Skip to content
Eltracore

Schneider Electric

Schneider Electric Acti9 iC60N A9F74463 MCB 4P 63 A Curve C

Manufacturer part no.
EAN
Guest price€70.93 / pcexcl. VATMinimum order 1Sign in to see your personal price

Ordering

Order unit
piece

Description

The Schneider Electric Acti9 iC60N A9F74463 is a low-voltage miniature circuit breaker (MCB) that protects circuits against short circuits and overloads. It has a 4P configuration with 4 protected poles, a rated current of 63 A and a C trip curve. Under EN/IEC 60947-2, the ultimate short-circuit breaking capacity (Icu) is 20 kA at 220 to 240 V AC and 10 kA at 380 to 415 V AC. Under EN/IEC 60898-1, the rated short-circuit breaking capacity (Icn) is 6000 A at 400 V AC. The VisiTrip indicator identifies the circuit that has tripped, shortening response time. The green VisiSafe strip confirms that the contacts are physically open for downstream maintenance. The quick-closing mechanism operates independently of manual actuation and helps extend service life. Electrical endurance is up to 10 000 cycles and mechanical endurance is up to 20 000 cycles. The rated insulation voltage Ui is 500 V AC. The breaker has a current limiting class of 3 under EN/IEC 60898-1, a pollution degree of 3 and an overvoltage category of IV. It clips onto a DIN rail and occupies 8 pitches of 9 mm. It is white (RAL9003), measures 72 mm wide × 85 mm high × 78.5 mm deep and weighs 0.5 kg. Under IEC 60529, its degree of protection is IP20, or IP40 in an enclosure. The operating temperature range is -35 °C to 70 °C and the storage temperature range is -40 °C to 85 °C.

Technical data

ETIM class: Miniature circuit breaker (MCB) (EC000042)

Measurements

Built-in depth
44.5 mm
Width in number of modular spacings
4

Electrical

Release characteristic
C
Rated current
63 A
Rated voltage
400 V
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
6 kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
NA kA
Voltage type
AC/DC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
6 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
20 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
10 kA
Power loss
5.6 W
Current limiting class
3
Overvoltage category
4

Model/type

Number of poles (total)
4
Number of protected poles
4

Other

Frequency
50, 60 Hz
Pollution degree
3

Mounting/installation

Flush-mounted installation
No

Options

Concurrently switching neutral conductor
No
Additional equipment possible
Yes

Protection

Degree of protection (IP)
IP20
Explosion-proof
No

Operating conditions

Ambient temperature during operating
-35, 70 °C

Connection

Connectable conductor cross section multi-wired
1, 25 mm²
Connectable conductor cross section solid-core
1, 35 mm²

Logistics

Country of origin
France
Customs tariff number
8536201090

Documents