KNX CABLE BUS 500 M.
- Manufacturer part no.
- EAN
- Series
- Lighting management KNX
Price on requestAsk us for a quote for this product.
Ordering
- Order unit
- piece
Technical data
ETIM class: Power cable >= 1 kV, for permanent installation (EC003251)
- Circuit integrity according to IEC 60331-3
- -
- Insulation integrity
- -
- Circuit integrity according to IEC 60331-21
- -
- Insulation integrity according to IEC 60331
- -
- Flame retardant according to EN 60332-1-2
- -
- Flame retardant according to EN 60332-3-21 (Cat A F/R)
- -
- Circuit integrity according to EN 50200
- -
- Circuit integrity according to EN 50200 annex E
- -
- Low smoke (according to EN 61034-2)
- true
- Nominal cross section pilot/reduced conductor
- -
- Halogen free according to EN 60754-1/2
- false
- Oil resistant (according to IEC 60811-404)
- -
- Flame retardant according to EN 60332-3-22 (Cat A)
- -
- Flame retardant according to EN 60332-3-23 (Cat B)
- -
- Flame retardant according to EN 60332-3-24 (Cat C)
- -
- Flame retardant according to EN 60332-3-25 (Cat D)
- -
- Halogen free according to EN 60754-1
- -
- Halogen free according to EN 60754-2
- -
- Halogen free according to EN 60754-3
- -
Material
- Conductor material
- Copper
- Conductor surface
- Bare
- Material core insulation
- Other
- Material armouring
- -
- Material outer sheath
- Other
- Specification material outer sheath
- Other
- Low smoke according to EN IEC 61034-2
- Yes
- Halogen free according to EN IEC 60754-1
- Yes
- Halogen free according to EN IEC 60754-2
- Yes
- Halogen free according to EN IEC 60754-3
- -
Connection
- Nominal cross section conductor
- 0.8 mm²
- Nominal cross section conductor (AWG)
- - kcmil
- Nominal cross section pilot/reduced conductors
- - mm²
- Nominal cross section pilot/reduced conductors (AWG)
- -
- Nominal cross section concentric conductor
- 0.5 mm²
Measurements
- AWG size
- -
- Diameter conductor
- 0.5 mm
- Strand diameter
- - mm
- Cable width approximate
- 5.5 mm
- Cable height approximate
- 5.5 mm
- Outer diameter approximate
- 5.5 mm
- Min. permitted bending radius, stationary application/permanent installation
- - mm
- Weight
- - kg/km
Other
- Conductor category
- Class 2 = stranded
- Specification core insulation
- -
- Core identification
- Colour
- Armouring/reinforcement
- -
- Concentric conductor
- Copper
- Nominal equivalent cross section of reinforcement
- - mm²
Model/type
- Number of strands per conductor
- 1
- Shape of conductor
- Round
- Number of cores
- 2
- With protective conductor
- No
- Number of pilot/reduced conductors
- 0
- Cable geometry
- Round
- Suitable as installation cable
- Yes
- With rodent protection
- -
Electrical
- Conductor resistance at 20 °C
- 10000 Ohm/km
- Nominal voltage U0
- 2.5 kV
- Nominal voltage U
- 4 kV
Options
- Core identification according to HD 308 S2
- -
- Laminated sheath
- Yes
- Fibre optic elements
- No
- Inner semi-conducting layer
- -
- Outer semi-conducting layer
- -
- Screen
- Yes
- Armouring
- false
- Drain wire
- Yes
- Lead sheath
- No
- Conductive coating
- -
- Circuit integrity according to EN 50200 annex E
- -
Protection
- Protective barrier
- -
- Radial water blocking cable
- -
- Circuit integrity
- -
- Longitudinal water blocking conductors
- -
- Longitudinal water blocking screen
- -
- Flame retardant according to IEC 60332-1-2
- -
- Flame retardant according to IEC 60332-3-21 (Cat A F/R)
- -
- Flame retardant according to IEC 60332-3-22 (Cat A)
- -
- Flame retardant according to IEC 60332-3-23 (Cat B)
- -
- Flame retardant according to IEC 60332-3-24 (Cat C)
- -
- Flame retardant according to IEC 60332-3-25 (Cat D)
- -
- Reaction-to-fire according to EN 13501-6: Class
- -
- Reaction-to-fire according to EN 13501-6: Smoke production
- -
- Flame retardant
- No
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- -
- Reaction-to-fire according to EN 13501-6: Acidity
- -
- Oil resistant according to EN IEC 60811-404
- -
- Insulation integrity according to DIN VDE 0472-814
- -
- Circuit integrity according to DIN 4102-12
- -
- Circuit integrity according to BS 6387 CWZ
- -
- Circuit integrity according to BS 8434-2
- -
- Circuit integrity according to BS 8491
- -
Colour
- Colour outer sheath
- Green
Approval/certification
- Circuit integrity according to IEC 60331-1
- -
- Circuit integrity according to IEC 60331-2
- -
- Circuit integrity according to IEC 60331-3
- -
- Circuit integrity according to EN 50200
- -
- Certified as airport lighting cable
- -
Mounting/installation
- Max. tensile strength during installation
- - kN
- Suitable for underground installation
- No
Operating conditions
- Max. permitted conductor temperature
- - °C
- Permitted cable outer temperature during assembling/handling
- -25, 70 °C
- Permitted cable outer temperature after assembling without vibration
- -25, 70 °C
Application
- Certified for shipboard application
- -
- Suitable as medium-voltage cable
- -
- Suitable as high-voltage cable
- -
Logistics
- Country of origin
- Germany
- Customs tariff number
- 85444920
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| carton | 1 | 3245060492915 | 18.4 kg | 342 × 400 × 400 mm |
| PF | 18 | 3414971157163 | 331.2 kg | 1,180 × 1,200 × 1,000 mm |