Skip to content
Eltracore

Legrand

KNX CABLE BUS 500 M.

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Technical data

ETIM class: Power cable >= 1 kV, for permanent installation (EC003251)

Circuit integrity according to IEC 60331-3
-
Insulation integrity
-
Circuit integrity according to IEC 60331-21
-
Insulation integrity according to IEC 60331
-
Flame retardant according to EN 60332-1-2
-
Flame retardant according to EN 60332-3-21 (Cat A F/R)
-
Circuit integrity according to EN 50200
-
Circuit integrity according to EN 50200 annex E
-
Low smoke (according to EN 61034-2)
true
Nominal cross section pilot/reduced conductor
-
Halogen free according to EN 60754-1/2
false
Oil resistant (according to IEC 60811-404)
-
Flame retardant according to EN 60332-3-22 (Cat A)
-
Flame retardant according to EN 60332-3-23 (Cat B)
-
Flame retardant according to EN 60332-3-24 (Cat C)
-
Flame retardant according to EN 60332-3-25 (Cat D)
-
Halogen free according to EN 60754-1
-
Halogen free according to EN 60754-2
-
Halogen free according to EN 60754-3
-

Material

Conductor material
Copper
Conductor surface
Bare
Material core insulation
Other
Material armouring
-
Material outer sheath
Other
Specification material outer sheath
Other
Low smoke according to EN IEC 61034-2
Yes
Halogen free according to EN IEC 60754-1
Yes
Halogen free according to EN IEC 60754-2
Yes
Halogen free according to EN IEC 60754-3
-

Connection

Nominal cross section conductor
0.8 mm²
Nominal cross section conductor (AWG)
- kcmil
Nominal cross section pilot/reduced conductors
- mm²
Nominal cross section pilot/reduced conductors (AWG)
-
Nominal cross section concentric conductor
0.5 mm²

Measurements

AWG size
-
Diameter conductor
0.5 mm
Strand diameter
- mm
Cable width approximate
5.5 mm
Cable height approximate
5.5 mm
Outer diameter approximate
5.5 mm
Min. permitted bending radius, stationary application/permanent installation
- mm
Weight
- kg/km

Other

Conductor category
Class 2 = stranded
Specification core insulation
-
Core identification
Colour
Armouring/reinforcement
-
Concentric conductor
Copper
Nominal equivalent cross section of reinforcement
- mm²

Model/type

Number of strands per conductor
1
Shape of conductor
Round
Number of cores
2
With protective conductor
No
Number of pilot/reduced conductors
0
Cable geometry
Round
Suitable as installation cable
Yes
With rodent protection
-

Electrical

Conductor resistance at 20 °C
10000 Ohm/km
Nominal voltage U0
2.5 kV
Nominal voltage U
4 kV

Options

Core identification according to HD 308 S2
-
Laminated sheath
Yes
Fibre optic elements
No
Inner semi-conducting layer
-
Outer semi-conducting layer
-
Screen
Yes
Armouring
false
Drain wire
Yes
Lead sheath
No
Conductive coating
-
Circuit integrity according to EN 50200 annex E
-

Protection

Protective barrier
-
Radial water blocking cable
-
Circuit integrity
-
Longitudinal water blocking conductors
-
Longitudinal water blocking screen
-
Flame retardant according to IEC 60332-1-2
-
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
-
Flame retardant according to IEC 60332-3-22 (Cat A)
-
Flame retardant according to IEC 60332-3-23 (Cat B)
-
Flame retardant according to IEC 60332-3-24 (Cat C)
-
Flame retardant according to IEC 60332-3-25 (Cat D)
-
Reaction-to-fire according to EN 13501-6: Class
-
Reaction-to-fire according to EN 13501-6: Smoke production
-
Flame retardant
No
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
-
Reaction-to-fire according to EN 13501-6: Acidity
-
Oil resistant according to EN IEC 60811-404
-
Insulation integrity according to DIN VDE 0472-814
-
Circuit integrity according to DIN 4102-12
-
Circuit integrity according to BS 6387 CWZ
-
Circuit integrity according to BS 8434-2
-
Circuit integrity according to BS 8491
-

Colour

Colour outer sheath
Green

Approval/certification

Circuit integrity according to IEC 60331-1
-
Circuit integrity according to IEC 60331-2
-
Circuit integrity according to IEC 60331-3
-
Circuit integrity according to EN 50200
-
Certified as airport lighting cable
-

Mounting/installation

Max. tensile strength during installation
- kN
Suitable for underground installation
No

Operating conditions

Max. permitted conductor temperature
- °C
Permitted cable outer temperature during assembling/handling
-25, 70 °C
Permitted cable outer temperature after assembling without vibration
-25, 70 °C

Application

Certified for shipboard application
-
Suitable as medium-voltage cable
-
Suitable as high-voltage cable
-

Logistics

Country of origin
Germany
Customs tariff number
85444920

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
carton1324506049291518.4 kg342 × 400 × 400 mm
PF183414971157163331.2 kg1,180 × 1,200 × 1,000 mm

Documents