Description
Automatic control with programmable time and temperature settings possible with white illuminated display screw fixing only, without claws Delivery capacity is ensured until the end of March 2021. Intended use Measurement and feedback control of the room temperature Measuring and controlling the floor temperature Room temperature control via floor heating with a limiting function (for example in conjunction with tiled stoves) Can be used for "heating only" or "cooling only" Installation in flush box according to DIN 49073 Only for use in dry, enclosed rooms Product characteristics Large display with backlighting Text display for self-explanatory operation Programmable even when the controls are removed Different user languages can be selected Real-time clock with automatic summer/winter time changeover Internal temperature sensor An external remote sensor can be connected Three selectable and adjustable time temperature programs for automatic mode A maximum of nine operating times per day (the setting can also be terminated after a specific operating time) Can be individually programmed every day, or a block of operating times can be set: workdays/non-workdays, all days the same Can be manually adjusted at any time "Vacation" mode with the entered date (from/to) "At-home" mode (present) Short-time timer ("party function") Frost protection function Display of energy consumption for electric heating systems Pulse width modulation (PWM) or two-point control system Adjustable cycle time (PWM), hysteresis and minimum on/off time (two-point) Switch-on delay, such as for burners (with two-point control) Adaptation to valves normally open or normally closed) Valve protection (as a room temperature controller with and without a limiting function) Separate resetting of user and installer settings Heating interruption acc. to EN 50559 adjustable (not for valves opened without power) The control method depends on the type of heating and is determined by the installer: Room temperature controller: The heating is turned on when the room temperature falls below the set target temperature (measured with an internal sensor or external remote sensor). Floor temperature controller: The underfloor heating is turned on when the floor temperature falls below the set target temperature (measured using an external remote sensor). Room temperature controller with a limiter (in conjunction with underfloor heating): The room temperature is measured and regulated using the internal sensor. An additional external remote sensor is connected to measure the floor temperature, and a target temperature range for the floor is set. The room temperature control is deactivated when the floor temperature is outside of this range. If temperature falls below this range, the heater is turned on, and if the temperature is above this range, the heater is turned off independent of the current room temperature.
Tender text
Room thermostat universal with display Room thermostat universal with display Thermoplastic (breakproof) high-gloss Delivery capacity is ensured until the end of March 2021. Intended use ■ Measurement and feedback control of the room temperature ■ Measuring and controlling the floor temperature ■ Room temperature control via floor heating with a limiting function (for example in conjunction with tiled stoves) ■ Can be used for "heating only" or "cooling only" ■ Installation in flush box according to DIN 49073 ■ Only for use in dry, enclosed rooms Product characteristics ■ Large display with backlighting ■ Text display for self-explanatory operation ■ Programmable even when the controls are removed ■ Different user languages can be selected ■ Real-time clock with automatic summer/winter time changeover ■ Internal temperature sensor ■ An external remote sensor can be connected ■ Three selectable and adjustable time temperature programs for automatic mode ■ A maximum of nine operating times per day (the setting can also be terminated after a specific operating time) ■ Can be individually programmed every day, or a block of operating times can be set: workdays/non-workdays, all days the same ■ Can be manually adjusted at any time ■ "Vacation" mode with the entered date (from/to) ■ "At-home" mode (present) ■ Short-time timer ("party function") ■ Frost protection function ■ Display of energy consumption for electric heating systems ■ Pulse width modulation (PWM) or two-point control system ■ Adjustable cycle time (PWM), hysteresis and minimum on/off time (two-point) ■ Switch-on delay, such as for burners (with two-point control) ■ Adaptation to valves normally open or normally closed) ■ Valve protection (as a room temperature controller with and without a limiting function) ■ Separate resetting of user and installer settings ■ Heating interruption acc. to EN 50559 adjustable (not for valves opened without power) The control method depends on the type of heating and is determined by the installer: Room temperature controller: The heating is turned on when the room temperature falls below the set target temperature (measured with an internal sensor or external remote sensor). Floor temperature controller: The underfloor heating is turned on when the floor temperature falls below the set target temperature (measured using an external remote sensor). Room temperature controller with a limiter (in conjunction with underfloor heating): The room temperature is measured and regulated using the internal sensor. An additional external remote sensor is connected to measure the floor temperature, and a target temperature range for the floor is set. The room temperature control is deactivated when the floor temperature is outside of this range. If temperature falls below this range, the heater is turned on, and if the temperature is above this range, the heater is turned off independent of the current room temperature. Technical data Rated voltage: AC 230 V ~, 50 Hz, neutral conductor required Output: relay (NO contact) Switching current as room temperature controller: 10 mA ... 10 (4) A, 230 V ~ as floor temperature controller: 10 mA ... 16 (4) A, 230 V ~ Power consumption: approx. 1.2 W Ambient temperature: 0 ... +40 °C (no condensation) Storing temperature: −20 ... +70 °C (no condensation) Temperature setting range: in increments of 0.5 °C as room temperature controller: 5 ... 30 °C as floor temperature controller: 10 ... 40 °C Temperature indication: in increments of 0.1 °C Output signal: pulse width modulation (PWM) or two-point control (on/off) PWM cycle time: adjustable (10 ... 30 min) Hysteresis: adjustable (with two-point control) Minimum switching time: adjustable (1 ... 30 min) Power reserve: approx. 10 years (lithium cell) Material: thermoplastic Colour: ivory Manufacturer: JUNG Ref.-no.: TR UD LS 231
Technical data
ETIM class: Room thermostat (EC010927)
Model/type
- Model
- Brand-dependent
- With receiver
- No
- External sensor
- No
- Thermal feedback
- -
- With sound indicator
- No
- Sensor/feeler type
- Bimetal
- Number of modules (module system)
- -
- With display
- Yes
- With tap water circuit
- No
Electrical
- Type of power supply
- 230 V AC
- Max. contact voltage
- - V
- Max. contact load
- - A
- Standby power consumption (solstandby)
- - W
Connection
- Connection
- Two-wire
- Control characteristic
- -
- Number of heater outputs
- 1
- Number of cooler outputs
- 1
- Measuring range minimum value
- 5.0
- Measuring range maximum value
- 30.0
- Heating
- true
- Cooling
- true
- Contact type
- Normally open contact
Other
- Differential value
- 0.5, 0.5 K
Setting/control
- Adjustable differential
- No
- Operation
- Button
- Class of the temperature control
- -
Options
- Temperature readable
- Yes
Mounting/installation
- Mounting method
- Flush-mounted
Protection
- Degree of protection (IP)
- IP31
- Degree of protection (NEMA)
- -
- Explosion-proof
- -
Colour
- Colour
- Cream-white
- RAL-number
- -
Measurements
- Height
- 70 mm
- Width
- 70 mm
- Depth
- - mm
- Diameter
- - mm
Logistics
- Country of origin
- Germany
- Customs tariff number
- 90321080
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| packet | 10 | — | 2.08 kg | 420 × 170 × 98 mm |