time timer ("party function") ■ Frost protection function ■ Display of energy consumption for electric heating systems ■ Pulse width modulation (PWM) or two-point control system ■ Adjustable cycle time (PWM), hysteresis and minimum on/off time (two-point) ■ Switch-on delay, such as for burners (with two-point control) ■ Adaptation to valves normally open or normally closed) ■ Valve protection (as a room temperature controller with and without a limiting function) ■ Separate resetting of user and installer settings ■ Heating interruption acc. to EN 50559 adjustable (not for valves opened without power) The control method depends on the type of heating and is determined by the installer: Room temperature controller: The heating is turned on when the room temperature falls below the set target temperature (measured with an internal sensor or external remote sensor). Floor temperature controller: The underfloor heating is turned on when the floor temperature falls below the set target temperature (measured using an external remote sensor). Room temperature controller with a limiter (in conjunction with underfloor heating): The room temperature is measured and regulated using the internal sensor. An additional external remote sensor is connected to measure the floor temperature, and a target temperature range for the floor is set. The room temperature control is deactivated when the floor temperature is outside of this range. If temperature falls below this range, the heater is turned on, and if the temperature is above this range, the heater is turned off independent of the current room temperature. Technical data Rated voltage: AC 230 V ~, 50 Hz, neutral conductor required Output: relay (NO contact) Switching current as room temperature controller: 10 mA ... 10 (4) A, 230 V ~ as floor temperature controller: 10 mA ... 16 (4) A, 230 V ~ Power consumption: approx. 1.2 W Ambient temperature: 0 ... +40 °C (no condensation) Storing temperature: −20 ... +70 °C (no condensation) Temperature setting range: in increments of 0.5 °C as room temperature controller: 5 ... 30 °C as floor temperature controller: 10 ... 40 °C Temperature indication: in increments of 0.1 °C Output signal: pulse width modulation (PWM) or two-point control (on/off) PWM cycle time: adjustable (10 ... 30 min) Hysteresis: adjustable (with two-point control) Minimum switching time: adjustable (1 ... 30 min) Power reserve: approx. 10 years (lithium cell) Material: thermoplastic Colour: white Manufacturer: JUNG Ref.-no.: TR UD A 231 WW

Technical data

ETIM class: Room thermostat (EC010927)

Model/type

Model
Brand-dependent
With receiver
No
External sensor
No
Thermal feedback
-
With sound indicator
No
Sensor/feeler type
Bimetal
Number of modules (module system)
-
With display
Yes
With tap water circuit
No

Electrical

Type of power supply
230 V AC
Max. contact voltage
- V
Max. contact load
- A
Standby power consumption (solstandby)
- W

Connection

Connection
Two-wire
Control characteristic
-
Number of heater outputs
1
Number of cooler outputs
1
Measuring range minimum value
5.0
Measuring range maximum value
30.0
Heating
true
Cooling
true
Contact type
Normally open contact

Other

Differential value
0.5, 0.5 K

Setting/control

Adjustable differential
No
Operation
Button
Class of the temperature control
-

Options

Temperature readable
Yes

Mounting/installation

Mounting method
Flush-mounted

Protection

Degree of protection (IP)
IP31
Degree of protection (NEMA)
-
Explosion-proof
-

Colour

Colour
-
RAL-number
-

Measurements

Height
55 mm
Width
55 mm
Depth
- mm
Diameter
- mm

Logistics

Country of origin
Germany
Customs tariff number
90321080

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet1—0.21 kg80 × 80 × 90 mm
carton10—2.27 kg430 × 170 × 100 mm

Documents